30 results on '"Bond testing"'
Search Results
2. Resonance Bond Testing: Theory and Application
- Author
-
James Bittner and Stetson Watkins
- Subjects
Materials science ,Nuclear magnetic resonance ,Mechanics of Materials ,Bond testing ,Mechanical Engineering ,Resonance ,General Materials Science - Abstract
Resonance bond testing is a nondestructive testing (NDT) technique that is used to detect disbonds, delaminations, and other voids in composite materials. The aerospace industry has seen an increase in the use of carbon fiber reinforced plastics (CFRP) for aircraft and spacecraft construction. Composite materials offer many advantages over traditional metallic structures, which include weight savings, increased strength, design for specific load paths, and the ability to easily construct geometrically complex structures. Resonance bond testing has many established uses for metallic structures as well, such as aluminum skin-to-skin and skin-to-core bonds. This bond testing technique has been around for many decades but is used by only a small portion of the NDT community. Ultrasonic testing (UT), specifically phased array ultrasonic testing (PAUT), using linear array techniques has proven to be a reliable method for the inspection of CFRP laminates. When composite structures do not permit the use of high-frequency sound waves due to rapid attenuation, resonance bond testing is a proven alternative. In this paper, the authors will discuss the theory behind resonance bond testing and how it has and continues to play an important role in the NDT industry.
- Published
- 2021
- Full Text
- View/download PDF
3. A Low-Cost, Robust and Tolerant, Digital Scheme for Post-Bond Testing and Diagnosis of TSVs
- Author
-
Alkis A. Hatzopoulos, Vasileios Gerakis, and Yiorgos Tsiatouhas
- Subjects
Scheme (programming language) ,Resistive touchscreen ,Computer science ,Bond testing ,Design for testing ,020208 electrical & electronic engineering ,Process (computing) ,Hardware_PERFORMANCEANDRELIABILITY ,02 engineering and technology ,Integrated circuit ,020202 computer hardware & architecture ,Reliability engineering ,law.invention ,Robustness (computer science) ,law ,Hardware_INTEGRATEDCIRCUITS ,0202 electrical engineering, electronic engineering, information engineering ,Electrical and Electronic Engineering ,computer ,computer.programming_language ,Electronic circuit - Abstract
Through Silicon Vias (TSVs) are crucial elements for the reliable operation and yield of three dimensional integrated circuits (3D ICs). Defects are a serious concern in TSV structures. A post-bond, parallel testing and diagnosis scheme is proposed in this work, for the detection and location of resistive open or short to substrate defects in TSVs, which is based on easily synthesizable all digital testing circuitry. The new testing method provides tolerance over process and temperature variations that may influence the embedded circuits. Extensive typical model simulations and Monte-Carlo analysis results, using the 65 nm technology of TSMC, prove the effectiveness of the new method. Additionally, two representative methods from the literature are simulated and compared to the proposed one, in terms of effectiveness, robustness, tolerance, cost and design for testability effort. The proposed scheme is proven to perform better based on all presented criteria.
- Published
- 2021
- Full Text
- View/download PDF
4. The microtensile bond strength test: Its historical background and application to bond testing
- Author
-
Monica Yamauti, Pipop Saikaew, Shuhei Hoshika, Abu Faem Mohammad Almas Chowdhury, Hidehiko Sano, and Mariko Matsumoto
- Subjects
0301 basic medicine ,Materials science ,Bond testing ,Article ,03 medical and health sciences ,0302 clinical medicine ,stomatognathic system ,Microtensile bond strength test ,Dentin adhesive ,Resin composite ,Caries affected dentin ,Dentin ,medicine ,Composite material ,General Dentistry ,Caries-affected dentin ,Bond strength ,Bond ,030206 dentistry ,Test (assessment) ,lcsh:RK1-715 ,Sclerotic dentin ,030104 developmental biology ,medicine.anatomical_structure ,lcsh:Dentistry ,Adhesion ,Adhesive ,Minimal intervention - Abstract
Summary: Microtensile bond strength (μTBS) test was introduced in 1994. Since then, it has been utilized profoundly across many bond strength testing laboratories, making it currently one of the most standard and versatile bond strength test. Although it is a static and strength-based method, together with the morphological and spectroscopic investigations, it has been contributing immensely in the advancement of dentin adhesive systems. μTBS test has a greater discriminative capability than the traditional macro-shear bond test. During the early stage of its development, the authors predicted that this testing method would enable evaluation of the adhesive performances of resins to excavated carious or sclerotic dentin and the regional bond strengths of various portions of the cavity. In addition, they also stated the possibility of comparing the long-term stability of resin adhesion at various portions of the cavity walls on teeth extracted at various times after insertion of bonded restorations. In this review, we discussed the historical background, inception and the application of the μTBS test and proposed directions for further improvement of this testing method.
