2. Enhanced Technique for Accurate Localization and Life-Sign Detection of Human Subjects Using Beam-Steering Radar Architectures.
- Author
-
Mercuri M, Sacco G, Hornung R, Visser H, Lorato I, Pisa S, Veltri P, and Dolmans G
- Abstract
In this work, we propose a signal processing technique for beam-steering radar architectures allowing concurrent two-dimensional (2-D) localization and vital signs monitoring of human subjects. We demonstrated it by using a single-input single-output (SISO) frequencymodulated continuous wave (FMCW) radar which integrates two frequency-scanning antennas (FSAs). This method is capable of isolating the Doppler signal generated by each single subject from the contributions of all the reflections in the monitored environment. This allows determining the number of individuals in the room and accurately measuring their vital signs parameters (respiration and heart rates) and 2-D positions (range and azimuth information). The spectral analysis, the data matrix generation and the signal processing technique are detailed and discussed. Experimental results demonstrated the feasibility of the proposed approach, showing the ability in determining the number of subjects present in the room, in accurately measuring and tracking over time their vital signs parameters, and in 2-D localization with errors within the limits of the radar range and angular resolutions. Practical applications arise for healthcare, Hospital 4.0, Internet of Medical Things (IoMT), ambient assisted living, smart buildings and through-wall sensing.
- Published
- 2024
- Full Text
- View/download PDF
3. The Utility of a Novel Electrocardiogram Patch Using Dry Electrodes Technology for Arrhythmia Detection During Exercise and Prolonged Monitoring: Proof-of-Concept Study.
- Author
-
Fruytier LA, Janssen DM, Campero Jurado I, van de Sande DA, Lorato I, Stuart S, Panditha P, de Kok M, and Kemps HM
- Abstract
Background: Accurate detection of myocardial ischemia and arrhythmias during free-living exercise could play a pivotal role in screening and monitoring for the prevention of exercise-related cardiovascular events in high-risk populations. Although remote electrocardiogram (ECG) solutions are emerging rapidly, existing technology is neither designed nor validated for continuous use during vigorous exercise., Objective: In this proof-of-concept study, we evaluated the usability, signal quality, and accuracy for arrhythmia detection of a single-lead ECG patch platform featuring self-adhesive dry electrode technology in individuals with chronic coronary syndrome. This sensor was evaluated during exercise and for prolonged, continuous monitoring., Methods: We recruited a total of 6 consecutive patients with chronic coronary syndrome scheduled for an exercise stress test (EST) as part of routine cardiac follow-up. Traditional 12-lead ECG recording was combined with monitoring with the ECG patch. Following the EST, the participants continuously wore the sensor for 5 days. Intraclass correlation coefficients (ICC) and Wilcoxon signed rank tests were used to assess the utility of detecting arrhythmias with the patch by comparing the evaluations of 2 blinded assessors. Signal quality during EST and prolonged monitoring was evaluated by using a signal quality indicator. Additionally, connection time was calculated for prolonged ECG monitoring. The comfort and usability of the patch were evaluated by a web-based self-assessment questionnaire., Results: A total of 6 male patients with chronic coronary syndrome (mean age 69.8, SD 6.2 years) completed the study protocol. The patch was worn for a mean of 118.3 (SD 5.6) hours. The level of agreement between the patch and 12-lead ECG was excellent for the detection of premature atrial contractions and premature ventricular contractions during the whole test (ICC=0.998, ICC=1.000). No significant differences in the total number of premature atrial contractions and premature ventricular contractions were detected neither during the entire exercise test (P=.79 and P=.18, respectively) nor during the exercise and recovery stages separately (P=.41, P=.66, P=.18, and P=.66). A total of 1 episode of atrial fibrillation was detected by both methods. Total connection time during recording was between 88% and 100% for all participants. There were no reports of skin irritation, erythema, or pain while wearing the patch., Conclusions: This proof-of-concept study showed that this innovative ECG patch based on self-adhesive dry electrode technology can potentially be used for arrhythmia detection during vigorous exercise. The results suggest that the wearable patch is also usable for prolonged continuous ECG monitoring in free-living conditions and can therefore be of potential use in cardiac rehabilitation and tele-monitoring for the prevention of exercise-related cardiovascular events. Future efforts will focus on optimizing signal quality over time and conducting a larger-scale validation study focusing on both arrhythmia and ischemia detection., (©Lonneke A Fruytier, Daan M Janssen, Israel Campero Jurado, Danny AJP van de Sande, Ilde Lorato, Shavini Stuart, Pradeep Panditha, Margreet de Kok, Hareld MC Kemps. Originally published in JMIR Formative Research (https://formative.jmir.org), 30.11.2023.)
