1. Energy Analysis of Precooling Air Compressor System.
- Author
-
Hu, Yu, Xu, Weiqing, Jia, Guanwei, Li, Guangyao, and Cai, Maolin
- Subjects
AIR compressors ,AIR analysis ,INDUSTRIAL energy consumption ,COMPRESSORS ,CARBON emissions ,ENERGY consumption - Abstract
Energy saving is one of the main technique routes for net zero carbon emissions. Air compressor systems take up a large part of energy consumption in the industrial field. A pre-cooling air compressor system was proposed for energy saving by cooling the air before it flows in a compressor. The energy efficiency of the proposed system was analyzed. As additional energy consumption is required for air cooling, the feasibility of the pre-cooling method for energy saving was analyzed. As the efficiency of the pre-cooling air compressor system is mainly influenced by the environment temperature and humidity, applicability of the system in different regions and at different seasons was discussed. A pilot project was performed to verify the technical feasibility and economics of the proposed system. When the precooling temperature of the pilot system was set to 2 °C, the annual pneumatic-electrical ratio of the system can be increased by approximately 2% in several regions of China. This paper shows the pre-cooling air compressor system is feasible for energy saving. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF