11 results on '"Ullah W"'
Search Results
2. Determinants of left atrial local impedance: Relationships with contact force, atrial fibrosis, and rhythm.
- Author
-
Bates AP, Paisey J, Yue A, Banks P, Roberts PR, and Ullah W
- Subjects
- Humans, Male, Female, Middle Aged, Aged, Time Factors, Electrophysiologic Techniques, Cardiac, Electric Impedance, Predictive Value of Tests, Treatment Outcome, Atrial Remodeling, Fibrosis, Atrial Fibrillation physiopathology, Atrial Fibrillation diagnosis, Heart Rate, Catheter Ablation, Atrial Function, Left, Heart Atria physiopathology, Action Potentials
- Abstract
Introduction: The relationships between baseline tissue local impedance (LI), contact force (CF), atrial fibrosis, and atrial rhythm are uninvestigated in a clinical setting. We compared the relationship of LI and CF between atrial fibrillation (AF) and sinus rhythm (SR) accounting for the effects of atrial fibrosis as assessed by bipolar voltage and LI., Methods: Patients undergoing persistent AF ablation were recruited. LI was recorded referenced to patient blood pool (LIr) and concurrent to changes in CF, with data collected at the same locations in AF and SR., Results: Twenty patients were recruited. 109 locations were sampled obtaining 1903 data points (SR: 966, AF: 937). CF correlated strongly with LI (repeated measures correlation = 0.64). The relationship between CF and LIr was logarithmic. Rhythm and CF had a significant main (both p < .0005) and interaction effect (p = .022) on tissue LI: AF demonstrated higher LIr values than SR for similar CF. Bipolar voltage had no effect on the relationship of CF to LIr in either rhythm. Assessing fibrosis using LIr showed an interaction effect with CF for LIr in SR and AF, (SR: p < .0005, AF: p = .01), with increased fibrosis showing lesser change in LIr per gram of CF., Conclusions: CF and rhythm significantly affect the measured LIr of LA myocardium. Optimal catheter-tissue coupling may be better achieved with higher levels of CF and in AF rather than SR. Atrial fibrosis, as assessed by LIr but not bipolar voltage, affected the CF-LI relationship., (© 2024 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.)
- Published
- 2024
- Full Text
- View/download PDF
3. Targeted cluster ablation of non-CTI-dependent atrial arrhythmias in congenital heart disease using ultrahigh-definition mapping.
- Author
-
Kefala A, Claridge S, Wijayagoonawardana P, Sadagopan S, Ullah W, and Yue A
- Subjects
- Humans, Tachycardia surgery, Treatment Outcome, Atrial Flutter diagnosis, Atrial Flutter etiology, Atrial Flutter surgery, Catheter Ablation adverse effects, Catheter Ablation methods, Heart Defects, Congenital diagnosis, Heart Defects, Congenital diagnostic imaging
- Abstract
Background: Ablation of atrial arrhythmias in patients with congenital heart disease (CHD) has markedly improved with advanced mapping systems. However, recurrence rates remain high. The linear ablation strategy is not uncommonly practiced necessitating prolonged ablation times. We report the outcomes of adopting a strategy of minimal, cluster delivery of radiofrequency (RF) energy at critical substrates identified by ultrahigh-definition mapping for atrial arrhythmias in patients with CHD., Methods: Non-cavotricuspid isthmus (non-CTI) atrial tachycardias were ablated with a targeted ablation cluster technique (TACT) using an ultrahigh-density mapping system combined with multielectrode monitoring and endpoint determination in preference to linear ablation. The arrhythmia substrates, RF times, and acute- and medium-term success rates were studied., Results: Fifty-eight tachycardias were mapped and ablated in 42 procedures: 34 non-CTIs and 24 CTIs. A targeted ablation cluster was performed for non-CTI tachycardias, with a median ablation time of 3.1 min. In 53% of non-CTI tachycardias, arrhythmia termination was achieved with ≤2 RF applications. After a mean follow-up of 23.6 months, 27 (80%) patients were free of recurrent atrial arrhythmias. One of 34 targeted non-CTI tachycardia recurred, with a final success rate of 91%. Linear ablation was performed for CTI flutters with a median ablation time of 6.8 min (vs. non-CTIs, p = .006). Three of 21 tachycardias recurred due to reconnection of the ablation line but the final success rate was 100%., Conclusions: The TACT approach for non-CTI atrial arrhythmias in congenital patients as guided by the ultrahigh-density mapping is an effective method with short ablation times and excellent medium-term outcomes., (© 2022 Wiley Periodicals LLC.)
