1. Esophageal manometry in systemic sclerosis: findings and association with clinical manifestations
- Author
-
Rogério de Melo Costa Pinto, Roberto Ranza, Abadia Gilda Buso Matoso, and Juliana Markus
- Subjects
medicine.medical_specialty ,Manometry ,systemic sclerosis ,Cross-sectional study ,Systemic Sclerosis ,Interstitial Lung Disease ,Gastroenterology ,Scleroderma ,03 medical and health sciences ,Esophagus ,0302 clinical medicine ,Fibrosis ,Internal medicine ,medicine ,Outpatient clinic ,Esôfago ,esophagus ,interstitial lung disease ,030203 arthritis & rheumatology ,lcsh:R5-920 ,Lung ,business.industry ,Interstitial lung disease ,Doenças pulmonares intersticiais ,manometry ,General Medicine ,Escleroderma sistêmico ,medicine.disease ,medicine.anatomical_structure ,Manometria ,Etiology ,030211 gastroenterology & hepatology ,lcsh:Medicine (General) ,business - Abstract
SUMMARY INTRODUCTION Systemic sclerosis (SSC) is an autoimmune disorder that affects several organs of unknown etiology, characterized by vascular damage and fibrosis of the skin and organs. Among the organs involved are the esophagus and the lung. OBJECTIVES To relate the profile of changes in esophageal electromanometry (EM), the profile of skin involvement, interstitial pneumopathy (ILD), and esophageal symptoms in SSC patients. METHODS This is an observational, cross-sectional study carried out at the SSC outpatient clinic of the Hospital de Clínicas of the Federal University of Uberlândia. After approval by the Ethics Committee and signed the terms of consent, 50 patients were initially enrolled, from 04/12/2014 to 06/25/2015. They were submitted to the usual investigations according to the clinical picture. The statistical analysis was descriptive in percentage, means, and standard deviation. The Chi-square test was used to evaluate the relationship between EM, high-resolution tomography, and esophageal symptoms. RESULTS 91.9% of the patients had some manometric alterations. 37.8% had involvement of the esophageal body and lower esophageal sphincter. 37.8% had ILD. 24.3% presented the diffuse form of SSC. No association was found between manometric changes and clinical manifestations (cutaneous, pulmonary, and gastrointestinal symptoms). CONCLUSION The present study confirms that esophageal motility alterations detected by EM are frequent in SSC patients, but may not be related to cutaneous extension involvement, the presence of ILD, or the gastrointestinal complaints of patients. RESUMO INTRODUÇÃO A esclerose sistêmica (ES) é uma doença autoimune que afeta vários órgãos de etiologia desconhecida, caracterizada por dano vascular e fibrose da pele e órgãos. Entre os órgãos envolvidos estão o esôfago e o pulmão. OBJETIVOS Relacionar o perfil das alterações na eletromanometria (ME), o perfil de acometimento da pele, a pneumopatia intersticial (PI) e os sintomas esofágicos em pacientes com ES. MÉTODO Trata-se de um estudo observacional, transversal, realizado no ambulatório de SSC do Hospital das Clínicas da Universidade Federal de Uberlândia. Após aprovação pelo Comitê de Ética e assinatura dos termos de consentimento, 50 pacientes foram inicialmente convidados, de 04/12/2014 a 25/06/2015. Eles foram submetidos às investigações usuais de acordo com o quadro clínico. A análise estatística foi descritiva em porcentagem, média e desvio padrão. O teste Qui-quadrado foi utilizado para avaliar a relação entre ME, tomografia de alta resolução e sintomas esofágicos. RESULTADOS 91,9% dos pacientes apresentaram alterações manométricas. 37,8% tinham envolvimento do corpo esofágico e do esfíncter esofágico inferior. 37,8% tinham IP. 24,3% apresentaram a forma difusa da ES. Não há associação entre alterações manométricas e manifestações clínicas (sintomas cutâneos, pulmonares e gastrointestinais). CONCLUSÃO O presente estudo confirma que as alterações da motilidade esofágica detectadas pela EM são frequentes em pacientes com SSC, mas podem não estar relacionadas ao envolvimento cutâneo, à de DPI ou às queixas gastrointestinais dos pacientes.
- Published
- 2020