1. Review on Seismic Rehabilitation of a 56-Story RC Tall Building having Shear Wall System Based on A Nonlinear Dynamic Performance Evaluation.
- Author
-
Epackachi, S., Esmaili, O., Mirghaderi, S. R., and Taheri, A. A.
- Subjects
- *
EFFECT of earthquakes on buildings , *TALL buildings , *RETROFITTING , *SHEAR walls , *WALL panels , *SAFETY - Abstract
Tehran tower is a 56 story reinforced concrete tall building consisting of three wings with identical plan dimensions each approximately 48 meters by 22 meters. The three wings are at 120 degree from each other and have no expansions/seismic Joints. This paper contains the consideration of the retrofitting of the Tehran tower based on the findings of an exhaustive investigation of the nonlinear performance evaluation efforts. It has tried to show the procedure followed, methodologies utilized, and the results obtained for life-safety and collapse-prevention evaluation of the building. More over the weak zones of the structure due to analysis results are introduced and appropriate retrofit technique for satisfaction related life-safety and collapse-prevention criteria is presented. Actually in this project to improve the local behavior of coupling panels which are located regularly in main walls and definitely have been recognized as the most vulnerable structural elements, making use of steel plates which are connected to concrete members by chemical anchors has been used as the best retrofitting method for this case. Therefore in the final section of this paper it has been tried to explain the professional practical method utilized to perform the mentioned retrofitting project. [ABSTRACT FROM AUTHOR]
- Published
- 2008
- Full Text
- View/download PDF