1. Rapid and highly sensitive colorimetric LAMP assay and integrated device for visual detection of monkeypox virus.
- Author
-
Peng, Yadan, Hu, Ruolan, Xue, Shuang, He, Yugan, Tian, Lili, Pang, Zehan, He, Yile, Dong, Yuqi, Shi, Yinghan, Wang, Shuqi, Hong, Bixia, Liu, Ke, Wang, Ruixue, Song, Lihua, Fan, Huahao, Li, Mengzhe, and Tong, Yigang
- Subjects
- *
MONKEYPOX , *NUCLEIC acid isolation methods , *DNA viruses , *FLUORESCENT lamps , *RESOURCE-limited settings , *NUCLEIC acids - Abstract
The monkeypox virus (MPXV) is a linear double-stranded DNA virus with a large genome that causes tens of thousands of infections and hundreds of deaths in at least 40 countries and regions worldwide. Therefore, timely and accurate diagnostic testing could be an important measure to prevent the ongoing spread of MPXV and widespread epidemics. Here, we designed multiple sets of primers for the target region of MPXV for loop-mediated isothermal amplification (LAMP) detection and identified the optimal primer set. Then, the specificity in fluorescent LAMP detection was verified using the plasmids containing the target gene, pseudovirus and other DNA/RNA viruses. We also evaluated the sensitivity of the colorimetric LAMP detection system using the plasmid and pseudovirus samples, respectively. Besides, we used monkeypox pseudovirus to simulate real samples for detection. Subsequent to the establishment and introduction of a magnetic beads (MBs)-based nucleic acid extraction technique, an integrated device was developed, characterized by rapidity, high sensitivity, and remarkable specificity. This portable system demonstrated a visual detection limit of 137 copies/mL, achieving sample-to-answer detection within 1 h. The device has the advantages of integration, simplicity, miniaturization, and visualization, which help promote the realization of accurate, rapid, portable, and low-cost testing. Meanwhile, this platform could facilitate efficient, cost-effective and easy-operable point-of-care testing (POCT) in diverse resource-limited settings in addition to the laboratory. Fig. Schematic diagram of the integrated assay device. The integrated sample-to-answer device was fabricated with three modules, including nucleic acid extraction, LAMP reaction, and colorimetric readout. [Display omitted] • An integrated visual nucleic acid self-testing device based on LAMP assay. • Efficient enrichment of nucleic acids using Si-OH magnetic beads without elution. • Visual results can be obtained within 1 h using the sample-to-answer device. • The LOD for monkeypox virus nucleic acid is as low as 137 copies/mL. • The LAMP-based self-testing device is suitable for point-of-care testing. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF