4 results on '"Fernández-Armenta J"'
Search Results
2. Validation of multiparametric approaches for the prediction of sudden cardiac death in patients with Brugada syndrome and electrophysiological study.
- Author
-
Rodríguez-Mañero M, Baluja A, Hernández J, Muñoz C, Calvo D, Fernández-Armenta J, García-Fernández A, Zorio E, Arce-León Á, Sánchez-Gómez JM, Mosquera-Pérez I, Arias MÁ, Díaz-Infante E, Expósito V, Jiménez-Ramos V, Teijeira E, Cañadas-Godoy MV, Guerra-Ramos JM, Oloriz T, Basterra N, Sousa P, Elices-Teja J, García-Bolao I, González-Juanatey JR, Brugada R, Gimeno JR, Brugada J, and Arbelo E
- Subjects
- Adult, China, Death, Sudden, Cardiac epidemiology, Death, Sudden, Cardiac etiology, Death, Sudden, Cardiac prevention & control, Electrocardiography, Female, Humans, Male, Middle Aged, Risk Assessment, Syncope etiology, Brugada Syndrome complications, Brugada Syndrome diagnosis, Brugada Syndrome therapy, Defibrillators, Implantable adverse effects
- Abstract
Introduction and Objectives: Multiparametric scores have been designed for better risk stratification in Brugada syndrome (BrS). We aimed to validate 3 multiparametric approaches (the Delise score, Sieira score and the Shanghai BrS Score) in a cohort with Brugada syndrome and electrophysiological study (EPS)., Methods: We included patients diagnosed with BrS and previous EPS between 1998 and 2019 in 23 hospitals. C-statistic analysis and Cox proportional hazard regression models were used., Results: A total of 831 patients were included (mean age, 42.8±13.1; 623 [75%] men; 386 [46.5%] had a type 1 electrocardiogram (ECG) pattern, 677 [81.5%] were asymptomatic, and 319 [38.4%] had an implantable cardioverter-defibrillator). During a follow-up of 10.2±4.7 years, 47 (5.7%) experienced a cardiovascular event. In the global cohort, a type 1 ECG and syncope were predictive of arrhythmic events. All risk scores were significantly associated with events. The discriminatory abilities of the 3 scores were modest (particularly when these scores were evaluated in asymptomatic patients). Evaluation of the Delise and Sieira scores with different numbers of extra stimuli (1 or 2 vs 3) did not substantially improve the event prediction c-index., Conclusions: In BrS, classic risk factors such as ECG pattern and previous syncope predict arrhythmic events. The predictive capabilities of the EPS are affected by the number of extra stimuli required to induce ventricular arrhythmias. Scores combining clinical risk factors with EPS help to identify the populations at highest risk, although their predictive abilities remain modest in the general BrS population and in asymptomatic patients., (Copyright © 2021 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
3. Comparative Evaluation of Four Risk Scores for Predicting Mortality in Patients With Implantable Cardioverter-defibrillator for Primary Prevention.
