1. The First Round Result from the TianQin-1 Satellite
- Author
-
Bin Cao, Xudong Wang, Shu-Chao Wu, Xingyu Gou, Jia Li, De-Feng Gu, Xiang-Qing Huang, Yan-Wei Ding, Hsien-Chi Yeh, Wei-Ming Chen, Jianwei Mei, Shuang Hu, Guan-Fang Wang, Lijiao Wang, Zhu Li, Jun Luo, Liang-Cheng Tu, Ming-Lin Yang, Yan-Chong Liu, Lihua Zhang, Yu-Rong Liang, Hong-Yin Li, Chao-Zheng Gu, Shan-Qing Yang, Lin Cai, Qu Shaobo, Zhuxi Li, Ran Wei, Pei-Bo Liu, Chun-Yu Xiao, Xiao-Shi Xu, Liang Yang, Yu Chen, Yan Luo, De-Cong Cheng, Meng-Hao Zhao, Zi-Qi He, Ming Li, Jian-Bo Yu, Yanzheng Bai, Yuexin Hu, Hui-Zong Duan, Fang-Jie Liao, Yuan Liu, Jing Wang, Xiong-Fei Lu, Mi Tang, Qinghua Jiang, Zebing Zhou, Honggang Li, Cheng-Rui Wang, Yuan-Ze Jiang, Meng-Zhe Xie, Li Liu, Xuhui Liu, Ding-Yin Tan, Min Ming, and Fengbin Wang
- Subjects
Physics ,Temperature monitoring ,Physics - Instrumentation and Detectors ,Physics and Astronomy (miscellaneous) ,010308 nuclear & particles physics ,business.industry ,FOS: Physical sciences ,Thrust ,Instrumentation and Detectors (physics.ins-det) ,General Relativity and Quantum Cosmology (gr-qc) ,Residual ,01 natural sciences ,Noise (electronics) ,General Relativity and Quantum Cosmology ,Acceleration ,Optics ,0103 physical sciences ,Orbit (dynamics) ,Satellite ,010306 general physics ,business ,Sensitivity (electronics) - Abstract
The TianQin-1 satellite (TQ-1), which is the first technology demonstration satellite for the TianQin project, was launched on 20 December 2019. The first round of experiment had been carried out from 21 December 2019 until 1 April 2020. The residual acceleration of the satellite is found to be about $1\times10^{-10}~{\rm m}/{\rm s}^{2}/{\rm Hz}^{1/2}$ at $0.1~{\rm Hz}\,$ and about $5\times10^{-11}~{\rm m}/{\rm s}^{2}/{\rm Hz}^{1/2}$ at $0.05~{\rm Hz}\,$, measured by an inertial sensor with a sensitivity of $5\times10^{-12}~{\rm m}/{\rm s}^{2}/{\rm Hz}^{1/2}$ at $0.1~{\rm Hz}\,$. The micro-Newton thrusters has demonstrated a thrust resolution of $0.1~\mu{\rm N}$ and a thrust noise of $0.3~\mu{\rm N}/{\rm Hz}^{1/2}$ at $0.1~{\rm Hz}$. The residual noise of the satellite with drag-free control is $3\times10^{-9}~{\rm m}/{\rm s}^{2}/{\rm Hz}^{1/2}$ at $0.1~{\rm Hz}\,$. The noise level of the optical readout system is about $30~{\rm pm}/{\rm Hz}^{1/2}$ at $0.1~{\rm Hz}\,$. The temperature stability at temperature monitoring position is controlled to be about $\pm3~{\rm mK}$ per orbit, and the mismatch between the center-of-mass of the satellite and that of the test mass is measured with a precision of better than $0.1~{\rm mm}$., Comment: 17 pages, 11 figures
- Published
- 2020
- Full Text
- View/download PDF