1. Vertebral Compression Fractures: Third-Generation Dual-Energy CT for Detection of Bone Marrow Edema at Visual and Quantitative Analyses
- Author
-
Anke Heidemeier, Bernhard Petritsch, Bernhard Krauss, Andreas Max Weng, Tobias Gassenmaier, Richard K. Wagner, Timo M. Heintel, Aleksander Kosmala, and Thorsten A. Bley
- Subjects
Adult ,Male ,medicine.medical_specialty ,Adolescent ,Radiographic image interpretation ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Bone Marrow ,Fractures, Compression ,medicine ,Edema ,Humans ,Radiology, Nuclear Medicine and imaging ,In patient ,Prospective Studies ,Aged ,Aged, 80 and over ,business.industry ,Middle Aged ,Bone marrow edema ,Compression (physics) ,Third generation ,030220 oncology & carcinogenesis ,Radiographic Image Interpretation, Computer-Assisted ,Spinal Fractures ,Female ,Radiology ,Tomography ,Dual energy ct ,Tomography, X-Ray Computed ,business - Abstract
Purpose To assess the diagnostic performance of a third-generation dual-energy computed tomographic (CT) virtual noncalcium (VNCa) technique for detection of traumatic bone marrow edema in patients with vertebral compression fractures. Materials and Methods This prospective study was approved by the institutional review board. Informed consent was obtained from all participants. Twenty-two consecutive patients with 37 morphologic vertebral fractures were studied between October 2015 and May 2016. All patients underwent dual-energy CT (90 kV and 150 kV with a tin filter) and 3-T magnetic resonance (MR) imaging. Two independent readers visually evaluated all vertebral bodies (n = 163) for the presence of abnormal bone marrow attenuation on VNCa images by using color-coded maps and performed a quantitative analysis of CT numbers on VNCa images. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic analysis to calculate cutoff values. Results In the visual analysis, VNCa images had an overall sensitivity of 64.0%, specificity of 99.3%, accuracy of 93.9%, positive predictive value of 94.1%, and negative predictive value of 93.8%. The interobserver agreement was excellent (κ = 0.85). CT numbers obtained from VNCa images were significantly different in vertebral bodies with and without edema (P.001). Receiver operating characteristic analysis revealed an area under the curve of 0.922. A cutoff value of -47 provided sensitivity of 92.0%, specificity of 82.6%, accuracy of 84.0%, positive predictive value of 48.9%, and negative predictive value of 98.3% for the differentiation of edematous vertebral bodies. Conclusion Visual and quantitative analyses of dual-energy VNCa images showed excellent diagnostic performance for assessing traumatic bone marrow edema in vertebral compression fractures.
- Published
- 2017
- Full Text
- View/download PDF