Abstract Background 16S rDNA-PCR for the identification of a bacterial species is an established method. However, the DNA extraction reagents as well as the PCR reagents may contain residual bacterial DNA, which consequently generates false-positive PCR results. Additionally, previously used methods are frequently time-consuming. Here, we describe the results obtained with a new technology that uses DNA-free reagents for automated DNA extraction and subsequent real time PCR using sterile clinical specimens. Results In total, we compared 803 clinical specimens using real time PCR and culturing. The clinical specimens were mainly of orthopedic origin received at our diagnostic laboratory. In 595 (74.1%) samples, the results were concordant negative, and in 102 (12.7%) the results were concordant positive. A total of 170 (21.2%) clinical specimens were PCR-positive, of which 62 (36.5% from PCR positive, 7.7% in total) gave an additional benefit to the patient since only the PCR result was positive. Many of these 62 positive specimens were strongly positive based on crossingpoint values (54%