9 results on '"Cappabianca, G"'
Search Results
2. SURVIVAL AND RECURRENCE OF ENDOCARDITIS FOLLOWING MECHANICAL VS. BIOLOGICAL MITRAL VALVE REPLACEMENT FOR ENDOCARDITIS IN PATIENTS AGED 40 TO 70 YEARS: DATA FROM THE INFECT-REGISTRY
- Author
-
Salsano, A., Di Mauro, M., Labate, L., Della Corte, A., De Bonis, M., Rinaldi, M., Actis Dato, G., Nicolini, F., De Vincentiis, C., Cappabianca, G., Cugola, D., Pacini, D., Vendramin, I., Pilozzi Casado, A., Mikus, E., Onorati, F., Scrofani, R., Musumeci, F., Colli, A., Nicolardi, S., Vizzardi, E., Pantaleo, A., Villa, E., Pollari, F., Barili, F., Parolari, A., Lorusso, R., and Santini, F.
- Published
- 2024
- Full Text
- View/download PDF
3. Platelet Reduction after Transcatheter Aortic Valve Implantation: Results from the PORTRAIT Study.
- Author
-
Jiritano F, Di Mauro M, Serraino GF, Mastroroberto P, Caporali E, Ferrari E, Kowalewski M, Scrofani R, Patanè L, Visicchio G, Paparella D, Falcetta G, Colli A, Matteucci M, Cappabianca G, Pollari F, Fischlein T, and Lorusso R
- Abstract
Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/µL. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary.
- Published
- 2024
- Full Text
- View/download PDF
4. [Single-center retrospective observational study on predictors of residual mitral regurgitation 1 year after MitraClip® implantation].
- Author
-
Costantino MF, Stolfi L, D'Addeo G, Cappabianca G, Cortese F, Fiorilli R, Biscione C, Matera A, Tarsia G, Lopizzo A, Mannarini A, Stabile E, and Luzi G
- Subjects
- Humans, Retrospective Studies, Echocardiography, Patient Readmission, Mitral Valve Insufficiency surgery
- Abstract
Background: The extent of residual mitral regurgitation (MR) (1+ vs ≥2+) has a notable impact on the outcome of MitraClip (MC) repair of significant functional MR. In this retrospective single-center study, we evaluated the predictors of MI ≥2+ at 1 year in one of our case series., Methods: Overall, 58 patients with moderate severe functional MR underwent MC implantation; of these, 48 patients had instrumental clinical follow-up for 1 year., Results: At 1 year, 10 patients died (mortality 17.2%). In the remaining 48 patients, the incidence of rehospitalization was 8.3%, and the incidence of MR grade 1+ and ≥2+ was 54.1% (n = 26) and 45.9% (n = 22), respectively. In patients with MR ≥2+, clinical and instrumental outcomes were worse than in patients with MR 1+. The height of the posterior leaflet and the extent of immediate postprocedural MR were independent predictors of MR ≥2+., Conclusions: Percutaneous repair with MC of moderate/severe functional MR has favorable 1-year outcomes in terms of mortality and rehospitalizations. The best results are achieved in patients with residual MR 1+. Echocardiographic parameters are independent predictors of residual MR ≥2+.
- Published
- 2024
- Full Text
- View/download PDF
5. Surgical repair of left ventricular free-wall rupture complicating acute myocardial infarction: a single-center 30 years of experience.
- Author
-
Matteucci M, Ferrarese S, Mantovani V, Corazzari C, Cappabianca G, Messina C, Garis S, Severgnini P, Lorusso R, and Musazzi A
- Abstract
Background: Left ventricular free-wall rupture (LVFWR) is a catastrophic complication of acute myocardial infarction (AMI). Historically, cardiac surgery is considered the treatment of choice. However, because of the rarity of this entity, little is known regarding the efficacy and safety of surgical treatment for post-infarction LVFWR. The aim of this study was to report a single-center experience in this field over a period of 30 years., Methods: Patients who developed LVFWR following AMI and underwent surgical repair at our Institution from January 1990 to December 2019 were considered. The primary end-point was in-hospital morality rate; secondary outcomes were long-term survival and postoperative complications. Multivariate analysis was carried out by constructing a logistic regression model to identify risk factors for early mortality., Results: A total of 35 patients were enrolled in this study. The mean age was 68.9 years; 65.7% were male. The oozing type of LVFWR was encountered in 29 individuals, and the blowout type in 6 subjects. Sutured repair was used in 77.1% of patients, and sutureless repair in the remaining cases. The in-hospital mortality rate was 28.6%. Low cardiac output syndrome was the main cause of postoperative death. Multivariable analysis identified age >75 years at operation, preoperative cardiac arrest, concurrent ventricular septal rupture (VSR) as independent predictors of in-hospital death. Follow-up was complete in 100% of patients who survived surgery (mean follow-up: 9.3 ± 7.8 years); among the survivors, 16 patients died during the follow-up with a 3-year and 12-year overall survival rate of 82.5% and 55.2%, respectively., Conclusions: Surgical treatment of LVFWR following AMI is possible with acceptable in-hospital mortality and excellent long-term results. Advanced age, concurrent VSR and cardiac arrest at presentation are independent risk factors of poor early outcome., Competing Interests: RL reported being the principal investigator of the Perceval Sutureless Implant versus Standard Aortic Valve Replacement (PERSIST-AVR) Study, sponsored by LivaNova, and consulting for Medtronic, LivaNova, Abiomed, and Eurosets with all honoraria paid to the University. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The reviewer FJ declared a past co-authorship with the author RL to the handling editor. The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision., (© 2024 Matteucci, Ferrarese, Mantovani, Corazzari, Cappabianca, Messina, Garis, Severgnini, Lorusso and Musazzi.)
- Published
- 2024
- Full Text
- View/download PDF
6. Survival and Recurrence of Endocarditis following Mechanical vs. Biological Aortic Valve Replacement for Endocarditis in Patients Aged 40 to 65 Years: Data from the INFECT-Registry.
- Author
-
Salsano A, Di Mauro M, Labate L, Della Corte A, Lo Presti F, De Bonis M, Trumello C, Rinaldi M, Cura Stura E, Actis Dato G, Punta G, Nicolini F, Carino D, De Vincentiis C, Garatti A, Cappabianca G, Musazzi A, Cugola D, Merlo M, Pacini D, Folesani G, Sponga S, Vendramin I, Pilozzi Casado A, Rosato F, Mikus E, Savini C, Onorati F, Luciani GB, Scrofani R, Epifani F, Musumeci F, Lio A, Colli A, Falcetta G, Nicolardi S, Zaccaria S, Vizzardi E, Pantaleo A, Minniti G, Villa E, Dalla Tomba M, Pollari F, Barili F, Parolari A, Lorusso R, and Santini F
- Abstract
Background: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years., Methods: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test., Results: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period ( p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039)., Conclusions: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.
- Published
- 2023
- Full Text
- View/download PDF
7. Platelet Reduction after Aortic Bioprosthesis Implantation: Results from the PORTRAIT Study.
- Author
-
Jiritano F, Serraino GF, Di Mauro M, Borelli M, Scrofani R, Patanè L, Caporali E, Matteucci M, Fina D, Kowalewski M, Pollari F, Fischlein T, Visicchio G, Paparella D, Falcetta G, Colli A, Mastroroberto P, Cappabianca G, and Lorusso R
- Abstract
Background : Platelet count reduction (PR) is a common but unclear phenomenon that occurs after aortic bioprosthesis valve implantation (bio-AVR). This study aimed to investigate the occurrence and clinical impact of PR in patients receiving stented, rapid deployment (RDV), or stentless bioprostheses. Methods : 1233 adult bio-AVR patients were enrolled. Platelet count variation, early post-operative adverse events, and in-hospital mortality were analysed. Results : 944 patients received a stented valve, an RDV was implanted in 218 patients, and 71 patients had a stentless bioprosthesis. In all groups, the platelet count at discharge was lower than the baseline values ( p < 0.001). The percentage of PR was 27% in the stented group, 56% in the RDV group, and 55% in the stentless group. A higher platelet reduction, reaching the minimum platelet value, was observed in the RDV (mean: -30.84, standard error (SE): 5.91, p < 0.001) and stentless (mean: 22.54, SE: 9.10, p = 0.03) groups compared to the stented group. A greater PR occurred as the size of the bioprosthesis increased in RDV ( p = 0.01), while platelet count variation was not directly proportional to the stented bioprosthesis size ( p < 0.001). PR was not affected by cardiopulmonary bypass (mean: -0.00, SE: 0.001, p = 0.635) or cross-clamp (mean: -0.00, SE: 0.002, p = 0.051) times in any of the groups. RDV subjects experienced more in-hospital adverse events. PR was found to be associated with ischemic strokes in the overall population. Conclusions : Bio-AVR is associated with significant but transient PR. RDV patients more likely experience significant PR and related adverse clinical events. PR is associated with ischemic strokes, regardless of the bioprosthesis type., Competing Interests: R.L.: consultant for Medtronic and LivaNova, and Member of the Medical Advisory Board of Eurosets and PulseCath (all honoraria are paid to the University); T.F.: consultant LivaNova and BioStable. The other authors declare no conflict of interests.
