1. Reliability and reference values for diaphragmatic excursion, thickness, and thickening fraction and quadriceps femoris muscle thickness in full-term newborns evaluated by ultrasound.
- Author
-
Nascimento MS, Leite FS, Silva PAL, Zamberlan GC, de Souza PM, Eid RAC, Zacharias RSB, do Prado C, and Batista CL
- Subjects
- Humans, Infant, Newborn, Prospective Studies, Reproducibility of Results, Male, Female, Reference Values, Observer Variation, Gestational Age, Diaphragm diagnostic imaging, Quadriceps Muscle diagnostic imaging, Quadriceps Muscle anatomy & histology, Ultrasonography methods
- Abstract
To determine the diaphragm thickness, thickening fraction, and excursion and thickness of the quadriceps femoris muscle in full-term newborns and to evaluate the intra- and interrater reliability of these measurements. This was a prospective, observational clinical study including full-term newborns born within the first 48 h after birth. Serial measurements of the thickness, thickening fraction, and mobility of the diaphragm muscles and the thickness of the quadriceps muscle were obtained using ultrasound images. A total of 69 newborns with a mean gestational age of 39 weeks were included. The following measurements were obtained and are expressed as the mean (standard deviation): inspiratory diaphragm thickness, 0.19 cm (0.04); expiratory diaphragm thickness, 0.16 cm (0.04); diaphragm thickness fraction, 16.70 cm (10.27); diaphragmatic excursion, 0.68 cm (0.22); and quadriceps thickness, 0.99 cm (0.14). Intrarater reliability was assessed using intraclass correlation coefficients (ICCs). Excellent intrarater agreement was observed for the two groups of operators (ICC > 0.86, p < 0.001) for all measurements except for the diaphragm thickening fraction, which showed good agreement for both operator groups (ICC = 0.70, p < 0.001). Regarding interrater reliability, moderate agreement between the raters was observed in the means of all measures (ICC > 0.49, p < 0.001), except for the diaphragm thickening fraction, which showed poor agreement. Conclusion: Good intrarater and moderate interrater reliability were achieved in ultrasound evaluations of the thickness and mobility of the diaphragm and quadriceps femoris muscles in full-term newborns, demonstrating the feasibility of this technique for clinical use. This pioneering study offers reference values for these muscles in a single study, allowing comparisons between different clinical conditions. What is Known: • Ultrasound is a highly reliable tool for muscle assessment that can be used to assess muscular atrophy in critically ill patients. • Muscle atrophy worsens the patient's condition and has been associated with worse outcomes. What is New: • To our knowledge, this is the first study to jointly evaluate the diaphragm and quadriceps muscle thickness and evaluate the reliability of all measurements. • Our study presents reference values for both muscles, enabling comparisons between different clinical conditions., (© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
- Published
- 2024
- Full Text
- View/download PDF