1. PRAĆENJE POTPOVRŠINSKE TEMPERATURE ZA UPORABU KOAKSIJALNIH GEOTERMALNIH IZMJENJIVAČA – PRAKTIČNI ASPEKTI I GLAVNI PROBLEMI U PRVIM GODINAMA MJERENJA
- Author
-
Francesco Tinti, Andrea Carri, Sara Kasmaee, Alessandro Valletta, Andrea Segalini, Stefano Bonduà, Villiam Bortolotti, Francesco Tinti, Andrea Carri, Sara Kasmaee, Alessandro Valletta, Andrea Segalini, Stefano Bonduà, and Villiam Bortolotti
- Abstract
Plitka, potpovršinska, temperatura (na dubinama plićim od 50 m) nije konstantna, niti u prostoru, niti vremenu. Takve promjene posljedica su utjecaja toplinskih „pulseva” različitoga podrijetla poput Sunčeva, geotermalnoga ili ljudskoga. Točna procjena temperature ključni je čimbenik kod planiranja energetskih sustava temeljenih na plitkoj geotermalnoj energiji. U takvim projektima, temeljenim na izmjenjivačima topline u plitkim bušotinama, potpovršinska je temperatura promjenjivija, što utječe na iznos pridobivanja topline, tj. utiskivanja fluida. Praćenje takvih promjena važno je stoga kod svih projekata toplinskih izmjenjivača vezanih uz plitka geotermalna ležišta. U radu je prikazan praktičan oblik toga, ali i glavni problemi koje je moguće susresti tijekom instaliranja, testiranja ili uporabe potrebne geotermalne opreme. Dan je primjer polja u kojemu je smješteno osam koaksijalnih izmjenjivača topline, 30 metara dugačkih te povezanih s prototipom uređaja dvostruke toplinske crpke (zračne i dubinske)., Ground temperature at shallow depth (< 50 m) is not stable, nor in space, neither in time, and its behaviour is the result of superimposition of effects of heat pulses of different origin: solar, geothermal and anthropic. The correct assessment of ground temperature is a crucial point when designing a shallow geothermal energy system. In geothermal closed loop projects, more the borehole heat exchangers are short, more the contribution of the ground temperature variability on the heat exchange is prominent. Monitoring ground temperature can be very useful to correctly understand the behaviour of a shallow geothermal reservoir subjected to heat extraction and/or injection by a ground source heat pump system. The present work illustrates the practical aspects and main issues occurred in the installation, testing and working phases of a monitoring system realised to record ground temperature in a geothermal application. The case study is a field of eight coaxial borehole heat exchangers, 30 m long, connected to a novel prototype of dual source (air and ground) heat pump.
- Published
- 2018