1. [Reliability of Selected Parameters of Cycling Ergospirometry from the PowerCube-Ergo Respiratory Gas Analyser].
- Author
-
Hoppe MW, Sperlich B, Baumgart C, Janssen M, and Freiwald J
- Subjects
- Adult, Equipment Design, Equipment Failure Analysis, Female, Humans, Male, Reproducibility of Results, Sensitivity and Specificity, Exercise Test instrumentation, Oxygen Consumption physiology, Physical Endurance physiology, Pulmonary Gas Exchange physiology, Pulmonary Ventilation physiology, Spirometry instrumentation
- Abstract
This study aimed to investigate the reliability of 1) the key parameters of cycling ergospirometry (maximum power output [Pmax] and oxygen uptake [V̇O2peak], ventilatory thresholds 1 [VT 1] and 2 [VT 2], and cycling efficiency [CE] and gross efficiency [GE]), 2) the commonly used parameters to quantify exhaustion (maximum heart rate [HFmax], respiratory quotient [RQmax], blood lactate concentration [BLAmax], and ratings of perceived exhaustion [RPEmax]), and 3) the kinetics of exercise induced gas exchange measurements (oxygen uptake [V̇O2], carbon dioxide output [V̇CO2], and minute ventilation [V̇E]) using the PowerCube-Ergo metabolic system in consideration of international statistical recommendations. 12 women and 12 men (28 ± 4 years; 23.2 ± 2.4 kg/m(2)) performed two cycling tests (20 watt/min) separated by one week. The reliability was calculated based on differences in means (t test and effect sizes), retest correlation (intraclass correlation coefficient [ICC]), and within-subject variation (standard error of measurement [SEM]). Of the key parameters of cycling ergospirometry, an excellent reliability (ICC ≥ 0.969; p = 0.000) and high accuracy (%SEM ≤ 4.6) were found for Pmax, V̇O2peak, and VT 1. Of the most commonly used parameters to quantify exhaustion, an excellent reliability (ICC = 0.922; p = 0.000) and high accuracy (%SEM = 1.0) existed only for HFmax. The gas exchange measurements (V̇O2, V̇CO2 und V̇E) of the PowerCube-Ergo were all excellently reliable (ICC ≥ 0,991; p = 0.000) and the accuracy of V̇O2 (SEM = 0.10 l/min) and V̇E (SEM = 3.13 l/min) fulfilled the quality guidance of exercise physiology laboratories. For future studies and practical purposes, the results are vital for the decision as to whether a difference between two tests represents a true intervention effect or just a measurement error and for the estimation of required sample sizes., (© Georg Thieme Verlag KG Stuttgart · New York.)
- Published
- 2015
- Full Text
- View/download PDF