1. Intermediate-Term Outcomes After Aortic Valve Replacement With the Medtronic 3F Stentless Prosthesis
- Author
-
Alessandro Bellisario, Fabrizio Pirro, Guglielmo Stefanelli, Luca Weltert, and Massimo Longo
- Subjects
Male ,Pulmonary and Respiratory Medicine ,Aortic valve ,medicine.medical_specialty ,medicine.medical_treatment ,Bentall procedure ,030204 cardiovascular system & hematology ,Prosthesis Design ,Prosthesis ,03 medical and health sciences ,0302 clinical medicine ,Aortic valve replacement ,Valve replacement ,medicine ,Humans ,Aged ,Retrospective Studies ,Aged, 80 and over ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,business.industry ,Extracorporeal circulation ,Hemodynamics ,Mean Aortic Pressure ,Middle Aged ,medicine.disease ,Aortic Valve Disease ,Surgery ,Treatment Outcome ,medicine.anatomical_structure ,030228 respiratory system ,Heart Valve Prosthesis ,Female ,Stents ,Implant ,Cardiology and Cardiovascular Medicine ,business ,Follow-Up Studies - Abstract
Background This study evaluated the early and intermediate-term clinical and hemodynamic results after implant of the Medtronic 3F (Minneapolis, MN) stentless aortic valve. Methods Between March 2007 and August 2015, 226 consecutive patients affected by aortic valve disease received a 3F valve at our unit by a single surgeon. The valve in 30 patients was included in a tubular prosthesis for a Bentall procedure. Size ranged between 21 and 29, age at operation was 74.17 ± 8.58 years, mean logistic European System for Cardiac Operative Risk Evaluation was 9.73 ± 6.00, and 51.3% of patients received a concomitant procedure. For isolated valve replacement, mean extracorporeal circulation time was 92 ± 17 minutes, and cross-clamp time was 73 ± 11 minutes. Follow-up was 100% complete and was a mean of 63 ± 2.4 months (range, 6-138 months). Primary end points were early and late mortality, freedom from endocarditis, freedom from structural valve deterioration, and freedom from valve-related reoperation. Results Early mortality after isolated aortic valve replacement was 1.7%. Of the 59 (25.3%) late overall deaths, 15 (6.6%) were cardiac-related, and survival rate was 93% at 10 years. At follow-up, 97% of patients were in New York Heart Association class I or II. Actuarial freedom from reoperation due to structural deterioration was 100% at 5 years and 96% at 10 years. Freedom from endocarditis at 10 years was 97%. Mean aortic pressure gradient measured by echocardiography was 11.5 mm Hg at hospital discharge and 10.4 mm Hg at the last follow-up. Conclusions The 3F valve is a user-friendly third-generation stentless aortic prosthesis with proven durability and remarkable hemodynamic performance preserved over time. The 3F is particularly useful in cases of expected patient/prosthesis mismatch more...
- Published
- 2021
- Full Text
- View/download PDF