1. Computer modeling of occlusal surfaces of posterior teeth with the CICERO CAD/CAM system.
- Author
-
Olthoff LW, Van Der Zel JM, De Ruiter WJ, Vlaar ST, and Bosman F
- Subjects
- Dental Occlusion, Traumatic prevention & control, Humans, Mandible, Models, Dental, Molar, Computer-Aided Design, Crowns, Dental Articulators, Dental Prosthesis Design, Jaw Relation Record methods
- Abstract
Statement of Problem: Static and dynamic occlusal interference frequently needs to be corrected by selective grinding of the occlusal surface of conventional cast and ceramic-fused-to-metal restorations. CAD/CAM techniques allow control of the dimensional contours of these restorations. However, parameters responsible for the occlusal form need to be determined. In most articulators, these parameters are set as default values. Which technique is best for minimizing the introduction of occlusal interference in restorations has not been determined., Purpose: This study investigated differences in crown structure of a crown designed in static occlusion (STA) with designs adapted for dynamic occlusal interferences. Therefore, values from an optoelectronic registration system (String-Condylocomp, KAVO), an occlusal generated path (OGP) technique and default settings (DEF) were used in the CICERO CAD/CAM system., Material and Methods: Morphology of CON, DEF, and OGP crowns was compared with that of the STA crown with respect to differences in a buccolingual section and frequency of occlusal distances in an interocclusal range of 1 mm, measured from the occlusal surface of the crown., Results: All crown types fulfilled the esthetic and morphologic criteria for restorations in clinical dentistry. Difference in the morphology of the OGP crown, compared with that of the STA crown, was greater than that for the CON and DEF crowns. These differences were seen especially in the distobuccal part of the occlusal surface; however, the number of occlusal contacts was considered sufficient to stabilize occlusion., Conclusion: Functional occlusion, adapted to dynamic occlusion in a CICERO crown for the first mandibular molar, can be obtained using data acquired with the String-Condylocomp registration system. The OGP technique was preferred to other techniques because of the simplicity of the technique for eliminating potential problems with opposing teeth during motion. However, this is achieved at the cost of fewer points of contact during occlusion than with the CON crown.
- Published
- 2000
- Full Text
- View/download PDF