Eppinger S, Piayda K, Galea R, Sandri M, Maarse M, Güner A, Karabay CY, Pershad A, Ding WY, Aminian A, Akin I, Davtyan KV, Chugunov IA, Marijon E, Rosseel L, Schmidt TR, Amabile N, Korsholm K, Lund J, Guerios E, Amat-Santos IJ, Boccuzzi G, Ellis CR, Sabbag A, Ebelt H, Clapp B, Assa HV, Levi A, Ledwoch J, Lehmann S, Lee OH, Mark G, Schell W, Della Rocca DG, Natale A, de Backer O, Kefer J, Esteban PP, Abelson M, Ram P, Moceri P, Galache Osuna JG, Alvarez XM, Cruz-Gonzalez I, de Potter T, Ghassan M, Osadchiy A, Chen W, Goyal SK, Giannini F, Rivero-Ayerza M, Afzal S, Jung C, Skurk C, Langel M, Spence M, Merkulov E, Lempereur M, Shin SY, Mesnier J, McKinney HL, Schuler BT, Armero S, Gheorghe L, Ancona MBM, Santos L, Mansourati J, Nombela-Franco L, Nappi F, Kühne M, Gaspardone A, van der Pals J, Montorfano M, Fernández-Armenta J, Harvey JE, Rodés-Cabau J, Klein N, Sabir SA, Kim JS, Cook S, Kornowski R, Saraste A, Nielsen-Kudsk JE, Gupta D, Boersma L, Räber L, Sievert K, Sievert H, and Bertog S
Background: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication., Objectives: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry., Methods: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes., Results: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients., Conclusions: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful., Condensed Abstract: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high., Competing Interests: Declaration of competing interest A. Aminian is a consultant and proctor for Boston Scientific and Abbott. I. Akin received lecture and proctoring fees from Boston Scientific for the Watchman Okkluder. J. Lund discloses a clinical advisor (proctor) role in LAAC (Abbott) and lecture fees (Abbott, Boston scientific). E. Guerios serves as proctor for LAA closure for Abbott and Lifetech Scientific. N. Amabile has received proctoring and consulting fees from Abbott Vascular and Boston Scientific. C. Skurk has received proctor honoraria from Boston Scientific and speaker fees from Boston Scientific and Lifetech Scientific. J. Harvey is proctor for Abiomed, Boston Scientific and Medtronic and part of the Speaker's bureau for Abiomed, Boston Scientific and Medtronic. He also is part of the advisory board for Avail, Boston Scientific and Medtronic. H. Sievert has received study honoraria to institution, travel expenses and consulting fees from 4tech Cardio, Abbott, Ablative Solutions, Adona Medical, Akura Medical, Ancora Heart, Append Medical, Axon, Bavaria Medizin Technologie GmbH, Bioventrix, Boston Scientific, Cardiac Dimensions, Cardiac Success, Cardimed, Cardionovum, Celonova, Contego, Coramaze, Croivalve, CSL Behring LLC, CVRx, Dinova, Edwards, Endobar, Endologix, Endomatic, Esperion Therapeutics, Inc., Hangzhou Nuomao Medtech, Holistick Medical, Intershunt, Intervene, K2, Laminar, Lifetech, Magenta, Maquet Getinge Group, Metavention, Mitralix, Mokita, Neurotronic, NXT Biomedical, Occlutech, Recor, Renal Guard, Shifamed, Terumo, Trisol, Vascular Dynamics, Vectorious Medtech, Venus, Venock, Vivasure Medical, Vvital Biomed and Whiteswell. M. Kühne received personal fees from Bayer, Böhringer Ingelheim, Pfizer BMS, Daiichi Sankyo, Medtronic, Biotronik, Boston Scientific, Johnson & Johnson, and F. Hoffmann-La Roche Ltd., as well as grants from Bayer, Pfizer, Boston Scientific, BMS, Biotronik, and Daiichi Sankyo. S. Sabir is part of the Boston Scientific WATCHMAN advisory board. J. Kim has received proctoring fees from Abbott Vascular. M. Montorfano received consultant fees from Abbott, Boston Scientific, Kardia. M. Ancona received consultant fees from Abbott. Relevant research funding went to Vanderbilt University Medical Center from Boston Scientific, Boehringer-Ingelheim, Medtronic and Atricure, where C. Ellis is practicing. He also reseves a consultant and advisor fee from Abbott Medical, Atricure, Boston Scientific, Medtronic. L. Nombela-Franco is proctor for Abbott Vascular and has received lectures fees from Boston Scientific. A. Natale has received speaker honoraria from Boston Scientific, Biosense Webster, St. Jude Medical, Biotronik, and Medtronic. He also is a consultant for Biosense Webster, St. Jude Medical, and Janssen. All other authors declare that they have no competing interests., (Copyright © 2024. Published by Elsevier Inc.)