1. MEET CURRENT HARMONIC LIMITS - CHALLENGES AND SOLUTIONS.
- Author
-
Vuksic, Marko and Batarelo, Sandra
- Subjects
ELECTRIC power factor ,CAPACITORS ,ELECTRIC inductors ,DIRECT currents ,ELECTRIC resonators - Abstract
Distortion of mains current caused by non-linear loads creates harmonics that can significantly affect the overall system efficiency and particularly power factor. This paper explores several methods of higher harmonics mitigation according to the limits specified in standards IEC 610000-3-2 and IEC 5555-2 and in the equivalent European standard EN 61000-3-2. [4]. Passive power factor correction approach improves the power factor by filtering harmonics using passive filters comprising of inductors and capacitors on both AC and DC sides of the power supply. Active power factor correction includes use of Power Factor Correction circuit or use of dedicated circuits for injection of 3rd and 5th harmonic. Regarding the above-mentioned correction of the power factor, in this paper the emphasis will be given on the interleaved boost regulator usage for mitigation of the load current higher harmonics. Future work will include resonant converters for power factor correction purposes. [ABSTRACT FROM AUTHOR]
- Published
- 2024