1. Mechanical Contribution of the Rib Cage in the Human Cadaveric Thoracic Spine.
- Author
-
Mannen EM, Anderson JT, Arnold PM, and Friis EA
- Subjects
- Aged, Biomechanical Phenomena, Bone Nails, Cadaver, Elasticity, Humans, Middle Aged, Osteotomy, Prosthesis Design, Prosthesis Implantation instrumentation, Range of Motion, Articular, Ribs anatomy & histology, Ribs surgery, Rotation, Thoracic Vertebrae anatomy & histology, Thoracic Vertebrae surgery, Ribs physiology, Thoracic Vertebrae physiology
- Abstract
Study Design: An in vitro biomechanical human cadaveric study of T1-T12 thoracic specimens was performed with 4 conditions (with and without rib cage, instrumented and uninstrumented) in flexion-extension, lateral bending, and axial rotation., Objective: The objective was to understand the influence of the rib cage on motion and stiffness parameters of the human cadaveric thoracic spine. Hypotheses tested for overall motion in all modes of bending for both uninstrumented and instrumented specimens were (i) in-plane range of motion and neutral and elastic zones will be greater without the rib cage, (ii) neutral and elastic zone stiffness values will be different for specimens without the rib cage, and (iii) out-of-plane rotations will be different for specimens without the rib cage., Summary of Background Data: The rib cage is presumed to provide significant stability to the thoracic spine, but no studies have been conducted to determine the influence of the rib cage in both uninstrumented and instrumented conditions in the full thoracic human cadaveric specimens., Methods: Seven human cadaveric spine specimens (T1-T12) with 4 conditions (with and without rib cage, instrumented and uninstrumented) were subjected to 5 N·m pure moments in flexion-extension, lateral bending, and axial rotation. Range of motion, neutral and elastic zones, neutral and elastic zone stiffness values, and out-of-plane rotations were calculated for the overall specimen., Results: In-plane range of motion was significantly higher without a rib cage for most modes of bending. Out-of-plane motions were also influenced by the rib cage. Neutral zone stiffness was significantly higher with a rib cage present., Conclusion: Testing without a rib cage yields different motion and stiffness measures, directly impacting the translation of research results to clinical interpretation. Researchers should consider these differences when evaluating the mechanical impact of surgical procedures or instrumentation in cadaveric or computational models., Level of Evidence: 5.
- Published
- 2015
- Full Text
- View/download PDF