7 results on '"Kesteris U"'
Search Results
2. Similar migration for medial congruent and cruciate-retaining tibial components in an anatomic TKA system: a randomized controlled trial of 60 patients followed with RSA for 2 years.
- Author
-
Christensson A, Tveit M, Kesteris U, and Flivik G
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Patient Reported Outcome Measures, Radiostereometric Analysis, Arthroplasty, Replacement, Knee instrumentation, Foreign-Body Migration, Knee Prosthesis, Prosthesis Design
- Abstract
Background and purpose - There is an ongoing debate regarding the appropriate level of constraint in primary TKA. To provide increased stability and better kinematics, more resembling a natural knee, a medial congruent (MC) tibial insert has been introduced. To investigate potential impact on implant migration, we evaluated the cemented Persona TKA, randomizing between MC and cruciate-retaining (CR) tibial designs. Patients and methods - 60 patients with primary osteoarthritis were randomized to either the CR or MC tibial component. Radiostereometric analysis (RSA) examinations, evaluating translational and rotational migration as well as maximal total point motion (MTPM), were performed on the first postoperative day, at 3 months, and 1 and 2 years after surgery. Preoperative, and 1- and 2-year patientreported outcome measures (PROMs) data (KOOS and FJS) were collected. Results - The mean tibial MTPM at 3 months were 0.48 mm (95% CI 0.37-0.58) and 0.56 mm (0.45-0.67) for the CR and MC respectively. 2 years postoperatively the respective values were 0.62 mm (0.50-0.73) and 0.73 mm (0.49-0.96). There was no statistically significant difference in migration between groups, for either the femoral or the tibial component, regarding x-, y-, and z-translations or rotations. Both CR and MC groups improved as expected in PROM scores pre- to postoperatively, but without a statistically significant difference between groups. There were no revisions or other serious adverse events related to surgery. Interpretation - The results are promising, indicating good fixation for both designs, and this is in line with other well-performing TKAs on the market. The increased medial congruity of the MC inlay does not seem to affect the migration or the PROMs up to 2 years.
- Published
- 2022
- Full Text
- View/download PDF
3. No effect of femoral canal jet-lavage on the stability of cementless stems in primary hip arthroplasty: a randomised RSA study with 6 years follow-up.
- Author
-
Zampelis V, Flivik G, and Kesteris U
- Subjects
- Adult, Aged, Arthroplasty, Replacement, Hip adverse effects, Arthroplasty, Replacement, Hip instrumentation, Female, Femur surgery, Follow-Up Studies, Humans, Male, Middle Aged, Prosthesis Design, Radiostereometric Analysis, Time Factors, Titanium, Treatment Outcome, Arthroplasty, Replacement, Hip methods, Hip Prosthesis, Osteoarthritis, Hip surgery, Therapeutic Irrigation methods
- Abstract
Introduction: In contrast to cemented hip prostheses, the effect of washing the bone bed with jet-lavage prior to insertion of cementless stem components in primary hip arthroplasty (THA) is unclear. Jet-lavage potentially decreases the risk of fat embolisation during rasping and stem insertion and might help in avoiding bacterial contamination. An earlier animal study has shown less debris and better-organised trabecular structure of new bone when jet-lavage was used. We hypothesised that the primary stability of cementless femoral stems implanted after jet-lavage of the femoral canal prior to stem insertion would improve with earlier stabilisation, as measured with Radiostereometry (RSA), compared with insertion without prior jet-lavage., Methods: 40 patients with primary osteoarthritis operated on with a cementless titanium grit blasted stem are included in the study. The patients were randomised to either jet-lavage or control without any lavage of the femoral canal prior to insertion of the prosthesis. The stem migration pattern was measured with RSA at 0, 3, 12, 24 and 72 months., Results: At 6 years, 19 patients remained for analysis in the jet-lavage and 18 in the control group. We found no difference in extent or pattern of migration as measured with RSA. Both groups seemed to have stabilised within 3 months after a slight subsidence and retroversion. No stem was revised or considered loose as measured with RSA., Conclusions: Washing the bone bed with jet-lavage prior to insertion of cementless stems does not affect the stability of cementless femoral components. No adverse effects were observed.
- Published
- 2020
- Full Text
- View/download PDF
4. Locally administered bisphosphonate in hip stem revisions using the bone impaction grafting technique: a randomised, placebo-controlled study with DXA and five-year RSA follow-up.
- Author
-
Belfrage O, Tägil M, Sundberg M, Kesteris U, and Flivik G
- Subjects
- Absorptiometry, Photon, Aged, Aged, 80 and over, Bone Density, Double-Blind Method, Female, Femur surgery, Follow-Up Studies, Humans, Male, Middle Aged, Prosthesis Failure, Radiostereometric Analysis, Transplantation, Homologous, Arthroplasty, Replacement, Hip methods, Bone Density Conservation Agents administration & dosage, Bone Transplantation methods, Diphosphonates administration & dosage, Hip Prosthesis, Reoperation methods
- Abstract
Background:: Bisphosphonates have previously been shown to increase the density of impacted graft bone. In the present study we hypothesise that bisphosphonates also reduce early stem subsidence. We examined the effect of locally applied bisphosphonate to allografts on prosthetic micromotion and bone density in femoral stem revision with impaction grafting., Methods:: 37 patients were randomised to either clodronate or saline as local adjunct to the morsellised allograft bone. 24 patients were finally analysed per protocol and evaluated by dual-energy x-ray absorptiometry (DXA) during the first year and with radiostereometric analysis (RSA) for 5 years., Results:: There were no significant differences neither in bone density, nor in migratory behaviour between the groups. The femoral stems had subsided 3.6 mm in both groups (p = 0.99) at 5 years and there was no difference as measured over time with mixed models analysis. The clinical outcome was good in both groups., Conclusion:: Clodronate as a local addendum to allograft bone in hip revision did not increase bone density or reduce micromotion of the implant.
- Published
- 2019
- Full Text
- View/download PDF
5. Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?
- Author
-
Weber E, Olsson C, Kesteris U, and Flivik G
- Subjects
- Aged, Aged, 80 and over, Arthroplasty, Replacement, Hip, Female, Humans, Male, Middle Aged, Prosthesis Design, Prosthesis Failure, Range of Motion, Articular, Hip Prosthesis
- Abstract
Background and purpose - A tapered, polished and collarless stem is normally equipped with a hollow centralizer to prevent the stem from becoming end-bearing in the cement as the stem subsides. In a randomized clinical trial, we evaluated such a stem (MS-30), which was initially introduced with a solid centralizer but was later recommended to be fitted with a hollow centralizer. We hypothesized that while the stem would sink more, it would become rotationally stable and have less retroversion with a hollow centralizer than with a solid centralizer. Patients and methods - We randomized 60 patients with primary hip arthritis to receive either a hollow centralizer or a solid centralizer with the stem. The effect was evaluated over a 10-year follow-up period with repeated RSA examinations, conventional radiographs, and clinical follow-ups using the WOMAC and SF-12 questionnaires. Results - At 10-year follow-up, the group with hollow centralizers had subsided more than the group with solid centralizers (1.99 mm (hollow) as opposed to 0.57 mm (solid); p < 0.001). However, rotation was similar at 10-year follow-up (mean retroversion 1.34° (hollow) and 1.30° (solid)). Both groups showed excellent 10-year results, with similar clinical outcome, and none of the stems were radiographically loose or had been revised. Interpretation - As expected, there was more subsidence in the group with hollow centralizers, and with similar magnitude to that reported in earlier RSA studies on conceptually similar prostheses. Interestingly, there was no difference in the rotational behavior of the prostheses. This stem type appears to have a design that, regardless of the type of centralizer and the possibility of subsidence, withstands the rotational forces it is subjected to very well. This study does not support the need for a hollow centralizer for these types of stems.
- Published
- 2017
- Full Text
- View/download PDF
6. Stable migration pattern of an ultra-short anatomical uncemented hip stem: a prospective study with 2 years radiostereometric analysis follow-up.
