1. The adverse effects of gas-burning CHP systems on the local air quality.
- Author
-
Jazaeri, Javad and Pahlevani, Mahdi
- Subjects
- *
GREENHOUSE gases , *EMISSIONS (Air pollution) , *GAUSSIAN processes , *AIR quality , *TRIGENERATION (Energy) - Abstract
One of the benefits of the combined heat and power (CHP) systems is reducing greenhouse gases (GHG) in the national level. These systems are installed in the close vicinity of local communities and their pollution can directly affect the local environment. This paper studies the adverse environmental effects of a 2 MW gas-burning CHP (GB-CHP) system in a residential community in Mashhad, Iran. We compare the amount of C O 2 and N O x emissions from the GB-CHP with the conventional choice of supplying electricity from the central power plants and heat from the locally installed boilers. The results show that the GB-CHP system increases local C O 2 and N O x emissions by approximately two and six times, respectively. The N O x emission is increased from 3.1 tonnes to 18.7 tonnes. The C O 2 emission increases from 3623 tonnes to 7238 tonnes. Furthermore, we use Gaussian Dispersion model to estimate the concentration of these emissions in the local area using the weather conditions of the most polluted times of the previous year. The results show that for a 3-meter stack, the maximum concentration of C O 2 and N O x are 14.8 m g / m 3 and 38.1 μ g / m 3 , respectively. Our analysis shows that increasing the height of the GB-CHP stack from 3 meters to 10 meters reduces the concentration by 40%. [ABSTRACT FROM AUTHOR]
- Published
- 2018
- Full Text
- View/download PDF