1. Impact of Interventricular membranous septum length on pacemaker need with different Transcatheter aortic valve implantation systems.
- Author
-
Hokken TW, van Wiechen MP, Ooms JF, El Azzouzi I, de Ronde M, Kardys I, Budde R, Daemen J, de Jaegere PP, and Van Mieghem NM
- Subjects
- Aged, 80 and over, Aortic Valve diagnostic imaging, Aortic Valve surgery, Cardiac Pacing, Artificial, Case-Control Studies, Humans, Retrospective Studies, Risk Factors, Treatment Outcome, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Heart Valve Prosthesis, Pacemaker, Artificial, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background The need for new permanent pacemaker implantation (PPI) after Transcatheter Aortic Valve Implantation (TAVI) remains a critical issue. Membranous Septum (MS) length is associated with PPI after TAVI. The aim of this study was to identify different MS thresholds for the contemporary THV-platforms. Methods This retrospective, case-control study enrolled all patients who underwent a successful TAVI procedure with contemporary THV-platforms in the Erasmus University Medical Center between January 2016 and March 2020. The follow-up period for new PPI was 30 days. MS-length was determined by Computed Tomography. Results The study consisted 653 TAVI patients with median age 80.6 years (IQR 74.7-84.8). New PPI occurred in 120 patients (18.4%). Patients with new PPI had a shorter MS-length (2.9 mm (IQR 2.3-4.3) vs. 4.2 mm (IQR 2.9-5.7), p < 0.001). MS-length < 3 mm identified a high-risk phenotype with 30.3% PPI-rate (OR 6.5 [95%CI 2.9-14.9]), MS-length 3-6 mm an intermediate-risk phenotype with 15.4% PPI-rate (OR 2.7 [95%CI 1.2-6.2]) and MS > 6 mm a low-risk phenotype with a 6.3% PPI-rate (reference). For the Lotus valve, there was no significant difference in PPI-rates between the high-risk (45.8%, OR 3.5 [95%CI 0.8-15.1]) and low-risk group (20%). By multivariate analysis MS-length, Agatston-score, use of Lotus valve, and ECG with first-degree AV block, RBBB or bifascular block were independent predictors for new PPI. Conclusion MS-length was an independent predictor for new PPI post-TAVI. Three phenotypes were found based on MS-length. MS < 3 mm was universally associated with a high risk for new PPI (>30%). MS > 6 mm represented a low-risk phenotype with PPI-rate < 10%. PPI-rate varied per THV type in the intermediate phenotype. PPI-rate with Lotus was high regardless of MS-length., Competing Interests: Declaration of Competing Interest None., (Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF