Renaud, Jennifer M., Trottier, Mikaël, Mylonas, Ilias, Guimond, Jean, McArdle, Brian, Pibarot, Philippe, Dowsley, Taylor, Yip, Kathy, Turcotte, Éric, Maguire, Conor, Lalonde, Lucille, Gulenchyn, Karen, Wisenberg, Gerald, Wells, R. Glenn, Ruddy, Terrence, Chow, Benjamin, Beanlands, Robert S. B., deKemp, Robert A., Renaud, Jennifer M., Trottier, Mikaël, Mylonas, Ilias, Guimond, Jean, McArdle, Brian, Pibarot, Philippe, Dowsley, Taylor, Yip, Kathy, Turcotte, Éric, Maguire, Conor, Lalonde, Lucille, Gulenchyn, Karen, Wisenberg, Gerald, Wells, R. Glenn, Ruddy, Terrence, Chow, Benjamin, Beanlands, Robert S. B., and deKemp, Robert A.
Rubidium-ARMI (82Rb as an Alternative Radiopharmaceutical for Myocardial Imaging) is a multicenter trial to evaluate the accuracy, outcomes, and cost-effectiveness of low-dose 82Rb perfusion imaging using 3-dimensional (3D) PET/CT technology. Standardized imaging protocols are essential to ensure consistent interpretation. Methods: Cardiac phantom qualifying scans were obtained at 7 recruiting centers. Low-dose (10 MBq/kg) rest and pharmacologic stress 82Rb PET scans were obtained in 25 patients at each site. Summed stress scores, summed rest scores, and summed difference scores (SSS, SRS, and SDS [respectively] = SSS–SRS) were evaluated using 17-segment visual interpretation with a discretized color map. All scans were coread at the core lab (University of Ottawa Heart Institute) to assess agreement of scoring, clinical diagnosis, and image quality. Scoring differences greater than 3 underwent a third review to improve consensus. Scoring agreement was evaluated with intraclass correlation coefficient (ICC-r), concordance of clinical interpretation, and image quality using K coefficient and percentage agreement. Patient 99mTc and 201Tl SPECT scans (n = 25) from 2 centers were analyzed similarly for comparison to 82Rb. Results: Qualifying scores of SSS = 2, SDS = 2, were achieved uniformly at all imaging sites on 9 different 3D PET/CT scanners. Patient scores showed good agreement between core and recruiting sites: ICC-r = 0.92, 0.77 for SSS, SDS. Eighty-five and eighty-seven percent of SSS and SDS scores, respectively, had site–core differences of 3 or less. After consensus review, scoring agreement improved to ICC-r = 0.97, 0.96 for SSS, SDS (P < 0.05). The agreement of normal versus abnormal (SSS = 4) and nonischemic versus ischemic (SDS = 2) studies was excellent: ICC-r = 0.90 and 0.88. Overall interpretation showed excellent agreement, with a K = 0.94. Image quality was perceived differently by the site versus core reviewers (90% vs. 76% good or better; P < 0.05