- Published
- 2022
- Full Text
- View/download PDF
4. UK multicenter retrospective comparison of novel active versus conventional passive fixation coronary sinus leads.
- Author
-
Gerontitis D, Diab I, Chow AWC, Hunter RJ, Leyva F, Turley AJ, Williams I, and Ullah W
- Subjects
- Electrodes, Implanted, Humans, Retrospective Studies, United Kingdom, Coronary Sinus diagnostic imaging, Coronary Sinus surgery, Pacemaker, Artificial
- Abstract
Background: A novel active fixation coronary sinus (CS) lead, Attain Stability (AS), has been released aiming to improve targeted lead positioning. Rather than being wedged into the distal vessel, it relies on a side helix for fixation. We aimed to compare implant procedure parameters and electromechanical stability of the AS lead with passive CS leads., Methods: A retrospective study involving six major UK cardiac centers. Patients who received active fixation leads were compared with passive fixation lead recipients in a 1:2 ratio. The primary outcome was total lead displacements (combined macrodisplacement/microdisplacement, defined as displacements requiring repositioning procedures, an increase in threshold ≥0.5 V or pulse width ≥0.5 ms, or a change in pacing polarity)., Results: A total of 761 patients were included (253 AS leads and 508 passive fixation leads), of which 736 had follow-up data. The primary endpoint rate was 31% (75/241) in the active and 43% (214/495) in the passive group (p = .002). Six patients (2.5%) in the active group and 14 patients (2.8%) in the passive group required CS lead repositioning procedures (p = 0.981). On multivariable analysis, active leads were associated with a reduction in lead displacements, odds ratio 0.66 (95% confidence interval: 0.46-0.95), p = .024. There were differences in favor of passive leads in procedure duration, 120 (96-149) versus 127 (105-155) min (p = .008), and fluoroscopy time, 17 (11-26) versus 18.5 (13-27) min (p = .0022). The median follow-up duration was similar (active vs. passive): 31 (17-47) versus 34 (16-71) weeks, (p = .052)., Conclusion: AS CS leads had improved electromechanical stability compared with passive fixation leads, with only minimal increases in implant procedure and fluoroscopy times., (© 2020 Wiley Periodicals LLC.)
- Published
- 2020
- Full Text
- View/download PDF
5. STAR mapping method to identify driving sites in persistent atrial fibrillation: Application through sequential mapping.
- Author
-
Honarbakhsh S, Schilling RJ, Finlay M, Keating E, Ullah W, and Hunter RJ
- Subjects
- Aged, Atrial Fibrillation physiopathology, Atrial Fibrillation surgery, Catheter Ablation, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Pulmonary Veins surgery, Recurrence, Reproducibility of Results, Stochastic Processes, Time Factors, Treatment Outcome, Action Potentials, Atrial Fibrillation diagnosis, Electrophysiologic Techniques, Cardiac, Heart Rate, Pulmonary Veins physiopathology, Signal Processing, Computer-Assisted
- Abstract
Introduction: The optimal way to map localized drivers in persistent atrial fibrillation (AF) remains unclear. The objective of the study was to apply a novel vector mapping approach called Stochastic Trajectory Analysis of Ranked signals (STAR) in AF., Methods and Results: Patients having persistent AF ablation were included. Early sites of activation (ESA) identified on global STAR maps created with basket catheters were used to guide AF ablation post-pulmonary vein isolation (PVI). All patients also had sequential STAR maps created with ≥10 PentaRay recordings of 30 seconds. These were validated offline in their ability to identify the ESA targeted with a study-defined ablation response (AF termination or cycle length [CL] slowing of ≥30 ms). Thirty-two patients were included in whom 92 ESA were identified on the global STAR maps, with 73 of 83 targeted sites demonstrating an ablation response (24 AF termination and 49 CL slowing). Sixty-one out of 73 (83.6%) ESA were also identified on the sequential STAR maps. These showed greater consistency (P < .001), were seen pre- and post-PVI (P < .001) and were more likely to be associated with AF termination on ablation (P = .007). The sensitivity and specificity of sequential mapping for the detection of ESA with an ablation response was 84.9% (95% confidence interval [CI] = 74.6-92.2) and 90.0% (95% CI = 55.5-99.8), respectively. During a follow-up of 19.4 ± 3.7 months, 28 (80%) patients were free from AF/atrial tachycardia., Conclusions: STAR mapping consistently identified ESA in all patients and the ablation response was compatible with ESA being driver sites. Mechanistically important ESA were successfully identified using sequential recordings., (© 2019 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.)
- Published
- 2019
- Full Text
- View/download PDF
6. Development, in vitro validation and human application of a novel method to identify arrhythmia mechanisms: The stochastic trajectory analysis of ranked signals mapping method.
- Author
-
Honarbakhsh S, Hunter RJ, Finlay M, Ullah W, Keating E, Tinker A, and Schilling RJ
- Subjects
- Animals, Atrial Fibrillation physiopathology, Atrial Fibrillation surgery, Catheter Ablation, Cell Line, Humans, Mice, Myocytes, Cardiac physiology, Predictive Value of Tests, Reproducibility of Results, Stochastic Processes, Tachycardia, Supraventricular physiopathology, Tachycardia, Supraventricular surgery, Time Factors, Treatment Outcome, Action Potentials, Atrial Fibrillation diagnosis, Diagnosis, Computer-Assisted, Electrophysiologic Techniques, Cardiac, Heart Rate, Signal Processing, Computer-Assisted, Tachycardia, Supraventricular diagnosis, Voltage-Sensitive Dye Imaging
- Abstract
Introduction: Stochastic trajectory analysis of ranked signals (STAR) is a novel method for mapping arrhythmia. The aim was to describe its development and validation as a mapping tool., Methods and Results: The method ranks electrodes in terms of the proportion of the time they lead relative to neighboring electrodes and ascribes a predominant direction of activation between electrodes. This was conceived with the aim of mapping atrial fibrillation (AF) drivers. Validation of this approach was performed in stages. First, in vitro simultaneous multi-electrode array and optical mapping were performed on spontaneously fibrillating HL1 cell cultures, to determine if such a method would be able to determine early sites of activation (ESA). A clinical study acquiring unipolar electrograms using a 64-pole basket for the purposes of STAR mapping in patients undergoing atrial tachycardia (AT) ablation. STAR maps were analyzed by physicians to see if arrhythmia mechanisms could be correctly determined. Mapping was then repeated during atrial pacing. STAR mapping of in vitro activation sequences accurately correlated to the optical maps of planar and rotational activation. Thirty-two ATs were mapped in 25 patients. The ESA accurately identified focal/micro-reentrant ATs and the mechanism of macro-reentrant ATs was effectively demonstrated. STAR method accurately identified four pacing sites in all patients., Conclusions: This novel STAR method correlated well with the gold standard of optical mapping in vitro and was able to accurately identify AT mechanisms. Further analysis is needed to determine whether the method might be of use mapping AF., (© 2019 Wiley Periodicals, Inc.)
- Published
- 2019
- Full Text
- View/download PDF
7. The Impact of Known Heart Disease on Long-Term Outcomes of Catheter Ablation in Patients with Atrial Fibrillation and Left Ventricular Systolic Dysfunction: A Multicenter International Study.
