6 results on '"S. Kaufmann"'
Search Results
2. Dose Optimization of Perfusion-derived Response Assessment in Hepatocellular Carcinoma Treated with Transarterial Chemoembolization: Comparison of Volume Perfusion CT and Iodine Concentration.
- Author
-
Thaiss WM, Haberland U, Kaufmann S, Hepp T, Schulze M, Blum AC, Ketelsen D, Nikolaou K, Horger M, and Sauter AW
- Subjects
- Aged, Aged, 80 and over, Contrast Media, Female, Humans, Iodine, Male, Middle Aged, Perfusion Imaging methods, ROC Curve, Regional Blood Flow, Response Evaluation Criteria in Solid Tumors, Retrospective Studies, Carcinoma, Hepatocellular therapy, Chemoembolization, Therapeutic methods, Cone-Beam Computed Tomography methods, Liver Neoplasms therapy
- Abstract
Rationale and Objectives: We assessed the value of iodine concentration (IC) as a perfusion-derived response marker for hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) in comparison with volume perfusion computed tomography (VPCT) parameters., Materials and Methods: Forty-one HCC lesions in 32 patients examined before and after TACE were analyzed retrospectively. VPCT-parameters were calculated and lesion iodine-maps were computed using subtraction of the baseline and the scan 7 seconds after aortic peak enhancement from the corresponding 80 kVp-VPCT data set. Modified RECIST was used as standard response criteria. Comparisons were performed using Student's t test for normal distributed data and Mann-Whitney U test for non-normal distributed data. Additionally, correlation analysis, receiver operating characteristics (ROC) and interreader agreement were assessed., Results: In responding lesions, mean pre-TACE IC and blood flow (BF) were 131.2 mg/100 mL and 96.7 mL/100 mL/min, decreasing to IC 25.6 mg/100 mL (P < 0.001) and BF 28.5 mL/100 mL/min (P < 0.001) post-TACE. In nonresponding lesions, the values remained almost unchanged: pre-TACE: mean BF 79.3 mL/100 mL/min and mean IC 90.4 mg/100 mL; post-TACE: mean BF 71.3 mL/100 mL/min (n.s.) and mean IC 105.4 mg/100 mL (n.s.). Differences in IC-values revealed a high sensitivity/specificity of 96.7%/81.8%. IC and VPCT-parameters showed strong, positive correlations. Mean volume CT dose index for VPCT was 63.4 mGy and 4.9 mGy for iodine maps., Conclusion: Thus, IC is a meaningful perfusion marker for local therapy response monitoring in HCC that can be acquired with low radiation dose. This information is important for further therapy response applications using dual and single energy CT., (Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
3. Automated "Bone Subtraction" Image Analysis Software Package for Improved and Faster CT Monitoring of Longitudinal Spine Involvement in Patients with Multiple Myeloma.
- Author
-
Horger M, Ditt H, Liao S, Weisel K, Fritz J, Thaiss WM, Kaufmann S, Nikolaou K, and Kloth C
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Image Processing, Computer-Assisted methods, Male, Middle Aged, Neoplasm Staging, Reproducibility of Results, Retrospective Studies, Whole Body Imaging methods, Lumbar Vertebrae diagnostic imaging, Multidetector Computed Tomography methods, Multiple Myeloma diagnosis, Software, Spinal Neoplasms diagnosis, Subtraction Technique, Thoracic Vertebrae diagnostic imaging
- Abstract
Rationale and Objectives: The study aimed to assess the diagnostic benefit of a novel computed tomography (CT) post-processing software generating subtraction maps of longitudinal non-enhanced CT examinations for monitoring the course of myeloma bone disease in the spine., Materials and Methods: The local institutional review board approved the retrospective data evaluation. Included were 82 consecutive myeloma patients (46 male; mean age, 65.08 ± 9.76) who underwent 188 repeated whole-body reduced-dose Multislice Detector Computed Tomography (MDCT) at our institution between December 2013 and January 2016. Lytic bone lesions were categorized as new or enlarging versus stable. Bone subtraction maps were read in combination with corresponding 1-mm source images comparing results to those of standard image reading of 5-mm axial and 2-mm multiplanar reformat reconstructions (MPR) scans and hematologic markers, and classified as either progressive disease (PD) or stable disease (SD or remission). The standard of reference was 1-mm axial CT image reading + hematologic response both confirmed at follow-up. For statistical purposes, we subgrouped the hematologic response categories similarly to those applied for CT imaging (progression vs stable/response)., Results: According to the standard of reference, 16 patients experienced PD and 66 SD at follow-up. Th sensitivity, specificity, and accuracy for axial 5 mm + 2 mm MPR image versus bone subtraction maps in a "lesion-by-lesion" reading were 97.6%, 92.3%, and 97.2% versus 97.8%, 96.7%, and 97.7%, respectively. The use of bone subtraction maps resulted in a change of response classification in 9.7% of the patients (n = 8) versus 5 mm + 2 mm MPR image reading from SD to PD. Bone sclerosis lesions were detected in 52 out of 82 patients (63.4%). The reading time was significantly lower with the software bone subtraction compared to standard reading (P < 0.01) and 1-mm image reading (P < 0.001)., Conclusion: Accuracy of bone subtraction maps reading for monitoring multiple myeloma is slightly increased over that of conventional axial + MPR image reading and significantly speeds up the reading time., (Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
