1. Air isodose curves in a mammography room
- Author
-
Rochele Lykawka, Gabriela Hoff, Elaine Evaní Streck, and Maria Cecília Baptista Todeschini Adad
- Subjects
Radioprotection ,Dosimeter ,medicine.diagnostic_test ,business.industry ,Curvas de isodose ,Radioproteção ,Mamografia ,EXAMINATION ROOM ,Imaging phantom ,Radiological weapon ,Absorbed dose ,Scattering radiation ,Isodose curves ,Medicine ,Mammography ,Radiology, Nuclear Medicine and imaging ,Radiation protection ,business ,Nuclear medicine - Abstract
OBJETIVO: O objetivo deste trabalho foi obter a distribuição da dose absorvida no ar numa sala de mamografia durante a simulação de um exame mamográfico, visando a reavaliar a necessidade do uso de barreiras de proteção radiológica nessas salas e a exposição das pacientes. MATERIAIS E MÉTODOS: Os dados da dose absorvida no ar foram coletados mediante simulação de exame mamográfico de um simulador de mama de BR12, em um equipamento Senograph 600T-Senix HF. Para tal, 158 pastilhas de CaSO4 foram distribuídas em malhas retangulares em torno do bucky, em três alturas distintas. RESULTADOS: O valor mais elevado da dose absorvida no ar, registrado no ponto central da superfície do simulador, centralizado no feixe primário, foi de 8,33 mGy, enquanto o menor valor registrado, devido exclusivamente ao espalhamento, foi de 0,008 mGy. CONCLUSÃO: Estes resultados indicam que o uso de blindagem adicional nas salas de mamografia pode não ser necessário na incidência crânio-caudal, desde que as distâncias consideradas neste trabalho sejam observadas. No entanto, eles enfatizam a necessidade de proteção da paciente. OBJECTIVE: The present study was aimed at evaluating the absorbed dose in air in a medical examination room during a mammography simulation, to re-evaluate the level of patients' exposure as well as the necessity of radiological protection barriers. MATERIALS AND METHODS: Data regarding absorbed dose in air were collected during mammography simulation with a BR12 breast phantom in a Senograph 600T-Senix HF mammograph. For this purpose, 158 CaSO4 dosimeters were distributed over rectangular grids around the bucky at three different heights. RESULTS: The highest value for absorbed dose in air recorded on the center of the phantom surface and centralized on the primary beam was 8.33 mGy, while the lowest value recorded exclusively due to radiation scattering was 0.008 mGy. CONCLUSION: These results indicate that the utilization of additional shielding in mammography facilities might not be necessary for craniocaudal acquisition, provided the distances considered for the present study are observed. However, the necessity of radiation protection of the patient should be emphasized.
- Published
- 2008
- Full Text
- View/download PDF