- Author
-
Prabhu S, Ling LH, Ullah W, Hunter RJ, Schilling RJ, McLellan AJ, Earley MJ, Sporton SC, Voskoboinik A, Blusztein D, Mariani JA, Lee G, Taylor AJ, Kalman JM, and Kistler PM
- Subjects
- Adult, Aged, Atrial Fibrillation mortality, Cardiomyopathy, Dilated mortality, Catheter Ablation mortality, Female, Follow-Up Studies, Humans, Male, Middle Aged, Retrospective Studies, Time Factors, Treatment Outcome, Ventricular Dysfunction, Left mortality, Atrial Fibrillation surgery, Cardiomyopathy, Dilated surgery, Catheter Ablation trends, Internationality, Ventricular Dysfunction, Left surgery
- Abstract
Background: Catheter ablation for AF is an effective treatment for patients with AF and systolic LV dysfunction; however, the clinical outcome is variable. We evaluated the impact of cardiomyopathy etiology on long-term outcomes post-catheter ablation., Methods: Patients undergoing AF ablation across 3 centers (2 Australian, 1 UK) from 2002 to 2014, with LVEF<45% were evaluated. Patients were stratified into those with known heart disease as a cause of cardiomyopathy (KHD), and those with idiopathic dilated cardiomyopathy (IDCM)., Results: One hundred and one patients (IDCM = 77, KHD = 24) with AF and LVEF <45% underwent AF ablation. The KHD group (ischemic HD in 67%) were older (61 ± 7 vs. 55 ± 11 years, P = 0.005), with a higher CHADS2 score (2.0 ± 0.8 vs. 1.6 ± 0.7, P = 0.016), but otherwise well matched. After mean follow-up of 36 ± 23 months, AF control was greater in the IDCM group (82% vs. 50% in KHD, P < 0.001). On multivariate analysis IDCM was associated with long-term AF control (P = 0.033). The IDCM group had less functional impairment at follow-up (NYHA class 1.5 ± 0.7 vs. 2.0 ± 0.8, P = 0.005) and improved LVEF (50 ± 11% vs. 38 ± 10%, P < 0.001). Super responders (EF improvement >15%) were overwhelmingly in the IDCM group (94% vs. 6%, P < 0.001) with greater AF control (89% vs. 61%, P < 0.001). All-cause mortality was significantly higher in the KHD group (17% vs. 1.3%, P = 0.002)., Conclusion: IDCM was associated with greater AF control, and improvement in symptoms and LVEF compared to patients with KHD post-AF ablation. AF is an important reversible cause of HF in patients with an unexplained CM and catheter ablation an effective treatment option., (© 2015 Wiley Periodicals, Inc.)
- Published
- 2016
- Full Text
- View/download PDF
8. Point-by-Point Radiofrequency Ablation Versus the Cryoballoon or a Novel Combined Approach: A Randomized Trial Comparing 3 Methods of Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation (The Cryo Versus RF Trial).
- Author
-
Hunter RJ, Baker V, Finlay MC, Duncan ER, Lovell MJ, Tayebjee MH, Ullah W, Siddiqui MS, McLEAN A, Richmond L, Kirkby C, Ginks MR, Dhinoja M, Sporton S, Earley MJ, and Schilling RJ
- Subjects
- Aged, Anti-Arrhythmia Agents therapeutic use, Catheter Ablation adverse effects, Combined Modality Therapy, Cryosurgery adverse effects, Disease-Free Survival, Electrocardiography, Ambulatory, Endpoint Determination, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Treatment Outcome, Atrial Fibrillation therapy, Catheter Ablation methods, Cryosurgery methods, Pulmonary Veins
- Abstract
Introduction: Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared these 3 strategies in a randomized controlled trial., Methods and Results: Patients undergoing first time paroxysmal AF ablation were randomized to RFCA, CRYO, or COMBINED. Patients were followed up at 3, 6, and 12 months with 7 days of ambulatory ECG monitoring. Success was defined as freedom from arrhythmia without antiarrhythmic drugs after a single procedure. A total of 237 patients were randomized. Success at 1 year was achieved in 47% in the RFCA group, 67% in the CRYO group, and 76% in the COMBINED group (P < 0.001 for RFCA vs. CRYO, P<0.001 for RFCA vs. COMBINED, and P = 0.220 for CRYO vs. COMBINED). Procedure time was 211 (IQR 174-256) minutes for RFCA compared to 167 (136-202) minutes for CRYO and 278 (243-327) minutes for COMBINED (P < 0.001 for RFCA vs. COMBINED, RFCA vs. CRYO, and CRYO vs. COMBINED groups)., Conclusions: Pulmonary vein isolation for paroxysmal AF is faster with CRYO and results in a higher single procedure success rate than conventional point by point RFCA. The COMBINED approach was not superior to CRYO alone., (© 2015 Wiley Periodicals, Inc.)
- Published
- 2015
- Full Text
- View/download PDF
9. Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients.
- Author
-
Jarman JWE, Panikker S, DAS M, Wynn GJ, Ullah W, Kontogeorgis A, Haldar SK, Patel PJ, Hussain W, Markides V, Gupta D, Schilling RJ, and Wong T
- Subjects
- Aged, Atrial Fibrillation diagnosis, Atrial Fibrillation physiopathology, Catheter Ablation adverse effects, Chi-Square Distribution, Disease-Free Survival, England, Female, Fluoroscopy, Humans, Logistic Models, Male, Middle Aged, Multivariate Analysis, Pulmonary Veins physiopathology, Radiation Dosage, Radiography, Interventional methods, Recurrence, Retrospective Studies, Risk Factors, Time Factors, Treatment Outcome, Atrial Fibrillation surgery, Catheter Ablation methods, Pulmonary Veins surgery
- Abstract
Introduction: Contact force sensing (CFS) technology improves acute pulmonary vein isolation durability; however, its impact on the clinical outcome of ablating atrial fibrillation (AF) is unknown., Methods and Results: First time AF ablation procedures employing CFS from 4 centers were matched retrospectively to those without CFS in a 1:2 manner by type of AF. Freedom from atrial tachyarrhythmia was defined as the primary outcome measure, and fluoroscopy time the secondary outcome measure. Nineteen possible explanatory variables were tested in addition to CFS. A total of 600 AF ablation procedures (200 using CFS and 400 using non-CFS catheters) performed between 2010 and 2012 (46% paroxysmal, 36% persistent, 18% long-lasting persistent) were analyzed. The mean follow-up duration was 11.4 ± 4.7 months-paroxysmal AF 11.2 ± 4.1 CFS versus 11.3 ± 3.9 non-CFS (P = 0.745)-nonparoxysmal AF 10.4 ± 4.5 CFS versus 11.9 ± 5.4 non-CFS (P = 0.015). The use of a CFS catheter independently predicted clinical success in ablating paroxysmal AF (HR 2.24 [95% CIs 1.29-3.90]; P = 0.004), but not nonparoxysmal AF (HR 0.73 [0.41-1.30]; P = 0.289) in a multivariate analysis that included follow-up duration. Among all cases, the use of CFS catheters was associated with reduced fluoroscopy time in multivariate analysis (reduction by 7.7 [5.0-10.5] minutes; P < 0.001). Complication rates were similar in both groups., Conclusions: At medium-term follow-up, CFS catheter technology is associated with significantly improved outcome of first time catheter ablation of paroxysmal AF, but not nonparoxysmal AF. Fluoroscopy time was lower when CFS technology was employed in all types of AF ablation procedures., (© 2014 Wiley Periodicals, Inc.)
- Published
- 2015
- Full Text
- View/download PDF
10. Impact of steerable sheaths on contact forces and reconnection sites in ablation for persistent atrial fibrillation.
- Author
-
Ullah W, Hunter RJ, McLean A, Dhinoja M, Earley MJ, Sporton S, and Schilling RJ
- Subjects
- Aged, Atrial Fibrillation diagnosis, Female, Humans, Male, Middle Aged, Retrospective Studies, Treatment Outcome, Atrial Fibrillation surgery, Catheter Ablation instrumentation, Catheter Ablation methods, Central Venous Catheters
- Abstract
Background: In preclinical studies, catheter contact force (CF) during radiofrequency ablation correlates with the subsequent lesion size. We investigated the impact of steerable sheaths on ablation CF, its consistency, and wide area circumferential ablation (WACA) line reconnection sites., Methods and Results: Five thousand and sixty-four ablations were analyzed across 60 patients undergoing first-time ablation for persistent AF using a CF-sensing catheter: 19 manual nonsteerable sheath (Manual-NSS), 11 manual steerable sheath, and 30 robotic steerable sheath (Sensei, Hansen Medical Inc.) procedures were studied. Ablation CFs were higher in the steerable sheath groups for all left atrial ablations and also WACA ablations specifically (P < 0.006), but less consistent per WACA segment (P < 0.005). There were significant differences in the CFs around both WACAs by group: in the left WACA CFs were lower with Manual-NSS, other than at the anterior-inferior and posterior-superior regions, and lower in the right WACA, other than the anterior-superior region. There was a difference in the proportion of segments chronically reconnecting across groups: Manual-NSS 26.5%, manual steerable sheath 4.6%, robotic 12% (P < 0.0005). The left atrial appendage/PV ridge and right posterior wall were common sites of reconnection in all groups., Conclusions: Steerable sheaths increased ablation CF; however, there were region-specific heterogeneities in the extent of increment, with some segments where they failed to increase CF. Steerable sheath use was associated with reduced WACA-segment reconnection. It may be that the benefits of steerable sheath use in terms of higher CFs could be translated to improved clinical outcomes if regional weaknesses of this technology are taken into account during ablation procedures., (© 2014 Wiley Periodicals, Inc.)
- Published
- 2015
- Full Text
- View/download PDF
11. Factors affecting catheter contact in the human left atrium and their impact on ablation efficacy.
- Author
-
Ullah W, Hunter RJ, Baker V, Dhinoja MB, Sporton S, Earley MJ, and Schilling RJ
- Subjects
- Aged, Atrial Fibrillation diagnosis, Atrial Fibrillation physiopathology, Catheter Ablation adverse effects, Electric Impedance, Equipment Design, Female, Heart Atria physiopathology, Humans, Linear Models, Male, Middle Aged, Multivariate Analysis, Robotic Surgical Procedures adverse effects, Time Factors, Transducers, Pressure, Treatment Outcome, Atrial Fibrillation surgery, Cardiac Catheters, Catheter Ablation instrumentation, Heart Atria surgery, Robotic Surgical Procedures instrumentation
- Abstract
Introduction: Preclinical work suggests factors including catheter orientation and contact consistency during individual radiofrequency ablations influence lesion size. Our aim was to investigate factors affecting catheter contact in the left atrium (LA) and their effects on ablation., Methods and Results: A total of 2,298 8-second static LA mapping points were studied in 30 patients undergoing ablation for AF (16 in AF, 14 sinus rhythm [SR], 18 remote robotic navigation [RRN] procedures) using a contact force (CF) sensing catheter. CF variability (CFV: difference between 20 Hz-sampled CF waveform mean peak and trough) increased with mean CF, Spearman's ρ = 0.6, P < 0.005. Catheter drift correlated weakly with CF (Pearson's correlation -0.06, P = 0.005). CFV was higher in SR than AF and with RRN (P < 0.001). In AF, there was less catheter drift for RRN than manual navigation points but the converse was true in SR. In 747 static 30 second LA ablations, the influence of contact parameters on ablation efficacy was compared by multivariate analysis of impedance drop during ablation: a lesser drop suggesting reduced efficacy. For a given force time integral (FTI), increased CFV (>5 g) and locational drift (>3.5 mm), perpendicular contact, SR and RRN usage were associated with a lesser impedance drop with ablation (P < 0.005 for each), suggesting reduced efficacy., Conclusions: Beyond the FTI, the quality of catheter contact influences ablation efficacy, and clinical catheter contact is affected by multiple factors, including the atrial rhythm and catheter navigation mode. Maximal efficacy is provided by parallel contact with CFV ≤5 g, catheter drift ≤3.5 mm, and manual navigation., (© 2014 Wiley Periodicals, Inc.)
- Published
- 2015
- Full Text
- View/download PDF