1. Response of the Li-7-enriched Cs2LiYCl6:Ce (CLYC-7) scintillator to 6–60 MeV neutrons.
- Author
-
Woolf, Richard S., Hutcheson, Anthony L., Phlips, Bernard F., and Wulf, Eric A.
- Subjects
- *
NEUTRONS , *METHYL groups , *SCINTILLATORS , *FAST neutrons , *MATHEMATICAL equivalence - Abstract
We discuss a test campaign designed to irradiate the 7 Li-enriched Cs 2 LiYCl 6 :Ce 3+ (CLYC-7) scintillator with 6–60 MeV neutrons using the cyclotron located at the Crocker Nuclear Laboratory in Davis, CA. CLYC-7 is a newly developed scintillator that exhibits the ability to make good γ-ray measurements and has the ability to detect and discriminate fast neutrons via pulse shape discrimination (PSD) while functioning as a spectrometer. This allows a single detector to make good measurement of both stimuli simultaneously. The response of this scintillation detector has been investigated below 20 MeV [1] but has yet to be explored for energies greater than 20 MeV. Understanding the spectral and pulse shape response across a broad energy range is important for any radiation detection instrumentation capable of detecting multiple species. At the highest energies sampled, the CLYC-7 PSD demonstrated not only the standard electron/proton separation expected in a mixed γ/ n field but the ability to discriminate locally produced deuterons, tritons and α particles. We show the results from the four different neutron beam energies sampled during the experiment. Lastly, we present the results obtained for relating the light output equivalence between electrons and protons/deuterons. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF