1. Twenty-Four-Hour Pulsatile Hemodynamics Predict Brachial Blood Pressure Response to Renal Denervation in the SPYRAL HTN-OFF MED Trial.
- Author
-
Weber T, Wassertheurer S, Mayer CC, Hametner B, Danninger K, Townsend RR, Mahfoud F, Kario K, Fahy M, DeBruin V, Peterson N, Negoita M, Weber MA, Kandzari DE, Schmieder RE, Tsioufis KP, Binder RK, and Böhm M
- Subjects
- Blood Pressure physiology, Denervation methods, Hemodynamics physiology, Humans, Kidney, Sympathectomy methods, Treatment Outcome, Hypertension diagnosis, Hypertension surgery, Pulse Wave Analysis
- Abstract
Background: Renal denervation (RDN) lowers blood pressure (BP), but BP response is variable in individual patients. We investigated whether measures of pulsatile hemodynamics, obtained during 24-hour ambulatory BP monitoring, predict BP drop following RDN., Methods: From the randomized, sham-controlled SPYRAL HTN-OFF MED Pivotal trial, we performed a post hoc analysis of BP waveforms from 111 RDN patients and 111 sham controls, obtained with a brachial cuff-based sphygmomanometer. Waveforms were acquired during ambulatory BP monitoring at diastolic BP level and processed with validated ARCSolver algorithms to derive hemodynamic parameters (augmentation index; augmentation pressure; backward and forward wave amplitude; estimated aortic pulse wave velocity). We investigated the relationship between averaged 24-hour values at baseline and the change in 24-hour BP at 3 months in RDN patients, corrected for observed trends in the sham group., Results: There was a consistent inverse relationship between baseline augmentation index/augmentation pressure/backward wave amplitude/forward wave amplitude/estimated aortic pulse wave velocity and BP response to RDN: the decrease in 24-hour systolic BP/diastolic BP was 7.8/5.9 (augmentation index), 8.0/6.3 (augmentation pressure), 6.7/5.4 (backward wave amplitude), 5.7/4.7 (forward wave amplitude), and 7.8/5.2 (estimated aortic pulse wave velocity) mm Hg greater for patients below versus above the respective median value ( P <0.001 for all comparisons, respectively). Taking augmentation index/augmentation pressure/backward wave amplitude/forward wave amplitude/estimated aortic pulse wave velocity into account, a favorable BP response following RDN, defined as a drop in 24-hour systolic blood pressure of ≥5 mm Hg, could be predicted with an area under the curve of 0.70/0.74/0.70/0.65/0.62 ( P <0.001 for all, respectively)., Conclusions: These results suggest that pulsatile hemodynamics, obtained during 24-hour ambulatory BP monitoring, may predict BP response to RDN.
- Published
- 2022
- Full Text
- View/download PDF