4. Reproducibility of VPCT parameters in the normal pancreas: comparison of two different kinetic calculation models.
- Author
-
Kaufmann S, Schulze M, Horger T, Oelker A, Nikolaou K, and Horger M
- Subjects
- Adult, Aged, Blood Volume physiology, Carcinoma, Hepatocellular therapy, Contrast Media administration & dosage, Female, Follow-Up Studies, Humans, Image Processing, Computer-Assisted statistics & numerical data, Injections, Intravenous, Iohexol administration & dosage, Iohexol analogs & derivatives, Liver Neoplasms therapy, Male, Middle Aged, Pancreas blood supply, Prospective Studies, Regional Blood Flow physiology, Reproducibility of Results, Retrospective Studies, Sensitivity and Specificity, Cone-Beam Computed Tomography statistics & numerical data, Pancreas diagnostic imaging
- Abstract
Rationale and Objectives: To assess the reproducibility of volume computed tomographic perfusion (VPCT) measurements in normal pancreatic tissue using two different kinetic perfusion calculation models at three different time points., Materials and Methods: Institutional ethical board approval was obtained for retrospective analysis of pancreas perfusion data sets generated by our prospective study for liver response monitoring to local therapy in patients experiencing unresectable hepatocellular carcinoma, which was approved by the institutional review board. VPCT of the entire pancreas was performed in 41 patients (mean age, 64.8 years) using 26 consecutive volume measurements and intravenous injection of 50 mL of iodinated contrast at a flow rate of 5 mL/s. Blood volume(BV) and blood flow (BF) were calculated using two mathematical methods: maximum slope + Patlak analysis versus deconvolution method. Pancreas perfusion was calculated using two volume of interests. Median interval between the first and the second VPCT was 2 days and between the second and the third VPCT 82 days. Variability was assessed with within-patient coefficients of variation (CVs) and Bland-Altman analyses. Interobserver agreement for all perfusion parameters was calculated using intraclass correlation coefficients (ICCs)., Results: BF and BV values varied widely by method of analysis as did within-patient CVs for BF and BV at the second versus the first VPCT by 22.4%/50.4% (method 1) and 24.6%/24.0% (method 2) measured in the pancreatic head and 18.4%/62.6% (method 1) and 23.8%/28.1% (method 2) measured in the pancreatic corpus and at the third versus the first VPCT by 21.7%/61.8% (method 1) and 25.7%/34.5% (method 2) measured also in the pancreatic head and 19.1%/66.1% (method 1) and 22.0%/31.8% (method 2) measured in the pancreatic corpus, respectively. Interobserver agreement measured with ICC shows fair-to-good reproducibility., Conclusions: VPCT performed with the presented examinational protocol is reproducible and can be used for monitoring purposes. Best reproducibility was obtained with both methods for BF and with method 2 also for BV data for both follow-up studies., (Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
5. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging.