- Published
- 2023
- Full Text
- View/download PDF
8. Similar outcome of tricuspid valve repair and replacement for isolated tricuspid infective endocarditis.
- Author
-
Di Mauro M, Bonalumi G, Giambuzzi I, Dato GMA, Centofanti P, Corte AD, Ratta ED, Cugola D, Merlo M, Santini F, Salsano A, Rinaldi M, Mancuso S, Cappabianca G, Beghi C, De Vincentiis C, Biondi A, Livi U, Sponga S, Pacini D, Murana G, Scrofani R, Antona C, Cagnoni G, Nicolini F, Benassi F, De Bonis M, Pozzoli A, Pano M, Nicolardi S, Falcetta G, Colli A, Musumeci F, Gherli R, Vizzardi E, Salvador L, Picichè M, Paparella D, Margari V, Troise G, Villa E, Dossena Y, Lucarelli C, Onorati F, Faggian G, Mariscalco G, Maselli D, Barili F, Parolari A, and Lorusso R
- Subjects
- Humans, Treatment Outcome, Tricuspid Valve diagnostic imaging, Tricuspid Valve surgery, Cardiac Surgical Procedures adverse effects, Endocarditis surgery, Endocarditis, Bacterial surgery
- Abstract
Aims: To compare early and late mortality of acute isolated tricuspid valve infective endocarditis (TVIE) treated with valve repair or replacement., Methods: Patients who were surgically treated for TVIE from 1983 to 2018 were retrieved from the Italian Registry for Surgical Treatment of Valve and Prosthesis Infective Endocarditis. All the patients were followed up by means of phone interview or calling patient referral physicians or cardiologists. Kaplan-Meier method was used to assess late survival and survival free from TVIE recurrence with log-rank test for univariate comparison. The primary end points were early mortality (30 days after surgery) and long-term survival free from TVIE recurrence., Results: A total of 4084 patients were included in the registry. Among them, 149 patients were included in the study. Overall, 77 (51.7%) underwent TV repair and 72 (48.3%) TV replacement. Early mortality was 9% (13 patients). Expected early mortality according to EndoSCORE was 12%. The TV repair showed lower mortality and major complication rate (7% and 16%), compared with TV replacement (11% and 25%), but statistical significance was not reached. Median follow-up was 19.1 years (14.3-23.8). Late deaths were 30 and IE recurrences were 5. No difference in cardiac survival free from IE was found between the two groups after 20 years (80 ± 6% Repair Group vs 59 ± 13% Replacement Group, P = 0.3)., Conclusions: Overall results indicate that once surgically addressed, TVIE has a low recurrence rate and excellent survival, apparently regardless of the type of surgery used to treat it., (Copyright © 2022 Italian Federation of Cardiology - I.F.C. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
9. Early paravalvular leak after conventional mitral valve replacement: A single-center analysis.
- Author
-
Matteucci M, Ferrarese S, Cantore C, Mantovani V, Pedroni G, Cappabianca G, Corazzari C, Kowalewski M, Severgnini P, Lorusso R, and Beghi C
- Subjects
- Follow-Up Studies, Humans, Mitral Valve surgery, Retrospective Studies, Time Factors, Treatment Outcome, Endocarditis surgery, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation methods, Mitral Valve Insufficiency surgery
- Abstract
Introduction: Paravalvular leak (PVL) is a well-recognized complication after mitral valve replacement (MVR). However, there are only a few studies analyzing leak occurrence and postoperative results after surgical MVR. The aim of this study was to assess the rate and determinants of early mitral PVL and to evaluate the impact on survival., Methods: We performed a retrospective analysis involving patients who underwent MVR from January 2012 to December 2019 at our Institution. Postoperative transthoracic echocardiography evaluation was done for all subjects before hospital discharge. Multivariable analysis was carried out by constructing a logistic regression model to identify predictors for PVL occurrence., Results: Four hundred ninety-four patients were enrolled. Operative mortality was 4.9%. Early mitral PVL was found in 16 patients (3.2%); the majority were mild (75%). Leaks occurred more frequently along the posterior segment of the mitral valve annulus (62.5%). Only one individual with moderate-to-severe PVL underwent reoperation during the same hospital admission. Multivariable analysis revealed that preoperative diagnosis of infective endocarditis was the only factor associated with early leak after MVR (odds ratio: 4.96; 95% confidence interval: 1.45-16.99; p = .011). Overall mortality at follow-up (mean follow-up time: 4.7 [SD: 2.5] years) was 19.6% and favored patients without early mitral PVL., Conclusion: The incidence of early PVL after MVR is low. PVL is usually mild and develop more frequently along the posterior segment of the mitral valve annulus. Preoperative diagnosis of infective endocarditis increases the risk of PVL formation., (© 2022 The Authors. Journal of Cardiac Surgery published by Wiley Periodicals LLC.)
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.