- Author
-
Mahmoud AN, Kesteris U, and Flivik G
- Subjects
- Adolescent, Adult, Aged, Arthroplasty, Replacement, Hip methods, Femur diagnostic imaging, Follow-Up Studies, Hip Joint diagnostic imaging, Humans, Middle Aged, Osteoarthritis, Hip diagnosis, Prospective Studies, Prosthesis Design, Treatment Outcome, Young Adult, Femur surgery, Hip Joint surgery, Hip Prosthesis, Osteoarthritis, Hip surgery, Radiostereometric Analysis methods
- Abstract
Introduction: Shorter, anatomically shaped and proximally loading stems have been developed to achieve better stress distribution and be more bone preserving. The purpose of this prospective study was to evaluate the migration pattern of the Proxima™ ultra-short uncemented stem using radiostereometric analysis (RSA), and to review the literature regarding the migration of short stemmed hip arthroplasty., Methods: 25 patients (28 hips) with hip osteoarthritis received a Proxima stem during total hip arthroplasty (THA). To measure stem migration, repeated RSA examinations were done during a 2 year follow up period. The patients were evaluated with the hip specific (HOOS) and the generic health (EQ5D) scores up to 1 year, and clinically for 6 years postoperatively., Results: Almost all migration occurred within the first 3 months, with mean subsidence of 0.22 mm and varus rotation of 1.04°, being the primary effect variables. After the third postoperative month and up to the 2 year RSA follow up no further significant migration occurred. The outcome scores showed substantial improvement after 1 year. No revisions were performed or indicated for any stem after a mean clinical follow up of 72.1 months., Conclusions: Like many other uncemented stems, the Proxima showed early migration up to 3 months hereafter osseointegration seems to have occurred. The achieved stability and clinical outcomes indicate favorable early results for this stem in younger patients who have good bone quality and average BMI. We found, however, the surgical technique to be slightly more demanding compared to conventional stems owing to the unique implant design that necessitates specific adjusted femoral cutting and broaching procedures.
- Published
- 2017
- Full Text
- View/download PDF
7. A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients.
- Author
-
Olivecrona H, Maguire GQ Jr, Noz ME, Zeleznik MP, Kesteris U, and Weidenhielm L
- Subjects
- Algorithms, Arthroplasty, Replacement, Hip adverse effects, Humans, Image Processing, Computer-Assisted methods, Long-Term Care methods, Longitudinal Studies, Models, Anatomic, Prosthesis Failure, Radiation Dosage, Radiostereometric Analysis, Reproducibility of Results, Tantalum, Tomography, X-Ray Computed methods, Arthroplasty, Replacement, Hip methods, Hip Prosthesis
- Abstract
Background: Radiostereometric analysis (RSA) is often used for evaluating implanted devices over time. Following patients who have had tantalum beads implanted as markers in conjunction with joint replacements is important for longitudinal evaluation of these patients and for those with similar implants. As doing traditional RSA imaging is exacting and limited to specialized centers, it is important to consider alternative techniques for this ongoing evaluation. This paper studies the use of computed tomography (CT) to evaluate over time tantalum beads which have been implanted as markers., Methods: The project uses both a hip model implanted with tantalum beads, acquired in several orientations, at two different CT energy levels, and a cohort of seven patients. The model was evaluated twice by the same observer with a 1-week interval. All CT volumes were analyzed using a semi-automated 3D volume fusion (spatial registration) tool which provides landmark-based fusion of two volumes, registering a target volume with a reference volume using a rigid body 3D algorithm. The mean registration errors as well as the accuracy and repeatability of the method were evaluated., Results: The mean registration error, maximum value of repeatability, and accuracy for the relative movement in the model were 0.16 mm, 0.02° and 0.1 mm, and 0.36° and 0.13 mm for 120 kVp and 0.21 mm, 0.04° and 0.01 mm, and 0.39° and 0.12 mm for 100 kVp. For the patients, the mean registration errors per patient ranged from 0.08 to 0.35 mm. These results are comparable to those in typical clinical RSA trials. This technique successfully evaluated two patients who would have been lost from the cohort if only RSA were used., Conclusions: The proposed technique can be used to evaluate patients with tantalum beads over time without the need for stereoradiographs. Further, the effective dose associated with CT is decreasing.
- Published
- 2016
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.