Background: Colonoscopy requires colon cleansing. For this, many polyethylene glycol (PEG)-based preparations still require a high preparation-volume intake. Using an increased osmotic load with ascorbate (Asc), five new low-volume PEG-based bowel preparations (LVPEG) were tested for clinical proof of concept.Methods: This two-part, open-label study examined preparation-volumes of 1-1.25 L and total required fluid volumes of 2-3 L. Part 1, in healthy volunteers, used mean cumulative 24-h stool weight (target > 2750 g) to identify a lead candidate. Part 2 was endoscopist-blinded: patients undergoing screening colonoscopy were randomized before treatment with the selected lead, one of two variants of it, or the control 2 L PEG + Asc. Two primary endpoints were used for proof of concept demonstration: mean 24-h stool weight and bowel cleansing success (Harefield Cleansing Scale).Results: A total of 120 subjects (30 per group) were enrolled/randomized 1:1:1:1 (max 40:60 gender ratio) per completed Part. In Part 1, LVPEG-3 achieved the largest mean stool weight (3399 g: P < 0.0001 vs target) and was selected for Part 2. In Part 2, stool weights exceeded the target, notably for LVPEG-4 (3215 g: P < 0.001), which achieved 100% cleansing success after a total required fluid intake of 2 L. The control achieved 90% cleansing success. Adverse events were few, gastrointestinal in nature and similar between groups.Conclusions: LVPEG-4 achieved a clinically useful combination of cleansing, safety/tolerability and low consumption volume: 1 L preparation + 1 L required additional fluid. Named NER1006, LVPEG-4 demonstrated clinical proof of concept and warrants further investigation.Trial Registration: October 2012. Identifier: NCT01714466 . EudraCT: 2012-003052-37 The trial was prospectively registered. [ABSTRACT FROM AUTHOR]