1. Rapid, sensitive and selective HPLC–MS/MS method for the quantification of topically applied besifloxacin in rabbit plasma and ocular tissues: Application to a pharmacokinetic study
- Author
-
Bin Di, Yang Yang, Mengxiang Su, Da-song Yang, Jia-Li Zhang, Bai-Yang Mao, Xiao-Fei Gu, Wei-Xin Wu, Ying-Xiang Du, and Min Xia
- Subjects
Male ,Analyte ,Time Factors ,Administration, Topical ,Electrospray ionization ,Clinical Biochemistry ,Pharmaceutical Science ,Administration, Ophthalmic ,Nateglinide ,Tandem mass spectrometry ,01 natural sciences ,Analytical Chemistry ,Aqueous Humor ,Cornea ,03 medical and health sciences ,0302 clinical medicine ,Pharmacokinetics ,Tandem Mass Spectrometry ,Liquid chromatography–mass spectrometry ,Drug Discovery ,medicine ,Animals ,Chromatography, High Pressure Liquid ,Spectroscopy ,Chromatography ,Chemistry ,Besifloxacin ,010401 analytical chemistry ,Selected reaction monitoring ,Azepines ,0104 chemical sciences ,030221 ophthalmology & optometry ,Rabbits ,Conjunctiva ,Fluoroquinolones ,medicine.drug - Abstract
Besifloxacin is a fourth-generation broad-spectrum fluoroquinolone registered for the topical treatment of bacterial conjunctivitis. In this study, a rapid, sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for quantification of besifloxacin in rabbit plasma and ocular tissues using nateglinide as the internal standard (IS). The analyte and IS were separated on a Sepax GP-Phenyl column by isocratic elution with methanol-acetonitrile-5 mM ammonium formate-formic acid (29:55:16:0.1, v/v/v/v) as the mobile phase at a flow rate of 1.2 mL/min, and the total run time was 3.0 min. An electrospray ionization (ESI) source was applied and operated in the positive ion mode; multiple reaction monitoring (MRM) mode was used for quantification, and the monitored transitions were 394.2→377.1 for besifloxacin and m/z 318.3→166.1 for the IS. The calibration curve was linear over the range of 0.103-206 ng/mL for plasma and 2.06-2060 ng/mL for tears, aqueous humor, conjunctiva and cornea with correlation coefficient (r) greater than 0.99. The lower limit of quantification (LLOQ) for besifloxacin was 0.103 ng/mL for plasma and 2.06 ng/mL for other ocular tissues with good accuracy and precision. Intra- and inter-batch precision were both lower than 15% and accuracy ranged from 85% to 115% at all QC levels. The method was successfully applied to the pharmacokinetic study of besifloxacin in rabbit plasma and ocular tissues after single and multiple topical administrations.
- Published
- 2016
- Full Text
- View/download PDF