- Published
- 2020
- Full Text
- View/download PDF
5. Effect of Jig Design and Assessment of Stress Distribution in Testing Metal-Ceramic Adhesion.
- Author
-
Özcan, Mutlu, Kojima, Alberto Noriyuki, Nishioka, Renato Sussumu, Mesquita, Alfredo Mikail Melo, Bottino, Marco Antonio, and Filho, Gilberto Duarte
- Subjects
CERAMIC metals ,DENTURES ,DENTAL implants ,PATIENT satisfaction ,DENTISTRY - Abstract
Purpose In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the interface, resulting in complex stresses. The jig designs used for this kind of test show variations in published studies, complicating direct comparison between studies. This study evaluated the effect of different jig designs on metal-ceramic bond strength and assessed the stress distribution at the interface using finite element analysis (FEA). Materials and Methods Metal-ceramic (Metal: Ni-Cr, Wiron 99, Bego; Ceramic: Vita Omega 900, Vita) specimens (N = 36) (diameter: 4 mm, veneer thickness: 4 mm; base diameter: 5 mm, thickness: 1 mm) were fabricated and randomly divided into three groups (n = 12 per group) to be tested using one of the following jig designs: (a) chisel (CH) (ISO 11405), (b) steel strip (SS), (c) piston (PI). Metal-ceramic interfaces were loaded under shear until debonding in a universal testing machine (0.5 mm/min). Failure types were evaluated using scanning electron microscopy (SEM). FEA was used to study the stress distribution using different jigs. Metal-ceramic bond strength data (MPa) were analyzed using ANOVA and Tukey's tests (α = 0.05). Results The jig type significantly affected the bond results ( p = 0.0001). PI type of jig presented the highest results (MPa) ( p < 0.05) (58.2 ± 14.8), followed by CH (38.7 ± 7.6) and SS jig type (23.3 ± 4.2) ( p < 0.05). Failure types were exclusively a combination of cohesive failure in the opaque ceramic and adhesive interface failure. FEA analysis indicated that the SS jig presented slightly more stress formation than with the CH jig. The PI jig presented small stress concentration with more homogeneous force distribution compared to the CH jig where the stress concentrated in the area where the force was applied. Conclusion Metal-ceramic bond strength was affected by the jig design. Accordingly, the results of in vitro studies on metal-ceramic adhesion should be evaluated with caution. Clinical significance: When adhesion of ceramic materials to metals is evaluated in in vitro studies, it should be noted that the loading jig type affects the results. Clinical observations should report on the location and type of ceramic fractures in metal-ceramic reconstructions so that the most relevant test method can be identified. [ABSTRACT FROM AUTHOR]
- Published
- 2016
- Full Text
- View/download PDF
6. Are demographic correlates of white-faced capuchin monkey (Cebus capucinus) 'Gargle and Twargle' vocalization rates consistent with the infanticide risk assessment hypothesis?
- Author
-
Daniel G. Edelberg, Alexa Duchesneau, and Susan Perry
- Subjects
0106 biological sciences ,Costa Rica ,Male ,Bond testing ,Population ,010603 evolutionary biology ,01 natural sciences ,Risk Assessment ,White-faced capuchin ,biology.animal ,Cebus capucinus ,Medicine ,Animals ,Cebus ,0501 psychology and cognitive sciences ,050102 behavioral science & comparative psychology ,education ,Ecology, Evolution, Behavior and Systematics ,Demography ,High rate ,education.field_of_study ,Reproductive success ,biology ,business.industry ,Repertoire ,05 social sciences ,Animal Science and Zoology ,Female ,Vocalization, Animal ,Risk assessment ,business - Abstract
Zahavi's "Bond Testing Hypothesis" states that irritating stimuli are used to elicit honest information from social partners regarding their attitudes towards the relationship. Two elements of the Cebus capucinus vocal repertoire, the "gargle" and "twargle," have been hypothesized to serve such a bond-testing function. The greatest threat to C. capucinus infant survival, and to adult female reproductive success, is infanticide perpetrated by alpha males. Thus, we predicted that infants (
- Published
- 2021
7. Pull-Out Behavior of CFRP Bars in Glued-In Glubam Joints
- Author
-
B. Shan, Z. W. He, C. Q. Chen, and Yan Xiao
- Subjects
Materials science ,Structural material ,Bar (music) ,Bond testing ,Mechanical Engineering ,0211 other engineering and technologies ,020101 civil engineering ,02 engineering and technology ,Building and Construction ,Fibre-reinforced plastic ,0201 civil engineering ,Connection (mathematics) ,Mechanics of Materials ,021105 building & construction ,Ceramics and Composites ,Composite material ,Civil and Structural Engineering - Abstract
Glubam (glued-laminated bamboo) is a newly developed structural material with properties comparable to other wood and wood-based materials. Fiber-reinforced polymer (FRP) bar is an attract...
- Published
- 2021
- Full Text
- View/download PDF
8. A Concise Review on Interlayer Bond Strength in 3D Concrete Printing
- Author
-
Biranchi Panda, Adewumi John Babafemi, Suvash Chandra Paul, John Temitope Kolawole, and Jihad Miah
- Subjects
3d printed ,Materials science ,interlayer bond strength ,Geography, Planning and Development ,0211 other engineering and technologies ,3D printing ,TJ807-830 ,02 engineering and technology ,Management, Monitoring, Policy and Law ,TD194-195 ,3D concrete printing ,Renewable energy sources ,mechanical interlocking ,021105 building & construction ,bond testing ,characterization ,GE1-350 ,Composite material ,Interlocking ,Measurement method ,Environmental effects of industries and plants ,Renewable Energy, Sustainability and the Environment ,business.industry ,Bond strength ,021001 nanoscience & nanotechnology ,Microstructure ,Durability ,Characterization (materials science) ,Environmental sciences ,0210 nano-technology ,business - Abstract
Interlayer bond strength is one of the key aspects of 3D concrete printing. It is a well-established fact that, similar to other 3D printing process material designs, process parameters and printing environment can significantly affect the bond strength between layers of 3D printed concrete. The first section of this review paper highlights the importance of bond strength, which can affect the mechanical and durability properties of 3D printed structures. The next section summarizes all the testing and bond strength measurement methods adopted in the literature, including mechanical and microstructure characterization. Finally, the last two sections focus on the influence of critical parameters on bond strength and different strategies employed in the literature for improving the strength via strengthening mechanical interlocking in the layers and tailoring surface as well as interface reactions. This concise review work will provide a holistic perspective on the current state of the art of interlayer bond strength in 3D concrete printing process.
- Published
- 2021
9. Investigating failure behavior and origins under supposed “shear bond” loading.
- Author
-
Sultan, Hassam, Kelly, J. Robert, and Kazemi, Reza B.
- Subjects
- *
DENTIN , *GUMS & resins , *SILICON carbide , *COMPOSITE materials , *SURFACE analysis , *SHEARING force - Abstract
Purpose This study evaluated failure behavior when resin-composite cylinders bonded to dentin fractured under traditional “shear” testing. Failure was assessed by scaling of failure loads to changes in cylinder radii and fracture surface analysis. Three stress models were examined including failure by: bonded area; flat-on-cylinder contact; and, uniformly-loaded, cantilevered-beam. Methods Nine 2-mm dentin occlusal dentin discs for each radii tested were embedded in resin and bonded to resin-composite cylinders; radii (mm) = 0.79375; 1.5875; 2.38125; 3.175. Samples were “shear” tested at 1.0 mm/min. Following testing, disks were finished with silicone carbide paper (240–600 grit) to remove residual composite debris and tested again using different radii. Failure stresses were calculated for: “shear”; flat-on-cylinder contact; and, bending of a uniformly-loaded cantilevered beam. Stress equations and constants were evaluated for each model. Fracture-surface analysis was performed. Results Failure stresses calculated as flat-on-cylinder contact scaled best with its radii relationship. Stress equation constants were constant for failure from the outside surface of the loaded cylinders and not with the bonded surface area or cantilevered beam. Contact failure stresses were constant over all specimen sizes. Fractography reinforced that failures originated from loaded cylinder surface and were unrelated to the bonded surface area. Conclusions “Shear bond” testing does not appear to test the bonded interface. Load/area “stress” calculations have no physical meaning. While failure is related to contact stresses, the mechanism(s) likely involve non-linear damage accumulation, which may only indirectly be influenced by the interface. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
10. Heuristic Approach for Identification of Random TSV Defects in 3D IC During Pre-bond Testing
- Author
-
G P Biswas, Tanusree Kaibartta, and Debesh K. Das
- Subjects
Interconnection ,Computer science ,Heuristic (computer science) ,Bond testing ,0211 other engineering and technologies ,Three-dimensional integrated circuit ,021107 urban & regional planning ,02 engineering and technology ,Integrated circuit ,020202 computer hardware & architecture ,Reliability engineering ,law.invention ,Identification (information) ,3d integrated circuit ,Power consumption ,law ,0202 electrical engineering, electronic engineering, information engineering - Abstract
The possibility of 3D integrated circuit (3D IC) has been considered as a choice to overcome the difficulties faced by two-dimensional integrated circuits (2D IC). Several technologies exist to connect the layers in 3D IC. Among these technologies through-silicon vias (TSVs) is the promising one since it helps to reduce interconnect length, delays and power consumption. In spite of the advantages it introduces different types of defects which ultimately make an entire IC faulty. Thus, testing of TSVs is an important necessity. Depending on the timing, the testing may be of two types -pre-bond and post-bond. In pre-bond TSV testing TSVs are tested in sessions. In this paper our objective is to reduce the pre-bond TSV test sessions as much as possible, so that overall testing time decreases. To reduce test sessions we need to reduce the individual TSV testing and increase group wise TSV testing.
- Published
- 2020
- Full Text
- View/download PDF
11. Direct Shear Bond Tests of Fabric-Reinforced Cementitious Matrix Materials
- Author
-
Carlo Poggi, Francesca Giulia Carozzi, Diana Arboleda, and Antonio Nanni
- Subjects
Materials science ,Bond testing ,Mechanical Engineering ,Bond ,0211 other engineering and technologies ,020101 civil engineering ,02 engineering and technology ,Building and Construction ,0201 civil engineering ,Mechanics of Materials ,021105 building & construction ,Ceramics and Composites ,Fiber ,Direct shear test ,Composite material ,Mortar ,Cementitious matrix ,Civil and Structural Engineering - Abstract
Fabric-reinforced cementitious matrix (FRCM) composites consist of a dry fiber fabric embedded in an inorganic mortar that may be enriched with short fibers. These composites are particular...
- Published
- 2020
- Full Text
- View/download PDF
12. Microshear bond strength of different restorative materials to teeth with molar-incisor-hypomineralisation (MIH): a pilot study
- Author
-
E Al-Sarraf, M Al-Shammari, Muawia A. Qudeimat, and M Arab
- Subjects
Dental Stress Analysis ,Molar ,Adolescent ,Bond testing ,Glass ionomer cement ,Dentistry ,Pilot Projects ,In Vitro Techniques ,Resin-Based Composite ,Composite Resins ,Molar incisor hypomineralisation ,03 medical and health sciences ,0302 clinical medicine ,Humans ,Medicine ,Dentistry (miscellaneous) ,030212 general & internal medicine ,Child ,Dental Restoration, Permanent ,Acrylic resin ,Enamel paint ,business.industry ,Bond strength ,Dental Bonding ,030206 dentistry ,Glass Ionomer Cements ,visual_art ,Pediatrics, Perinatology and Child Health ,visual_art.visual_art_medium ,Dental Enamel Hypoplasia ,Shear Strength ,business - Abstract
To compare the microshear bond strength of resin based composite (RBC) and resin modified glass ionomer cement (RMGIC) restorations when bonded to teeth with molar incisor hypomineralisation (MIH). Eleven first permanent molars with MIH were included in this study. Teeth were sectioned mesio-distally producing a total of 22 surfaces for testing. Each specimen was placed inside a plastic ring with the flattened surface in contact with a glass slab. The plastic ring was filled with autopolymerising acrylic resin to imbed the specimen leaving the enamel surface exposed. Each surface was then bonded to 0.96 mm diameter RBC and light cured RMGIC following the manufacturers’ instructions. Microshear bond testing was performed after 24 h storage in distilled water at 37 °C. A Bisco shear tester was used to apply shear stress of 1 mm/min until failure. Wilcoxon signed-rank paired-test was used for comparison of bond strength values. Microshear bond strength of RBC (30.80 ± 8.19 MPa) was significantly higher than that of RMGIC (11.13 ± 6.91 MPa) when bonded to hypomineralised permanent first molars (p
- Published
- 2018
- Full Text
- View/download PDF
13. Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature
- Author
-
Aminah M. El Mourad
- Subjects
Micro-tensile ,Bond testing ,Computer science ,0206 medical engineering ,Adhesive ,02 engineering and technology ,Push-out ,03 medical and health sciences ,Adhesive materials ,0302 clinical medicine ,Ultimate tensile strength ,Tensile ,General Dentistry ,Stress concentration ,Bond strength ,business.industry ,Bond ,Clinical performance ,Shear ,030206 dentistry ,Structural engineering ,020601 biomedical engineering ,Micro-shear ,Dentistry ,business ,Micro- push-out - Abstract
Background: The rapid developments in the field of adhesive dental materials have led to improvements in many aspects of clinical dentistry. Adhesive bond strength plays an important role in determining the clinical performance and longevity of dental restorations. Nevertheless, bond strength tests have never been well-standardized, although a number of important recommendations have been made. Objective: The aim of this paper is to critically review the validity of different bond strength testing methods for assessment of bonding effectiveness of adhesive materials to tooth structure and discuss factors that may affect bond strength measurement. Data Collection: Relevant literature published between 1983 and 2018 was collected and reviewed from the PubMed database and Google scholar resources. Review Results: Results of the current bond testing methods should be used to compare materials tested under the same laboratory settings, but they shouldn’t be used to make direct inferences on their clinical behaviour. Shear and micro-shear tests, result in non-uniform stress distribution, stress concentration at the substrate area, and predominantly tensile stresses rather than shear stresses. Micro-tensile bond tests provide many advantages over the shear tests, although these methods are technique sensitive and labour intensive. Conclusion: Bond strength testing methods should be well-standardized, but there are many factors that cannot be fully controlled which leads to variation and misinterpretation of the data about the bonding abilities of adhesives. Clinical Significance: New adhesive materials should be subjected to a combination of testing protocols to properly assess their bonding effectiveness.