- Author
-
Kaufmann S, Sauter A, Spira D, Gatidis S, Ketelsen D, Heuschmid M, Claussen CD, and Thomas C
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Radiographic Image Enhancement methods, Reproducibility of Results, Sensitivity and Specificity, Radiography, Abdominal methods, Radiography, Dual-Energy Scanned Projection methods, Tin, Tomography, X-Ray Computed methods, Ultrafiltration methods, User-Computer Interface
- Abstract
Objectives: To measure and compare the objective image quality of true noncontrast (TNC) images with virtual noncontrast (VNC) images acquired by tin-filter-enhanced, dual-source, dual-energy computed tomography (DECT) of upper abdomen., Materials and Methods: Sixty-three patients received unenhanced abdominal CT and enhanced abdominal DECT (100/140 kV with tin filter) in portal-venous phase. VNC images were calculated from the DECT datasets using commercially available software. The mean attenuation of relevant tissues and image quality were compared between the TNC and VNC images. Image quality was rated objectively by measuring image noise and the sharpness of object edges using custom-designed software. Measurements were compared using Student two-tailed t-test. Correlation coefficients for tissue attenuation measurements between TNC and VNC were calculated and the relative deviations were illustrated using Bland-Altman plots., Results: Mean attenuation differences between TNC and VNC (HUTNC - HUVNC) image sets were as follows: right liver lobe -4.94 Hounsfield units (HU), left liver lobe -3.29 HU, vena cava -2.19 HU, spleen -7.46 HU, pancreas 1.29 HU, fat -11.14 HU, aorta 1.29 HU, bone marrow 36.83 HU (all P < .05); right kidney 0.46 HU, left kidney 0.56 HU, vena portae -0.48 HU and muscle -0.62 HU (nonsignificant). Good correlations between VNC and TNC series were observed for liver, vena portae, kidneys, pancreas, muscle and bone marrow (Pearson's correlation coefficient ≥0.75). Mean image noise was significantly higher in TNC images (P < .0001). Measurements of edge sharpness revealed no significant differences between VNC and TNC images (P = .19)., Conclusion: The Hounsfield units in VNC images closely resemble TNC images in the majority of the organs of the upper abdomen (kidneys, liver, pancreas). In spleen and fat, Hounsfield numbers in VNC images are tend to be higher than in TNC images. VNC images show a low image noise and satisfactory edge sharpness. Other criteria of image quality and the depiction of certain lesions need to be evaluated additionally., (Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.)
- Published
- 2013
- Full Text
- View/download PDF
6. Can whole-body low-dose multidetector CT exclude the presence of myeloma bone disease in patients with monoclonal gammopathy of undetermined significance (MGUS)?
- Author
-
Spira D, Weisel K, Brodoefel H, Schulze M, Kaufmann S, and Horger M
- Subjects
- Adult, Aged, Aged, 80 and over, Diagnosis, Differential, Humans, Middle Aged, Radiation Dosage, Reproducibility of Results, Sensitivity and Specificity, Bone Neoplasms diagnostic imaging, Monoclonal Gammopathy of Undetermined Significance diagnostic imaging, Multiple Myeloma diagnostic imaging, Tomography, X-Ray Computed methods, Whole Body Imaging methods
- Abstract
Rationale and Objectives: To determine the benefit of using whole-body low-dose computed tomography (WBLD-CT) in patients with monoclonal gammopathy of undetermined significance (MGUS) for exclusion of multiple myeloma (MM) bone disease., Materials and Methods: Seventy-one consecutive patients with confirmed MGUS (as defined by the latest criteria of the International Myeloma Working Group) who underwent WBLD-CT for diagnosis were identified retrospectively by a search of our institution's electronic medical record database (2002-2009). Patients were classified as low-risk or intermediate/high-risk and followed over a ≥2-year period with additional CT imaging and/or laboratory parameters. Presence of osteolysis, medullary, or extramedullary abnormalities compatible with involvement by MM was recorded. A diffuse or focal increase in medullary density to Hounsfield unit (HU) values >20 HU/>0 HU was considered suspicious for bone marrow infiltration if no other causes identifiable., Results: The presence of osteolysis was excluded in all 71 patients with MGUS at initial diagnosis and patients were surveilled for ≥2 years. Lytic changes were observed at follow-up in 1/71 patients that progressed to MM and were detectable via WBLD-CT at an early stage (even before a significant rise in M-protein was recorded). In 3/71 patients with MGUS (4%) suspicious bone marrow attenuation values were measured, disclosing disease progression to smoldering myeloma in another patient and false-positive results in 2/71 patients. Bone marrow attenuation assessment resulted in a specificity and negative predictive value of 97%, respectively. No significant difference with respect to bone marrow attenuation was observed in patients with low-risk MGUS versus intermediate- to high-risk MGUS. One of 71 patients showed serologic disease progression to active MM without bone abnormalities detectable., Conclusion: WBLD-CT reliably excludes findings compatible with myeloma in MGUS and thereby complements hematologic laboratory analysis., (Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.)
- Published
- 2012
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.