1. Transection of Radioactive Seeds in Breast Specimens.
- Author
-
Gilcrease MZ, Dogan BE, Black DM, Contreras A, Dryden MJ, and Jimenez SM
- Subjects
- Adult, Breast pathology, Breast surgery, Breast Neoplasms pathology, Breast Neoplasms surgery, Female, Humans, Middle Aged, Pathology, Surgical, Breast diagnostic imaging, Breast Neoplasms diagnostic imaging, Fiducial Markers adverse effects, Iodine Radioisotopes adverse effects, Occupational Exposure prevention & control, Radiation Exposure prevention & control, Radiopharmaceuticals adverse effects
- Abstract
Radioactive seed localization is a new procedure for localizing breast lesions that has several advantages over the standard wire-localization procedure. It is reported to be safe for both patients and medical personnel. Although it is theoretically possible to transect the titanium-encapsulated seed while processing the breast specimen in the pathology laboratory, the likelihood of such an event is thought to be exceedingly low. In fact, there are no previous reports of such an event in the literature to date. We recently encountered 2 cases in which a radioactive seed was inadvertently transected while slicing a breast specimen at the grossing bench. In this report, we describe each case and offer recommendations for minimizing radioactive exposure to personnel and for preventing radioactive contamination of laboratory equipment.
- Published
- 2016
- Full Text
- View/download PDF