- Published
- 2018
- Full Text
- View/download PDF
14. Effect of sodium metabisulfite gel on the bond strength of dentin of bleached teeth
- Author
-
Débora Alves Nunes Leite Lima, José Roberto Lovadino, Thayla Hellen Nunes Gouveia, Flávio Henrique Baggio Aguiar, Henrique Heringer Vieira, Anderson Catelan, and José Carlos de Toledo
- Subjects
bond strength ,Chromatography ,Enamel paint ,Bond testing ,Bond strength ,free radicals ,030206 dentistry ,Sodium metabisulfite ,Application time ,030207 dermatology & venereal diseases ,03 medical and health sciences ,chemistry.chemical_compound ,0302 clinical medicine ,medicine.anatomical_structure ,chemistry ,visual_art ,visual_art.visual_art_medium ,Dentin ,medicine ,Original Article ,Statistical analysis ,microshear ,Antioxidant ,Hydrogen peroxide ,General Dentistry - Abstract
Objective: This study aimed to evaluate the effect of the application of sodium metabisulfite (SMB) on the bond strength of bleached teeth. Materials and Methods: The study was divided into two parts. The first part evaluated the application of various concentrations of SMB for 1 h prior to the completion of bonding procedures. Fifty blocks were divided into five groups (n = 10): control; bleaching with 35% hydrogen peroxide (HP); HP + 5% SMB; HP + 12.5% SMB; and HP + 25% SMB. The second part evaluated the application of 25% gel SMB to either enamel or dentin, including the application time. Sixty blocks were divided into six groups (n = 10): control; bleaching with 35% HP; HP + 25% SMB for 1 h in enamel; HP + 25% SMB for 1 h in dentin; HP + 25% SMB for 10 min in enamel; and HP + 25% SMB for 10 min in dentin. Statistical Analysis: Following the completion of microshear bond testing, data were analyzed using one-way analysis of variance as well as Tukey's and Dunnett's tests. Results: In part 1, data analysis revealed statistical differences (P < 0.0001) between HP and HP + 5% SMB. No statistical differences were found between the control and both HP + 12.5% SMB and HP + 25% SMB. Part 2 revealed a statistical difference (P = 0.001359) only between the bleached group and others. Conclusions: The use of 25% SMB gel immediately after bleaching was able to reverse the deleterious effect of bleaching on the bond strength of dental composites to dentin.
- Published
- 2018
- Full Text
- View/download PDF
15. Active Microwave Thermography: A Real-Time Monitoring Tool for CFRP-Concrete Bond Testing
- Author
-
Lesley H. Sneed, Kristen M. Donnell, Xingxing Zou, Mohammad Tayeb Ghasr, and Ali Mirala
- Subjects
Bond testing ,business.industry ,020208 electrical & electronic engineering ,Composite number ,0211 other engineering and technologies ,Mechanical engineering ,02 engineering and technology ,Nondestructive testing ,Long period ,021105 building & construction ,Thermography ,0202 electrical engineering, electronic engineering, information engineering ,Medicine ,Monitoring tool ,business ,Microwave ,Thermal energy - Abstract
Nondestructive testing and evaluation (NDT&E) of materials and structures is important for many civil and infrastructure applications. To this end, this paper introduces active microwave thermography (AMT) as a real-time monitoring tool for detection of defect formation and propagation in composite-strengthened concrete structures. AMT is a thermographic NDT&E technique which utilizes microwave radiation as a heat source. In this case, AMT is used to detect and evaluate debonding in a number of concrete specimens which have been strengthened with externally bonded carbon-fiber-reinforced polymer (CFRP) composite. As microwave radiation can be constantly and continuously applied over a long period of time, it can be effectively used as a source of thermal energy for long inspections. Several measurement results are presented in the paper that support AMT as a successful monitoring tool for the aforementioned application.
