1. Novel high-resolution contrast agent ultrasound techniques HiFR CEUS and SR CEUS in combination with shear wave elastography, fat assessment and viscosity of liver parenchymal changes and tumors.
- Author
-
Jung, Ernst Michael, Kaiser, Ulrich, Herr, Wolfgang, Stroszczynski, Christian, and Jung, Friedrich
- Subjects
- *
CONTRAST-enhanced ultrasound , *SHEAR waves , *MEASUREMENT of viscosity , *ELASTOGRAPHY , *VISCOSITY , *CHOLANGITIS - Abstract
BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18–84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF