1. Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future transcatheter options
- Author
-
Karthik Seetharam, Joel Johnson, Chad Kliger, Craig Basman, S. Jacob Scheinerman, Luigi Pirelli, Nirav C. Patel, Jonathan M. Hemli, and Derek R. Brinster
- Subjects
Pulmonary and Respiratory Medicine ,medicine.medical_specialty ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,Prosthesis ,Transcatheter Aortic Valve Replacement ,03 medical and health sciences ,0302 clinical medicine ,Valve replacement ,Aortic valve replacement ,Multidetector Computed Tomography ,Multidetector computed tomography ,medicine ,Humans ,In patient ,cardiovascular diseases ,Heart Valve Prosthesis Implantation ,business.industry ,Aortic Valve Stenosis ,medicine.disease ,Stenosis ,Treatment Outcome ,medicine.anatomical_structure ,030228 respiratory system ,Coronary occlusion ,Aortic Valve ,Heart Valve Prosthesis ,cardiovascular system ,Surgery ,Radiology ,Cardiology and Cardiovascular Medicine ,business ,Artery - Abstract
Background Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has become a valuable option in patients with bioprosthetic failure. However, potential issues with ViV TAVR may occur in patients with high-risk anatomy for coronary obstruction and patients with baseline smaller bioprosthetic valves at risk for patient prosthesis mismatch. The purpose of this study was, therefore, to use preoperative electrocardiography-gated, multidetector computed tomography (MDCT) in patients undergoing isolated surgical aortic valve replacement (SAVR) to (1) identify which would be high risk for coronary occlusion with ViV TAVR, and (2) predict intraoperative SAVR sizing. Methods Among 223 patients from our institutions' database that underwent SAVR for aortic insufficiency (AI) or aortic stenosis (AS) between January 2012 and January 2020, 48 patients had MDCT imaging before surgery (AI; n = 31, AS; n = 17). Of all patients, 67% (n = 32) were bicuspid morphology. Results With the use of virtual valve implantation, all patients with AI and bicuspid AS had feasible anatomy for ViV TAVR, while 38% of patients with tricuspid AS were high risk for coronary obstruction. There was a strong correlation between actual valve size implanted and preoperative MDCT measurements using annulus average diameter, area, and/or perimeter. Conclusion Preoperative MDCT in patients undergoing SAVR is a useful tool for lifetime management, particularly in patients with tricuspid AS. Decisions for surgical management may change based on MDCT's ability to predict intraoperative SAVR size and determine which patients may be high-risk candidates for future ViV TAVR due to coronary artery obstruction.
- Published
- 2020