- Published
- 2019
- Full Text
- View/download PDF
16. Pre‐bond testing through direct probing of large‐array fine‐pitch micro‐bumps
- Author
-
Marinissen, Erik Jan, De Wachter, Bart, Kiesewetter, Jörg, Smith, Ken, Franzon, P.D., Marinissen, E.J., Bakir, M.S., and Electronic Systems
- Subjects
Interconnection ,Stack (abstract data type) ,Bond testing ,Computer science ,law ,Large array ,Stacking ,Electronic engineering ,Fine pitch ,Integrated circuit ,Application time ,law.invention - Abstract
In order to obtain acceptable compound stack yields for 2.5D‐ and 3D‐stacked integrated circuits (SICs), there is a need to test the constituting dies before stacking. The non‐bottom dies of these stacks have their functional access exclusively through large arrays of fine‐pitch micro‐bumps, which are too dense for conventional probe technology. A common approach to obtain pre‐bond test access is to equip these dies with dedicated pre‐bond probe pads, which comes with drawbacks such as increased silicon area and test application time and reduced interconnect performance. In order to avoid the many drawbacks of dedicated pre‐bond probe pads, we advocate the usage of advanced probe technology that allows to directly probe on these micro‐bumps. This chapter reports on the technical feasibility of this approach. The economical feasibility is addressed in Chapter 9.
- Published
- 2019
- Full Text
- View/download PDF
17. Efficient Pre-Bond Testing of TSV Defects Based on IEEE std. 1500 Wrapper Cells
- Author
-
Dooyoung Kim, Sungju Park, Muhammad Adil Ansari, and Jihun Jung
- Subjects
010302 applied physics ,Engineering ,business.industry ,Bond testing ,Clock rate ,Integrity testing ,ComputerApplications_COMPUTERSINOTHERSYSTEMS ,Hardware_PERFORMANCEANDRELIABILITY ,02 engineering and technology ,Test method ,01 natural sciences ,020202 computer hardware & architecture ,Electronic, Optical and Magnetic Materials ,Ic manufacturing ,Embedded system ,0103 physical sciences ,Hardware_INTEGRATEDCIRCUITS ,0202 electrical engineering, electronic engineering, information engineering ,Electronic engineering ,Hardware_ARITHMETICANDLOGICSTRUCTURES ,Electrical and Electronic Engineering ,business - Abstract
The yield of 3D stacked IC manufacturing improves with the pre-bond integrity testing of through silicon vias (TSVs). In this paper, an efficient pre-bond test method is presented based on IEEE std. 1500, which can precisely diagnose any happening of TSV defects. The IEEE std. 1500 wrapper cells are augmented for the proposed method. The pre-bond TSV test can be performed by adjusting the driving strength of TSV drivers and the test clock frequency. The experimental results show the advantages of the proposed approach.
- Published
- 2016
- Full Text
- View/download PDF
18. Recommendation of RILEM TC 241-MCD on Interface Debonding Testing in Pavements
- Author
-
Christiane Raab, Christophe Petit, Armelle Chabot, A. Destrée, Université de Limoges (UNILIM), Laboratoire Auscultation, Modélisation, Expérimentation des infrastructures de transport (IFSTTAR/MAST/LAMES), PRES Université Nantes Angers Le Mans (UNAM)-Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR), Belgian Road Research Center, parent, Swiss Federal Laboratories for Materials Science and Technology [Thun] (EMPA), RP2-S12002: Opération recherche FISSURES (IFSTTAR), RILEM, and Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR)-PRES Université Nantes Angers Le Mans (UNAM)
- Subjects
Engineering ,CHAUSSEE ,Bond testing ,0211 other engineering and technologies ,020101 civil engineering ,INTERLAYER BOND TESTS ,02 engineering and technology ,DECOLLEMENT ,0201 civil engineering ,FISSURATION ,[PHYS.MECA.MEMA]Physics [physics]/Mechanics [physics]/Mechanics of materials [physics.class-ph] ,021105 building & construction ,Forensic engineering ,General Materials Science ,Technical committee ,Civil and Structural Engineering ,Task group ,TEST ,business.industry ,Building and Construction ,State of the art review ,[PHYS.MECA]Physics [physics]/Mechanics [physics] ,[PHYS.MECA.MSMECA]Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph] ,Mixed mode ,INTERFACE ,Cracking ,PAVEMENT ,DEBONDING ,Mechanics of Materials ,Asphalt ,business - Abstract
International audience; The following recommendations are based on the chapter III of a State of the Art review conducted by the Task Group 2 of the RILEM Technical Committee 241-MCD 'Mechanisms of cracking and debonding in asphalt and composite pavements' (Petit et al in Mechanisms of cracking and debonding in asphalt and composite pavements. Chapter III of the State-of-the-Art report of the RILEM technical committee 241-MCD series, vol 28. Springer, New York, pp 103-154. ISBN 978-3-319-76848-9 2018). The recommendations mostly concern 'pure' fracture mode test methods that are currently used worldwide and even standardized, while mixed mode test methods developed by few research teams have not received full attention. This paper intends to give guidance for the application and characterization of interlayer bond testing, looking at the appropriate test methods and the importance of influencing parameters.
- Published
- 2018
- Full Text
- View/download PDF
19. Pre-bond Testing of TSVs in 3D IC Using Segmented Cellular Automata
- Author
-
Bidesh Chakraborty and Mamata Dalui
- Subjects
Correctness ,business.industry ,Computer science ,Bond testing ,Three-dimensional integrated circuit ,Test method ,Cellular automaton ,Fault detection and isolation ,symbols.namesake ,symbols ,Segmentation ,business ,Computer hardware ,Von Neumann architecture - Abstract
Pre-bond testing of through silicon vias (TSVs) in 3D ICs is very challenging task. Reliability and correctness of 3D ICs consisting of numbers of TSVs have to be established. This paper presents an innovative pre-bond test method for TSVs in a 3D IC. The logic is devised around the cascadable arrangement of Cellular Automata (CA), discovered by von Neumann in the year of 1960. SACA, a designated class of CA, has been developed to diagnose conductor and insulator defects in TSVs. The segmentation of CA in the design assures more effectiveness, with respect to the number of computations to identify faulty TSVs. The implemented hardware realizes quick test of manufacturing TSV faults in the pre-bond phase.
