1. Effect of cataract extraction with intraocular lens implantation in patients with myopia on optical coherence tomography measurements
- Author
-
A.A. Troshina, Shpak Aa, and M.V. Korobkova
- Subjects
Retinal Ganglion Cells ,0301 basic medicine ,medicine.medical_specialty ,genetic structures ,medicine.medical_treatment ,Optic Disk ,Nerve fiber layer ,Glaucoma ,Intraocular lens ,Cataract Extraction ,Retinal ganglion ,Cataract ,03 medical and health sciences ,0302 clinical medicine ,Lens Implantation, Intraocular ,Ophthalmology ,Myopia ,medicine ,Humans ,Dioptre ,business.industry ,Phacoemulsification ,medicine.disease ,eye diseases ,030104 developmental biology ,medicine.anatomical_structure ,030221 ophthalmology & optometry ,Optic nerve ,sense organs ,business ,Tomography, Optical Coherence ,Optic disc - Abstract
One important question for patients with both myopia and glaucoma is comparability of optical coherence tomography (OCT) data obtained before and after a significant change in eye refraction following cataract extraction surgery with implantation of intraocular lens (IOL).To assess the impact of correcting moderate and high myopia during cataract phacoemulsification with IOL implantation (Phaco/IOL) on the parameters measured by OCT.OCT was performed in 31 patients (31 eyes) with axial eye length of more than 25.5 mm before and the day after Phaco/IOL. Changes in 17 parameters of the retina, retinal ganglion cells-inner plexiform layer (GCIPL), peripapillary retinal nerve fiber layer (RNFL) and optic nerve head (ONH) were analyzed.Axial eye length was 26.94±1.09 mm in average (25.57-29.39 mm). The average refractive effect of the intervention was 8.44±4.16 D (3.75-19.0 Diopters). Signal strength in all OCT protocols was no lower than 5. Changes in the average values of OCT parameters after surgery were insignificant. They exceeded 1% of the pre-operation values only in 7 cases, including all 5 parameters of the ONH, and were significant only in 5 out of 17 parameters. For GCIPL and RNFL thickness, the changes on average did not exceed 0.9 μm, for retinal thickness in the macular area - 2.1 μm. In relative terms, the largest decrease (an average of -0.03 mmIn patients with high and moderate myopia, the parameters of the retina, RNFL, GCIPL, and ONH, as measured by OCT, changed insignificantly on the first day after Phaco/IOL (considering the signal strength of Cirrus HD-OCT device was not lower than 5).Введение. При коррекции близорукости, сочетающейся с глаукомой, имеет значение сопоставимость данных оптической когерентной томографии (ОКТ), полученных до и после изменения рефракции глаза в ходе операции экстракции катаракты с имплантацией интраокулярной линзы (ИОЛ). Цель исследования - оценить влияние коррекции миопии средней и высокой степени в ходе операции факоэмульсификации катаракты (ФЭК) с имплантацией ИОЛ (ФЭК+ИОЛ) на показатели, измеряемые методом ОКТ. Материал и методы. ОКТ выполнена у 31 пациента (31 глаз) с длиной оси глаза более 25,5 мм до и на следующий день после ФЭК+ИОЛ. Анализировали изменения 17 параметров сетчатки, слоя ганглиозных клеток сетчатки с внутренним плексиформным слоем (СГКВП), перипапиллярного слоя нервных волокон сетчатки (пСНВС) и диска зрительного нерва (ДЗН). Результаты. Длина оси глаза была в среднем 26,94±1,09 (25,57-29,39) мм. Рефракционный эффект вмешательства составил в среднем 8,44±4,16 (3,75-19,0) дптр. Сила сигнала во всех протоколах ОКТ была не ниже 5. Изменения средних величин показателей ОКТ после операции были весьма незначительными. Лишь в 7 случаях, включая все 5 параметров ДЗН, они превышали 1% от исходной величины и только в 5 из 17 случаев были статистически значимыми. Изменения толщины СГКВП и пСНВС в среднем не превышали 0,9 мкм, толщины сетчатки в макуле - 2,1 мкм. В относительном выражении наибольшим (в среднем (–)0,03 мм
- Published
- 2019
- Full Text
- View/download PDF