1. Accuracy of Computer-Aided Design/Computer-Aided Manufacturing-Assisted Mandibular Reconstruction With a Fibula Free Flap.
- Author
-
Geusens J, Sun Y, Luebbers HT, Bila M, Darche V, and Politis C
- Subjects
- Aged, Computer-Aided Design, Female, Humans, Male, Mandible surgery, Middle Aged, Plastic Surgery Procedures, Surgery, Computer-Assisted methods, Tomography, X-Ray Computed, Fibula surgery, Free Tissue Flaps, Mandibular Reconstruction
- Abstract
Background: The recent increase in computer-aided design and computer-aided manufacturing (CAD/CAM)-assisted surgery has warranted a thorough evaluation of the accuracy of virtual plan execution. Mandibular reconstructions with a fibula free flap were evaluated by comparing the fibular segments postoperatively with the virtual surgical plans., Methods: This study included computed tomography data for 20 patients (11 males; mean age 61.3 years, range 47-74) that received a mandibular reconstruction with a fibula free flap. Linear distances (superior and inferior borders) of 41 fibula segments and intercoronoid distances were measured., Results: The mean difference was 3.11 ± 2.80 mm for superior borders (range 0.02-12.20 mm), and 2.75 ± 2.61 mm for inferior borders (range 0.22-13.58 mm). The mean intercoronoid difference was 3.57 ± 1.80 mm (range 0.91-6.11 mm)., Conclusion: This study confirmed the presumed accuracy regarding the use of fibular and mandibular cutting guides. CAD/CAM is an attractive technique which enhances efficiency and assurance during surgery and preoperative planning.
- Published
- 2019
- Full Text