- Published
- 2018
- Full Text
- View/download PDF
20. A Concise Review on Interlayer Bond Strength in 3D Concrete Printing.
- Author
-
Babafemi, Adewumi John, Kolawole, John Temitope, Miah, Md Jihad, Paul, Suvash Chandra, and Panda, Biranchi
- Abstract
Interlayer bond strength is one of the key aspects of 3D concrete printing. It is a well-established fact that, similar to other 3D printing process material designs, process parameters and printing environment can significantly affect the bond strength between layers of 3D printed concrete. The first section of this review paper highlights the importance of bond strength, which can affect the mechanical and durability properties of 3D printed structures. The next section summarizes all the testing and bond strength measurement methods adopted in the literature, including mechanical and microstructure characterization. Finally, the last two sections focus on the influence of critical parameters on bond strength and different strategies employed in the literature for improving the strength via strengthening mechanical interlocking in the layers and tailoring surface as well as interface reactions. This concise review work will provide a holistic perspective on the current state of the art of interlayer bond strength in 3D concrete printing process. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
21. An Optimization Mechanism for Mid-Bond Testing of TSV-Based 3D SoCs
- Author
-
Zhigang Yu, Kele Shen, and Zhou Jiang
- Subjects
Computer science ,Bond testing ,Chemical physics ,020204 information systems ,0202 electrical engineering, electronic engineering, information engineering ,02 engineering and technology ,Electrical and Electronic Engineering ,Mechanism (sociology) ,020202 computer hardware & architecture ,Electronic, Optical and Magnetic Materials - Published
- 2016
- Full Text
- View/download PDF
22. The Effect of Surface Treatments on the Bond Strength Between CAD/CAM Blocks and Composite Resin
- Author
-
Nilgün Akgül, Omer Sagsoz, Nurdan Polat Sagsoz, Mustafa Duzyol, and Mehmet Yildiz
- Subjects
Universal testing machine ,Materials science ,Bond strength ,Bond testing ,Composite number ,030206 dentistry ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Silane ,03 medical and health sciences ,chemistry.chemical_compound ,0302 clinical medicine ,Hydrofluoric acid ,chemistry ,visual_art ,Nano ,visual_art.visual_art_medium ,Ceramic ,Composite material ,0210 nano-technology ,General Dentistry - Abstract
Purpose The aim of this study was to evaluate the microtensile bond strength of three computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three surface treatment techniques. Methods and Materials Three different CAD/CAM blocks were used in this study: (1) Lithium disilicate, (2) feldspar ceramic, and (3) resin nano ceramic. All groups were further divided into four subgroups according to surface treatment: control, roughened with bur (B); roughened with bur and 5% Hydrofluoric acid (HF); roughened with bur and sandblasting (HF); and roughened with bur and CoJet (C). After surface treatments on each group, a silane and bonding agent were applied, and ceramics were repaired with a nano-hybrid composite. Then, the repaired ceramics were cut with a low-speed diamond saw for microtensile bond testing. Microtensile bond tests for 40 specimens per subgroup were carried out with a universal testing machine. The data were analyzed with ANOVA, Tukey's, and LSD at the 95% significance level. Results Mean bond strengths (MPa) of subgroups B, HF, S, and C were: 0, 29.8, 0, 23.3 for lithium disilicate ceramic; 26.4, 22.3, 22.4, 22 for feldspar ceramic; 54.8, 25.3, 42.1, 25.7 for resin nano ceramic. For subgroups B and S of lithium disilicate ceramics, bonding failed during specimen preparation. No significant differences were observed among all CoJet groups. In subgroups B and S, resin nano ceramics showed the highest bond strength. In feldspar groups, subgroup B showed higher bond strength than the other subgroups. Conclusion This study demonstrates that lithium disilicate porcelain blocks required etching for repairing with composite material. Surface treatments did not increase the bond strength in feldspar ceramic groups and reduced the bond strength in resin nano ceramic groups.
- Published
- 2015
- Full Text
- View/download PDF
23. Identification of Faulty TSVs in 3D IC During Pre-Bond Testing
- Author
-
Surajit Kumar Roy, Chandan Giri, and Dilip Kumar Maity
- Subjects
Bond testing ,Heuristic (computer science) ,Computer science ,020208 electrical & electronic engineering ,Process (computing) ,Three-dimensional integrated circuit ,Hardware_PERFORMANCEANDRELIABILITY ,02 engineering and technology ,Integrated circuit ,Padding ,020202 computer hardware & architecture ,Reliability engineering ,law.invention ,Identification (information) ,law ,Hardware_INTEGRATEDCIRCUITS ,0202 electrical engineering, electronic engineering, information engineering ,Time complexity - Abstract
Manufacturing of three-dimensional (3D) integrated circuit (IC) using through-silicon vias (TSVs) passes through a complex process and testing of TSVs is a critical issue to the researchers. Pre-bond testing eliminates bad dies before bonding. In this paper, we propose a heuristic approach for pre-bond TSV testing which reduces the test time considerably. The proposed method uses recursive bi-partitioning and padding of test sessions and runs in linear time.
- Published
- 2018
- Full Text
- View/download PDF
24. Static and cyclic evaluation of interlayer bonding
- Author
-
Christiane Raab, Manfred N. Partl, A.O. Abd El Halim, and E. Fourquet
- Subjects
Bond testing ,business.industry ,Computer science ,Structural engineering ,business - Abstract
Although static interlayer bond testing has been established for quality control during recent years its significance has been questioned and in the wake of this discussion several more realistic cyclic testing devices have been proposed. The Germany testing device developed at the University of Dresden even found entrance into the European test standards and the device has been commercially available for a couple of years. The paper presents an investigation dealing with the importance of interlayer bond testing for performance evaluation and focuses on a comparison of results from static and cyclic interlayer bond testing. Based on the comparison of static and cyclic bond testing the benefits from cyclic testing will be evaluated and a recommendation for the cyclic testing procedure will be presented.