- Published
- 2023
- Full Text
- View/download PDF
4. A SISO FMCW radar based on inherently frequency scanning antennas for 2-D indoor tracking of multiple subjects.
- Author
-
Sacco G, Mercuri M, Hornung R, Visser H, Lorato I, Pisa S, and Dolmans G
- Abstract
The contextual non-invasive monitoring and tracking of multiple human targets for health and surveillance purposes is an increasingly investigated application. Radars are good candidates, since they are able to remotely monitor people without raising privacy concerns. However, radar systems are typically based on complex architectures involving multiple channels and antennas, such as multiple-input and multiple-output (MIMO) or electronic beam scanning, resulting also in a high power consumption. In contrast with existing technologies, this paper proposes a single-input and single-output (SISO) frequency-modulated continuous wave (FMCW) radar in combination with frequency scanning antennas for tracking multiple subjects in indoor environments. A data processing method is also presented for angular separation and clutter removal. The system was successfully tested in five realistic indoor scenarios involving paired subjects, which were either static or moving along predefined paths varying their range and angular position. In all scenarios, the radar was able to track the targets, reporting a maximum mean absolute error (MAE) of 20 cm and 5.64[Formula: see text] in range and angle, respectively. Practical applications arise for ambient assisted living, telemedicine, smart building applications and surveillance., (© 2023. Springer Nature Limited.)
- Published
- 2023
- Full Text
- View/download PDF
5. Comparison between Speckle Plethysmography and Photoplethysmography during Cold Pressor Test Referenced to Finger Arterial Pressure.
- Author
-
Herranz Olazabal J, Lorato I, Kling J, Verhoeven M, Wieringa F, Van Hoof C, Verkruijsse W, and Hermeling E
- Subjects
- Humans, Fingers, Blood Pressure physiology, Hand, Photoplethysmography, Arterial Pressure
- Abstract
Speckle Plethysmography (SPG) and Photoplethysmography (PPG) are different biophotonics technologies that allow for measurement of haemodynamics. As the difference between SPG and PPG under low perfusion conditions is not fully understood, a Cold Pressor Test (CPT-60 s full hand immersion in ice water), was used to modulate blood pressure and peripheral circulation. A custom-built setup simultaneously derived SPG and PPG from the same video streams at two wavelengths (639 nm and 850 nm). SPG and PPG were measured at the right index finger location before and during the CPT using finger Arterial Pressure (fiAP) as a reference. The effect of the CPT on the Alternating Component amplitude (AC) and Signal-to-Noise Ratio (SNR) of dual-wavelength SPG and PPG signals was analysed across participants. Furthermore, waveform differences between SPG, PPG, and fiAP based on frequency harmonic ratios were analysed for each subject (n = 10). Both PPG and SPG at 850 nm show a significant reduction during the CPT in both AC and SNR. However, SPG showed significantly higher and more stable SNR than PPG in both study phases. Harmonic ratios were found substantially higher in SPG than PPG. Therefore, in low perfusion conditions, SPG seems to offer a more robust pulse wave monitoring with higher harmonic ratios than PPG.
- Published
- 2023
- Full Text
- View/download PDF
6. Signal Quality Analysis for Long-Term ECG Monitoring Using a Health Patch in Cardiac Patients.
- Author
-
Campero Jurado I, Lorato I, Morales J, Fruytier L, Stuart S, Panditha P, Janssen DM, Rossetti N, Uzunbajakava N, Serban IB, Rikken L, de Kok M, Vanschoren J, and Brombacher A
- Subjects
- Humans, Artifacts, Electrocardiography, Electrodes, Monitoring, Ambulatory, Atrial Fibrillation diagnosis
- Abstract
Cardiovascular diseases (CVD) represent a serious health problem worldwide, of which atrial fibrillation (AF) is one of the most common conditions. Early and timely diagnosis of CVD is essential for successful treatment. When implemented in the healthcare system this can ease the existing socio-economic burden on health institutions and government. Therefore, developing technologies and tools to diagnose CVD in a timely way and detect AF is an important research topic. ECG monitoring patches allowing ambulatory patient monitoring over several days represent a novel technology, while we witness a significant proliferation of ECG monitoring patches on the market and in the research labs, their performance over a long period of time is not fully characterized. This paper analyzes the signal quality of ECG signals obtained using a single-lead ECG patch featuring self-adhesive dry electrode technology collected from six cardiac patients for 5 days. In particular, we provide insights into signal quality degradation over time, while changes in the average ECG quality per day were present, these changes were not statistically significant. It was observed that the quality was higher during the nights, confirming the link with motion artifacts. These results can improve CVD diagnosis and AF detection in real-world scenarios.