- Author
-
Rodríguez-Mañero M, Abu Assi E, Sánchez-Gómez JM, Fernández-Armenta J, Díaz-Infante E, García-Bolao I, Benezet-Mazuecos J, Andrés Lahuerta A, Expósito-García V, Bertomeu-González V, Arce-León Á, Barrio-López MT, Peinado R, Martínez-Sande L, and Arias MA
- Subjects
- Age Factors, Aged, Aged, 80 and over, Atrial Fibrillation epidemiology, Cause of Death, Creatinine blood, Death, Sudden, Cardiac etiology, Diabetes Mellitus epidemiology, Electric Countershock, Female, Heart Diseases complications, Heart Diseases epidemiology, Humans, Male, Middle Aged, Primary Prevention, Proportional Hazards Models, Renal Insufficiency, Chronic blood, Renal Insufficiency, Chronic epidemiology, Retrospective Studies, Risk Assessment, Smoking epidemiology, Spain epidemiology, Stroke Volume, Death, Sudden, Cardiac prevention & control, Defibrillators, Implantable, Heart Diseases therapy, Mortality
- Abstract
Introduction and Objectives: Several clinical risk scores have been developed to identify patients at high risk of all-cause mortality despite implantation of an implantable cardioverter-defibrillator. We aimed to examine and compare the predictive capacity of 4 simple scoring systems (MADIT-II, FADES, PACE and SHOCKED) for predicting mortality after defibrillator implantation for primary prevention of sudden cardiac death in a Mediterranean country., Methods: A multicenter retrospective study was performed in 15 Spanish hospitals. Consecutive patients referred for defibrillator implantation between January 2010 and December 2011 were included., Results: A total of 916 patients with ischemic and nonischemic heart disease were included (mean age, 62 ± 11 years, 81.4% male). Over 33.4 ± 12.9 months, 113 (12.3%) patients died (cardiovascular origin in 86 [9.4%] patients). At 12, 24, 36, and 48 months, mortality rates were 4.5%, 7.6%, 10.8%, and 12.3% respectively. All the risk scores showed a stepwise increase in the risk of death throughout the scoring system of each of the scores and all 4 scores identified patients at greater risk of mortality. The scores were significantly associated with all-cause mortality throughout the follow-up period. PACE displayed the lowest c-index value regardless of whether the population had heart disease of ischemic (c-statistic = 0.61) or nonischemic origin (c-statistic = 0.61), whereas MADIT-II (c-statistic = 0.67 and 0.65 in ischemic and nonischemic cardiomyopathy, respectively), SHOCKED (c-statistic = 0.68 and 0.66, respectively), and FADES (c-statistic = 0.66 and 0.60) provided similar c-statistic values (P ≥ .09)., Conclusions: In this nontrial-based cohort of Mediterranean patients, the 4 evaluated risk scores showed a significant stepwise increase in the risk of death. Among the currently available risk scores, MADIT-II, FADES, and SHOCKED provide slightly better performance than PACE., (Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
4. [Electrical storm in patients with prophylactic defibrillator implantation].
- Author
-
Rodríguez-Mañero M, González-Cambeiro C, Moreno-Arribas J, Expósito-García V, Sánchez-Gómez JM, González-Torres L, Arce-León Á, Arguedas-Jiménez H, Gaztañaga L, Salvador-Montañés O, Iglesias-Bravo JA, Huerta AA, Fernández-Armenta J, Arias MÁ, and Martínez-Sande L
- Subjects
- Aged, Arrhythmias, Cardiac epidemiology, Electrophysiological Phenomena, Female, Humans, Male, Middle Aged, Prevalence, Retrospective Studies, Tachycardia, Ventricular therapy, Arrhythmias, Cardiac prevention & control, Defibrillators, Implantable
- Abstract
Introduction: Little is known about the prevalence of electrical storm, baseline characteristics and mortality implications of patients with implantable cardioverter defibrillator in primary prevention versus those patients without electrical storm. We sought to assess the prevalence, baseline risk profile and survival significance of electrical storm in patients with implantable defibrillator for primary prevention., Methods: Retrospective multicenter study performed in 15 Spanish hospitals. Consecutives patients referred for desfibrillator implantation, with or without left ventricular lead (at least those performed in 2010 and 2011), were included., Results: Over all 1,174 patients, 34 (2,9%) presented an electrical storm, mainly due to ventricular tachycardia (82.4%). There were no significant baseline differences between groups, with similar punctuation in the mortality risk scores (SHOCKED, MADIT and FADES). A clear trigger was identified in 47% of the events. During the study period (38±21 months), long-term total mortality (58.8% versus 14.4%, p<0.001) and cardiac mortality (52.9% versus 8.6%, p<0.001) were both increased among electrical storm patients. Rate of inappropriate desfibrillator intervention was also higher (14.7 versus 8.6%, p<0.001)., Conclusions: In the present study of patients with desfibrillator implantation for primary prevention, prevalence of electrical storm was 2.9%. There were no baseline differences in the cardiovascular risk profile versus those without electrical storm. However, all cause mortality and cardiovascular mortality was increased in these patients versus control desfibrillator patients without electrical storm, as was the rate of inappropriate desfibrillator intervention., (Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.