1. Routine ERG recording using medium frequency flicker stimulus.
- Author
-
Nordenfelt L and Ohman R
- Subjects
- Adult, Aged, Child, Female, Flicker Fusion, Humans, Macular Degeneration diagnosis, Macular Degeneration physiopathology, Male, Middle Aged, Retinal Degeneration diagnosis, Retinal Degeneration physiopathology, Retinal Diseases physiopathology, Electroretinography methods, Retinal Diseases diagnosis
- Abstract
A medium frequency flicker stimulus of 10 Hz is evaluated in routine clinical ERG recording in detecting cone disorders. Tested on a number of normal eyes and on eyes with confirmed or suspected retinal disease it appears to be very useful as a complement to the standard program with the Krakau-Ohman apparatus. It yields an easily recordable and quantified response.
- Published
- 1983
- Full Text
- View/download PDF