1. Release test of alliin/alliinase double-layer tablet by HPLC—Allicin determination.
- Author
-
Liang, Yan, Zhang, Jing-Jing, Zhang, Qi-Bing, Wang, Zhong-Xia, Yin, Zong-Ning, Li, Xin-Xia, Chen, Jian, and Ye, Li-Ming
- Subjects
ALLIIN ,DRUG tablets ,HIGH performance liquid chromatography ,PHARMACOPOEIAS ,CARBOXYLIC acids ,HOMOGENEITY - Abstract
Abstract: A simple, precise and accurate method was developed and validated for the determination of allicin release from alliin/alliinase double-layer tablets. According to Appendix XC II of Chinese Pharmacopoeia 2010 edition Volume II, a small glass-method was adopted at the rotational speed of 100r/min using 100mL phosphate buffer (pH 6.8) as release medium. The release amount was determined by HPLC with a C
18 column (250mm×4.6mm, 5μm) using the mobile phase consisting of methanol −0.4% carboxylic acid (65:35) at a flow rate of 1mL/min and UV detection at 242nm. The current method demonstrates good linearity over the range 4.052–405.2μg/mL (r2 =0.9999) with an average recovery of 105.5%(RSD=1.25%). The accumulative release of alliin/alliinase double-layer tablets had good homogeneity for within- and between-batches. The method established is simple, accurate and repeatable for the determination of allicin release from alliin/alliinase double-layer tablets. [Copyright &y& Elsevier]- Published
- 2013
- Full Text
- View/download PDF