- Published
- 2023
- Full Text
- View/download PDF
7. A Comparison of Video-based Methods for Neonatal Body Motion Detection.
- Author
-
Peng Z, van de Sande D, Lorato I, Long X, Liang RH, Andriessen P, Cottaar W, Stuijk S, and van Pul C
- Subjects
- Humans, Infant, Infant, Newborn, Monitoring, Physiologic methods, Motion, Vital Signs, Infant, Premature, Seizures diagnosis
- Abstract
Preterm infants in a neonatal intensive care unit (NICU) are continuously monitored for their vital signs, such as heart rate and oxygen saturation. Body motion patterns are documented intermittently by clinical observations. Changing motion patterns in preterm infants are associated with maturation and clinical events such as late-onset sepsis and seizures. However, continuous motion monitoring in the NICU setting is not yet performed. Video-based motion monitoring is a promising method due to its non-contact nature and therefore unobtrusiveness. This study aims to determine the feasibility of simple video-based methods for infant body motion detection. We investigated and compared four methods to detect the motion in videos of infants, using two datasets acquired with different types of cameras. The thermal dataset contains 32 hours of annotated videos from 13 infants in open beds. The RGB dataset contains 9 hours of annotated videos from 5 infants in incubators. The compared methods include background substruction (BS), sparse optical flow (SOF), dense optical flow (DOF), and oriented FAST and rotated BRIEF (ORB). The detection performance and computation time were evaluated by the area under receiver operating curves (AUC) and run time. We conducted experiments to detect motion and gross motion respectively. In the thermal dataset, the best performance of both experiments is achieved by BS with mean (standard deviation) AUCs of 0.86 (0.03) and 0.93 (0.03). In the RGB dataset, SOF outperforms the other methods in both experiments with AUCs of 0.82 (0.10) and 0.91 (0.05). All methods are efficient to be integrated into a camera system when using low-resolution thermal cameras.
- Published
- 2022
- Full Text
- View/download PDF
8. Body Motion Detection in Neonates Based on Motion Artifacts in Physiological Signals from a Clinical Patient Monitor.
- Author
-
Peng Z, Lorato I, Long X, Liang RH, Kommers D, Andriessen P, Cottaar W, Stuijk S, and van Pul C
- Subjects
- Electrocardiography, Humans, Infant, Newborn, Monitoring, Physiologic, Motion, Artifacts, Wavelet Analysis
- Abstract
Motion patterns in newborns contain important information. Motion patterns change upon maturation and changes in the nature of motion may precede critical clinical events such as the onset of sepsis, seizures and apneas. However, in clinical practice, motion monitoring is still limited to observations by caregivers. In this study, we investigated a practical yet reliable method for motion detection using routinely used physiological signals in the patient monitor. Our method calculated motion measures with a continuous wavelet transform (CWT) and a signal instability index (SII) to detect gross-motor motion in 15 newborns using 40 hours of physiological data with annotated videos. We compared the performance of these measures on three signal modalities (electrocardiogram ECG, chest impedance, and photo plethysmography). In addition, we investigated whether their combinations increased performance. The best performance was achieved with the ECG signal with a median (interquartile range, IQR) area under receiver operating curve (AUC) of 0.92(0.87-0.95), but differences were small as both measures had a robust performance on all signal modalities. We then applied the algorithm on combined measures and modalities. The full combination outperformed all single-modal methods with a median (IQR) AUC of 0.95(0.91-0.96) when discriminating gross-motor motion from still. Our study demonstrates the feasibility of gross-motor motion detection method based on only clinically-available vital signs and that best results can be obtained by combining measures and vital signs.
- Published
- 2021
- Full Text
- View/download PDF
9. Automatic Separation of Respiratory Flow from Motion in Thermal Videos for Infant Apnea Detection.
- Author
-
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, and de Haan G
- Subjects
- Algorithms, Humans, Infant, Infant, Newborn, Infant, Premature, Motion, Sleep Apnea Syndromes, Sleep Apnea, Obstructive
- Abstract
Both Respiratory Flow (RF) and Respiratory Motion (RM) are visible in thermal recordings of infants. Monitoring these two signals usually requires landmark detection for the selection of a region of interest. Other approaches combine respiratory signals coming from both RF and RM, obtaining a Mixed Respiratory (MR) signal. The detection and classification of apneas, particularly common in preterm infants with low birth weight, would benefit from monitoring both RF and RM, or MR, signals. Therefore, we propose in this work an automatic RF pixel detector not based on facial/body landmarks. The method is based on the property of RF pixels in thermal videos, which are in areas with a smooth circular gradient. We defined 5 features combined with the use of a bank of Gabor filters that together allow selection of the RF pixels. The algorithm was tested on thermal recordings of 9 infants amounting to a total of 132 min acquired in a neonatal ward. On average the percentage of correctly identified RF pixels was 84%. Obstructive Apneas (OAs) were simulated as a proof of concept to prove the advantage in monitoring the RF signal compared to the MR signal. The sensitivity in the simulated OA detection improved for the RF signal reaching 73% against the 23% of the MR signal. Overall, the method yielded promising results, although the positioning and number of cameras used could be further optimized for optimal RF visibility.
