1. Transient Hydraulic Performance of a Prototype Pump during Starting and Stopping Periods.
- Author
-
Zheng, Shao-Han, Ye, Jian-Gang, Zhao, Yan-Juan, Zhang, Yu-Liang, and Jia, Xiao-Qi
- Subjects
CENTRIFUGAL pumps ,IMPELLERS ,RUNNING speed ,FUEL pumps ,PROTOTYPES - Abstract
In order to meet different operational requirements, existing low specific speed centrifugal pumps may have to be run at high speeds. Therefore, it is crucial to understand the transient performance of such centrifugal pumps during high speed starting and stopping. However, there are currently no experiments on the starting and stopping of low specific speed centrifugal pumps. In this paper, transient hydraulic performance experiments during starting and stopping had been carried out on an atypical open impeller centrifugal pump with a rated flow rate of 6 m
3 /h using an updated test rig. The correlation of speed, flow, head and shaft power with time was obtained for four flow ratios of 0.353, 1.022, 1.654 and 2.343 operating conditions. It was found that the fluctuation of the shaft power curve was the strongest during the starting process, and there was a significant impact phenomenon. The corresponding impact shaft power from small to large flow rates were 0.167 kW, 0.409 kW, 0.234 kW and 0.215 kW, and the shaft power impact phenomenon was the most obvious under rated operating conditions. During the stopping process, the speed, flow rate and head all remain stable for a small period of time, and the time required to decrease to 0 is longer than the time required to reach a stable state during starting. During stopping, the shaft power will instantly decrease, accompanied by varying degrees of fluctuations. [ABSTRACT FROM AUTHOR]- Published
- 2023
- Full Text
- View/download PDF