- Published
- 2017
- Full Text
- View/download PDF
25. Assessment of Interlayer Bonding Properties with Static and Dynamic Devices
- Author
-
Manfred N. Partl, Omar Abd El Halim, Elise Fourquet, and Christiane Raab
- Subjects
Bond testing ,Computer science ,Bond properties ,media_common.quotation_subject ,Service life ,Quality (business) ,Reliability engineering ,Dynamic testing ,media_common - Abstract
Although static interlayer bond testing has been established for quality control during recent years its significance has been questioned and in the wake of this discussion several more realistic dynamic testing devices have been proposed with the purpose of determining the interlayer bond properties not only at failure but also during service life. The Germany testing device developed at the University of Dresden even found entrance into the European test standards and the device has been commercially available for a couple of years. The paper presents an investigation dealing with the importance of interlayer bond testing for performance evaluation and focuses on a comparison of results from static and dynamic interlayer bond testing. Based on the comparison of static and dynamic bond testing the benefits from dynamic testing will be evaluated and a recommendation for the dynamic testing procedure will be presented.
- Published
- 2017
- Full Text
- View/download PDF
26. No-waiting dentine self-etch concept-Merit or hype
- Author
-
Li Na Niu, Xue qing Huang, Tao Luo, César Rogério Pucci, David H. Pashley, Lorenzo Breschi, Franklin Chi Meng Tay, Sun Yat-sen University, Universidade Estadual Paulista (Unesp), Stomatology Hospital of Guangzhou Medical University, University of Bologna – Alma Mater Studiorum, Augusta University, The Fourth Military Medical University, Huang, Xue-qing, Pucci, Cã©sar R., Luo, Tao, Breschi, Lorenzo, Pashley, David H., Niu, Li-na, and Tay, Franklin R.
- Subjects
Curing Lights, Dental ,Materials science ,Time Factors ,Bond testing ,Surface Properties ,Dentistry ,Dental Cements ,02 engineering and technology ,User friendliness ,Time factor ,Composite Resins ,Application time ,03 medical and health sciences ,Dental Materials ,0302 clinical medicine ,stomatognathic system ,Acid Etching, Dental ,Microscopy, Electron, Transmission ,Tensile Strength ,Materials Testing ,Humans ,Composite material ,General Dentistry ,Tooth Demineralization ,Dental Leakage ,business.industry ,Bond strength ,Time factors ,Dentine ,Dental Bonding ,Temperature ,030206 dentistry ,Hydrogen-Ion Concentration ,021001 nanoscience & nanotechnology ,Universal adhesives ,Self etch ,Dentin-Bonding Agents ,Universal adhesive ,Dentin ,Methacrylates ,Molar, Third ,Adhesive ,Stress, Mechanical ,0210 nano-technology ,business ,Self-etch - Abstract
Made available in DSpace on 2018-12-11T17:12:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2017-07-01 National Natural Science Foundation of China Objective A recently-launched universal adhesive, G-Premio Bond, provides clinicians with the alternative to use the self-etch technique for bonding to dentine without waiting for the adhesive to interact with the bonding substrate (no-waiting self-etch; Japanese brochure), or after leaving the adhesive undisturbed for 10 s (10-s self-etch; international brochure). The present study was performed to examine in vitro performance of this new universal adhesive bonded to human coronal dentine using the two alternative self-etch modes. Methods One hundred and ten specimens were bonded using two self-etch application modes and examined with or without thermomechanical cycling (10,000 thermal cycles and 240,000 mechanical cycles) to simulate one year of intraoral functioning. The bonded specimens were sectioned for microtensile bond testing, ultrastructural and nanoleakage examination using transmission electron microscopy. Changes in the composition of mineralised dentine after adhesive application were examined using Fourier transform infrared spectroscopy. Results Both reduced application time and thermomechanical cycling resulted in significantly lower bond strengths, thinner hybrid layers, and significantly more extensive nanoleakage after thermomechanical cycling. Using the conventional 10-s application time improved bonding performance when compared with the no-waiting self-etch technique. Nevertheless, nanoleakage was generally extensive under all testing parameters employed for examining the adhesive. Conclusion Although sufficient bond strength to dentine may be achieved using the present universal adhesive in the no-waiting self-etch mode that does not require clinicians to wait prior to polymerisation of the adhesive, this self-etch concept requires further technological refinement before it can be recommended as a clinical technique. Clinical significance Although the surge for cutting application time to increase user friendliness remains the most frequently sought conduit for advancement of dentine bonding technology, the use of the present universal adhesive in the no-waiting self-etch mode may not represent the best use of the adhesive. Department of Prosthodontics Guanghua School and Hospital of Stomatology & Guangdong Provincial Key Laboratory of Stomatology Sun Yat-sen University Department of Restorative Dentistry Institute of Science and Technology São Paulo State University UNESP São Jose dos Campos Key Laboratory of Oral Medicine Guangzhou Institute of Oral Disease Stomatology Hospital of Guangzhou Medical University Department of Biomedical and Neuromotor Sciences DIBINEM University of Bologna – Alma Mater Studiorum College of Graduate Studies Augusta University State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Oral Diseases School of Stomatology The Fourth Military Medical University Department of Restorative Dentistry Institute of Science and Technology São Paulo State University UNESP São Jose dos Campos National Natural Science Foundation of China: 2015A030401035 National Natural Science Foundation of China: 81400555 National Natural Science Foundation of China: 81500883
- Published
- 2017
27. Predicting Behavior of Grouted Dowel Connections Using Interfacial Cohesive Elements
- Author
-
Faouzi Ghrib, M. Elsayed, and Moncef L. Nehdi
- Subjects
Bond testing ,Computer science ,Constitutive equation ,0211 other engineering and technologies ,020101 civil engineering ,02 engineering and technology ,Dowel ,Slip (materials science) ,bond–slip ,lcsh:Technology ,0201 civil engineering ,lcsh:Chemistry ,Precast ,Precast concrete ,021105 building & construction ,General Materials Science ,Reinforcement ,Spurious relationship ,lcsh:QH301-705.5 ,Instrumentation ,Fluid Flow and Transfer Processes ,cohesive ,model ,lcsh:T ,business.industry ,Process Chemistry and Technology ,General Engineering ,dowel ,Structural engineering ,connections ,lcsh:QC1-999 ,Finite element method ,Computer Science Applications ,lcsh:Biology (General) ,lcsh:QD1-999 ,lcsh:TA1-2040 ,grouted ,finite elements ,lcsh:Engineering (General). Civil engineering (General) ,business ,lcsh:Physics - Abstract
Grouted dowel connections are used extensively in precast load bearing walls owing to their simple construction and forgiving tolerances. Current design guidelines do not adequately consider the composite nature of such connections. Moreover, robust numerical models for these connections are yet to be developed. Therefore, a finite element model of grouted dowel connections was developed in this paper. The model adopts a phenomenological bond&ndash, slip constitutive law to predict the load versus slip response of grouted bars and considers tensile yielding of the reinforcement. The local bond&ndash, slip law used was generated from carefully designed experiments to eliminate spurious effects associated with bond testing. The model was validated using experimental results on grouted connections, as well as data retrieved from the open literature. Excellent agreement between experimental and numerical results was observed, highlighting the accuracy of the model in depicting interfacial stresses of the assembly. The model requires simple calibration, is computationally efficient, and can accurately simulate the failure behavior of bars embedded in grouted connections.