- Published
- 2021
- Full Text
- View/download PDF
10. Towards Continuous Camera-Based Respiration Monitoring in Infants.
- Author
-
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, and de Haan G
- Subjects
- Humans, Infant, Monitoring, Physiologic, Motion, Skin, Respiration, Respiratory Rate
- Abstract
Aiming at continuous unobtrusive respiration monitoring, motion robustness is paramount. However, some types of motion can completely hide the respiration information and the detection of these events is required to avoid incorrect rate estimations. Therefore, this work proposes a motion detector optimized to specifically detect severe motion of infants combined with a respiration rate detection strategy based on automatic pixels selection, which proved to be robust to motion of the infants involving head and limbs. A dataset including both thermal and RGB (Red Green Blue) videos was used amounting to a total of 43 h acquired on 17 infants. The method was successfully applied to both RGB and thermal videos and compared to the chest impedance signal. The Mean Absolute Error (MAE) in segments where some motion is present was 1.16 and 1.97 breaths/min higher than the MAE in the ideal moments where the infants were still for testing and validation set, respectively. Overall, the average MAE on the testing and validation set are 3.31 breaths/min and 5.36 breaths/min, using 64.00% and 69.65% of the included video segments (segments containing events such as interventions were excluded based on a manual annotation), respectively. Moreover, we highlight challenges that need to be overcome for continuous camera-based respiration monitoring. The method can be applied to different camera modalities, does not require skin visibility, and is robust to some motion of the infants.
- Published
- 2021
- Full Text
- View/download PDF
11. Multi-camera infrared thermography for infant respiration monitoring.
- Author
-
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, and de Haan G
- Abstract
Respiration is monitored in neonatal wards using chest impedance (CI), which is obtrusive and can cause skin damage to the infants. Therefore, unobtrusive solutions based on infrared thermography are being investigated. This work proposes an algorithm to merge multiple thermal camera views and automatically detect the pixels containing respiration motion or flow using three features. The method was tested on 152 minutes of recordings acquired on seven infants. We performed a comparison with the CI respiration rate yielding a mean absolute error equal to 2.07 breaths/min. Merging the three features resulted in reducing the dependency on the window size typical of spectrum-based features., Competing Interests: The authors declare no conflicts of interest., (© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.)
- Published
- 2020
- Full Text
- View/download PDF
12. A Direct Phase-Tracking Doppler Radar Using Wavelet Independent Component Analysis for Non-Contact Respiratory and Heart Rate Monitoring.
- Author
-
Mercuri M, Liu YH, Lorato I, Torfs T, Wieringa F, Bourdoux A, and Van Hoof C
- Subjects
- Humans, Doppler Effect, Heart Rate, Heart Rate Determination instrumentation, Heart Rate Determination methods, Pulmonary Ventilation, Radar, Respiratory Mechanics
- Abstract
A continuous wave Doppler radar, operating as a phase-locked-loop in phase demodulator configuration, is proposed and in vivo demonstrated for noncontact vital signs monitoring. The radar architecture exhibits a unique precision in tracking the phase modulation caused by human cardiopulmonary activity from which heartbeat and respiration can simultaneously be extracted. The single mixer architecture is immune to the null point and does not require small-angle approximation conditions, which distinguishes it from pre-existing other approaches. This enables the proposed radar to behave highly linear, with very precise detection of phase modulations induced by any kind of movement, independently from amplitude and speed. After simulations and technical tests to validate functionality and safety of the proposed architecture, a practical setup was demonstrated on human volunteers. Wavelet independent component analysis was applied to successfully retrieve respiratory and heart rate information from the radar baseband signal.
- Published
- 2018
- Full Text
- View/download PDF
13. Frequency-Tracking CW Doppler Radar Solving Small-Angle Approximation and Null Point Issues in Non-Contact Vital Signs Monitoring.
- Author
-
Mercuri M, Liu YH, Lorato I, Torfs T, Bourdoux A, and Van Hoof C
- Subjects
- Equipment Design, Humans, Monitoring, Physiologic, Radar, Vital Signs
- Abstract
A Doppler radar operating as a Phase-Locked-Loop (PLL) in frequency demodulator configuration is presented and discussed. The proposed radar presents a unique architecture, using a single channel mixer, and allows to detect contactless vital signs parameters while solving the null point issue and without requiring the small angle approximation condition. Spectral analysis, simulations, and experimental results are presented and detailed to demonstrate the feasibility and the operational principle of the proposed radar architecture.
- Published
- 2017
- Full Text
- View/download PDF