1. Simultaneous determination of the camptothecin analogue CPT-11 and its active metabolite SN-38 by high-performance liquid chromatography: application to plasma pharmacokinetic studies in cancer patients
- Author
-
D. Gandia, Guy G. Chabot, Anne Mathieu-Boué, Iman Barilero, Micheline Re, Jean-Pierre Armand, and Alain Gouyette
- Subjects
Volume of distribution ,Chromatography ,Time Factors ,SN-38 ,General Chemistry ,Irinotecan ,High-performance liquid chromatography ,Antineoplastic Agents, Phytogenic ,chemistry.chemical_compound ,chemistry ,Pharmacokinetics ,Blood plasma ,medicine ,Humans ,Camptothecin ,Steady state (chemistry) ,Infusions, Intravenous ,Active metabolite ,Chromatography, High Pressure Liquid ,medicine.drug - Abstract
CPT-11 (I; 7-ethyl-10-[4-(1-piperidino)-1- piperidino]carbonyloxycamptothecin) is a new anticancer agent currently under clinical development. A sensitive high-performance liquid chromatographic assay suitable for the simultaneous determination of I and its active metabolite SN-38 (II) in human plasma, and their preliminary clinical pharmacokinetics, are described. Plasma samples were processed using a solid-phase (C18) extraction step allowing mean recoveries of I, II and the internal standard camptothecin (III) of 84, 99 and 72%, respectively. The extracts were chromatographed on a C18 reversed-phase column with a mobile phase composed of acetonitrile, phosphate buffer and heptanesulphonic acid, with fluorescence detection. The calibration graphs were linear over a wide range of concentrations (1 ng/ml-10 micrograms/ml), and the lower limit of determination was 1 ng/ml for both I and II. The method showed good precision: the within-day relative standard deviation (R.S.D.) (5-1000 ng/ml) was 13.0% (range 4.9-19.4%) for I and 12.8% (6.7-19.1%) for II; the between-day R.S.D. (5-10,000 ng/ml was 7.9% (5.4-17.5%) for I and 9.7% (3.5-15.1%) for II. Using this assay, plasma pharmacokinetics of both I and II were simultaneously determined in three patients receiving 100 mg/m2 I as a 30-min intravenous infusion. The mean peak plasma concentration of I at the end of the intravenous infusion was 2400 +/- 285 ng/ml (mean +/- standard error of the mean). Plasma decay was triphasic with half-lives alpha, beta and gamma of 5.4 +/- 1.8 min, 2.5 +/- 0.5 h and 20.2 +/- 4.6 h, respectively. The volume of distribution at steady state was 105 +/- 15 l/m2, and the total body clearance was 12.5 +/- 1.9 l/h.m2. The maximum concentrations of the active metabolite II reached 36 +/- 11 ng/ml.
- Published
- 1992