1. Demand Side Management Effects on Substation Transformer Capacity Limits.
- Author
-
McBee, Kerry D., Chong, Jacquelyn, and Rudraraju, Prasanth
- Subjects
LOAD management (Electric power) ,POWER transformers ,ELECTRIC transformers ,ELECTRIC charge ,ELECTRIC vehicles ,DRUG side effects ,ENERGY storage ,EMERGENCY management - Abstract
Featured Application: The research provides insight into the effects that high penetrations of photovoltaic (PV) systems, energy storage (ES) applications, and electric vehicle (EV) charging systems will have on substation transformer capacity ratings. The manuscript identifies how these applications change the operational conditions of a transformer to the point where capacity ratings (normal and emergency) should be adjusted to account for the additional internal heating in the windings and oil. The research also identifies how harmonic distortion induced by PV, ES, and EV charging equipment affects capacity ratings. The results of the analysis are utilized to describe mitigating approaches for existing units and new units being designed. The approaches are applied to the design attributes of a 50 MVA SPX Waukesha transformer. In high penetrations, demand side management (DMS) applications augment a substation power transformer's load profile, which can ultimately affect the unit's capacity limits. Energy storage (ES) applications reduce the evening peaking demand, while time-of-use rates incentivize end-users to charge electric vehicles overnight. The daily load profile is further augmented by high penetrations of photovoltaic (PV) systems, which reduce the midday demand. The resulting load profile exhibits a more flattened characteristic when compared to the historical cyclic profile. Although the initial impact of PV and ES applications may reduce a unit's peak demand, long-term system planning and emergency conditions may require operation near or above the nameplate rating. Researchers have already determined that a flattened load profile excessively ages a unit's dielectrics more rapidly. The focus of this research was to identify an approach for establishing new transformer capacity limits for units serving flattened load profiles with a high harmonic content. The analysis utilizes IEEE standards C57.91 and C57.110 to develop an aging model of a 50 MVA SPX Waukesha transformer. The results establish a guideline for determining transformer capacity limits for normal operation, long-term emergency operation, and short-term emergency operation when serving systems with high penetrations of DSM applications. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF