1. Nocturnal oxygen saturation profiles of healthy term infants
- Author
-
C. Parsley, Carolyn Dakin, Philip I. Terrill, Maggie Yuill, and Ian P. Hughes
- Subjects
Male ,Percentile ,medicine.medical_specialty ,Pediatrics ,Technology ,Term Birth ,Polysomnography ,Nocturnal ,Cohort Studies ,Reference Values ,Internal medicine ,medicine ,Humans ,Longitudinal Studies ,Oximetry ,Prospective Studies ,Longitudinal cohort ,Prospective cohort study ,Oxygen saturation ,Measurement ,medicine.diagnostic_test ,business.industry ,Infant, Newborn ,Infant ,Oxygen ,Pulse oximetry ,Pediatrics, Perinatology and Child Health ,Cardiology ,Respiratory ,Original Article ,Female ,business ,Sleep ,Cohort study - Abstract
ObjectivePulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants.DesignProspective longitudinal cohort study.SettingSleep-laboratory.Patients34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively).InterventionsFull overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical).Main outcome measurementsSummary SpO2statistics (mean, median, 5th and 10th percentiles) and SpO2CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal.ResultsMedian nocturnal SpO2values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake.ConclusionsSpO2CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants.
- Published
- 2014