1. The Photon-Counting CT Enters the Field of Cochlear Implantation: Comparison to Angiography DynaCT and Conventional Multislice CT.
- Author
-
Rak K, Spahn B, Müller-Graff FT, Engert J, Voelker J, Hackenberg S, Hagen R, Petritsch B, Grunz JP, Bley T, Neun T, and Huflage H
- Subjects
- Humans, Cochlear Duct diagnostic imaging, Cochlear Duct surgery, Tomography, X-Ray Computed methods, Cochlear Implants, Photons, Petrous Bone diagnostic imaging, Petrous Bone surgery, Multidetector Computed Tomography methods, Angiography methods, Cochlear Implantation methods
- Abstract
Introduction: Cochlear duct length (CDL) measurement plays a role in the context of individualized cochlear implant (CI) surgery regarding an individualized selection and implantation of the CI electrode carrier and an efficient postoperative anatomy-based fitting process. The level of detail of the preoperative temporal bone CT scan depends on the imaging modality with major impact on CDL measurements and CI electrode contact position determination. The aim of this study was to evaluate the accuracy of perioperative CDL measurements and electrode contact determination in photon-counting CT (PCCT)., Methods: Ten human fresh-frozen petrous bone specimens were examined with a first-generation PCCT. A clinically applicable radiation dose of 27.1 mGy was used. Scans were acquired before and after CI insertion. Postoperative measurement of the CDL was conducted using an otological planning software and 3D-curved multiplanar reconstruction. Investigation of electrode contact position was performed by two respective observers. Measurements were compared with a conventional multislice CT and to a high-resolution flat-panel volume CT with secondary reconstructions., Results: Pre- and postoperative CDL measurements in PCCT images showed no significant difference to high-resolution flat-panel volume CT. Postoperative CI electrode contact determination was also as precise as the flat-panel CT-based assessment. PCCT and flat-panel volume CT were equivalent concerning interobserver variability., Conclusion: CDL measurement with PCCT was equivalent to flat-panel volume CT with secondary reconstructions. PCCT enabled highly precise postoperative CI electrode contact determination with substantial advantages over conventional multislice CT scanners., Competing Interests: The authors disclose no conflicts of interest., (Copyright © 2024, Otology & Neurotology, Inc.)
- Published
- 2024
- Full Text
- View/download PDF