1. [Resorbable rods and screws for fixation of ankle fractures. A randomized clinical prospective study].
- Author
-
Springer MA, van Binsbergen EA, Patka P, Bakker FC, and Haarman HJ
- Subjects
- Adolescent, Adult, Aged, Ankle Injuries diagnostic imaging, Female, Follow-Up Studies, Fracture Healing physiology, Humans, Male, Middle Aged, Postoperative Complications diagnostic imaging, Prospective Studies, Radiography, Ankle Injuries surgery, Bone Nails, Bone Screws, Fracture Fixation, Internal instrumentation, Polyglycolic Acid
- Abstract
A prospective randomized clinical trial was performed to evaluate the use of self-reinforced absorbable composites (Biofix) in the fixation of ankle fractures. The aim of this study was to demonstrate that fixation with Biofix rods and screws is as good as the standard A.O. fixation. The benefits of Biofix rods and screws are: a reduction in costs since no secondary operation is needed, prevention of stress-shielding and thereby diminishing the risk of bone porosity. Patients aged between 16 and 75 years old with closed, non-comminuted fractures of the lateral and/or medial malleolus and dislocation of the fracture fragments greater than 2 mm were included in the study. 22 patients were treated with Biofix rods and screws and the control group of 19 patients with a standard technique. After 3, 6 and 12 months, rontgenograms were taken. At the same time functional results were evaluated following the criteria of Olerud and Molander. Two patients were withdrawn from the trial for non-medical reasons. 22 patients (12 from the Biofix group, 10 from the AO group) operated two or more years ago were contacted to see if any complications had occurred since they were last seen. In 4 cases a Biofix screw broke down just beneath the head during insertion. This did not result in an insufficient fixation of the fracture. There were no early post-operative complications. The functional and rontgenological results in both groups were equal. In three cases a sterile sinus developed at the site of screw insertion. Biofix rods and screws, made of polylactic acid, are a good alternative for the fixation of fractures of the ankle. The use of resorbable fracture fixation material has the advantage that a second operation to remove osteosynthesis material is not necessary. The long term results are good. There is, however, a possibility of development of tissue reaction to the resorbable material.
- Published
- 1998
- Full Text
- View/download PDF