- Published
- 2019
- Full Text
- View/download PDF
28. Pre-bond Testing of the Silicon Interposer
- Author
-
Krishnendu Chakrabarty and Ran Wang
- Subjects
business.product_category ,Yield (engineering) ,Materials science ,Bond testing ,Stacking ,Interposer ,Die (manufacturing) ,Composite material ,business ,Test path ,Silicon interposer - Abstract
In order to minimize the yield loss results from the stacking of good dies on a defective interposer, it is necessary to test the interposer before die stacking.
- Published
- 2017
- Full Text
- View/download PDF
29. Bonding of universal adhesives to dentine--Old wine in new bottles?
- Author
-
Liqun Zhou, Kai Jiao, Chen Chen, Li Na Niu, David H. Pashley, Haifeng Xie, Zheng yi Zhang, Franklin Chi Meng Tay, and Ji-hua Chen
- Subjects
Materials science ,Bond testing ,Scanning electron microscope ,Surface Properties ,Dentistry ,Composite Resins ,Dental Materials ,Random Allocation ,stomatognathic system ,Acid Etching, Dental ,Polymethacrylic Acids ,Adhesives ,Tensile Strength ,Materials Testing ,Humans ,Bisphenol A-Glycidyl Methacrylate ,Composite material ,Dental Enamel ,General Dentistry ,Tooth Demineralization ,Enamel paint ,business.industry ,Dental Bonding ,Resin Cements ,visual_art ,Dentin-Bonding Agents ,Dentin ,visual_art.visual_art_medium ,Methacrylates ,Adhesive ,business - Abstract
Objective Multi-mode universal adhesives offer clinicians the choice of using the etch-and-rinse technique, selective enamel etch technique or self-etch technique to bond to tooth substrates. The present study examined the short-term in vitro performance of five universal adhesives bonded to human coronal dentine. Methods Two hundred non-carious human third molars were assigned to five groups based on the type of the universal adhesives (Prime&Bond Elect, Scotchbond Universal, All-Bond Universal, Clearfil Universal Bond and Futurabond U). Two bonding modes (etch-and-rinse and self-etch) were employed for each adhesive group. Bonded specimens were stored in deionized water for 24 h or underwent a 10,000-cycle thermocycling ageing process prior to testing (N = 10). Microtensile bond testing (μTBS), transmission electron microscopy (TEM) of resin–dentine interfaces in non-thermocycled specimens and scanning electron microscopy (SEM) of tracer-infused water-rich zones within hybrid layers of thermocycled specimens were performed. Results Both adhesive type and testing condition (with/without thermocycling) have significant influences on μTBS. The use of each adhesive in either the etch-and-rinse or self-etch application mode did not result in significantly different μTBS to dentine. Hybrid layers created by these adhesives in the etch-and-rinse bonding mode and self-etch bonding mode were ∼5 μm and ≤0.5 μm thick respectively. Tracer-infused regions could be identified within the resin–dentine interface from all the specimens prepared. Conclusion The increase in versatility of universal adhesives is not accompanied by technological advances for overcoming the challenges associated with previous generations of adhesives. Therapeutic adhesives with bio-protective and bio-promoting effects are still lacking in commercialized adhesives. Clinical significance Universal adhesives represent manufacturers’ attempt to introduce versatility in product design via adaptation of a single-bottle self-etch adhesive for other application modes without compromising its bonding effectiveness.
- Published
- 2015
30. Correlation between surface crack width and steel corrosion in reinforced concrete
- Author
-
Michele Win Tai Mak, Pieter Desnerck, and Janet M. Lees
- Subjects
Bond testing ,0211 other engineering and technologies ,Reinforcement corrosion ,02 engineering and technology ,Reinforced concrete ,Steel bar ,Corrosion ,Cathodic protection ,Cracking ,lcsh:TA1-2040 ,021105 building & construction ,4005 Civil Engineering ,021108 energy ,Composite material ,lcsh:Engineering (General). Civil engineering (General) ,Reinforcement ,40 Engineering - Abstract
Reinforced concrete structures are subjected to weather conditions, chemical attack and other sources of deterioration that can affect their performance. In particular, corrosion of the internal steel reinforcement is considered to be one of the main causes of structural deterioration. A possible consequence of corrosion is cracking of the surrounding concrete. Visual inspections are often used to inform asset management strategies. Finding a relationship between cracks that are visible on the outer surface of a structure and corrosion of the internal reinforcement can be helpful when making assessment decisions. To this end, unconfined cylindrical concrete specimens with an embedded steel bar have been subjected to accelerated corrosion using an impressed current density of 200µA/cm2, leading to steel mass losses between 5-24%. This paper discusses the measured correlation between corrosion-induced surface crack widths and degree of reinforcement corrosion. The tests highlighted some limitations of a set-up that is commonly adopted for accelerated corrosion and concentric pull-out bond testing. The findings of this study represent a first step towards the standardisation of accelerated corrosion testing procedures using an impressed current.
- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.