1. Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes.
- Author
-
Lee DW, Li AC, Ko CW, Chu DW, Chan KC, Poon CM, Sin KS, Leung KF, Sze TS, Chan AC, and Chung SC
- Subjects
- Adolescent, Adult, Aged, Dose-Response Relationship, Drug, Equipment Design, Female, Follow-Up Studies, Hospitals, University, Humans, Male, Middle Aged, Pain Measurement, Patient Satisfaction, Prospective Studies, Treatment Outcome, Alfentanil administration & dosage, Anesthetics, Intravenous administration & dosage, Colonoscopes, Colonoscopy methods, Conscious Sedation methods, Propofol administration & dosage
- Abstract
Background: The variable-stiffness colonoscope incorporates different degrees of stiffness of the insertion tube, which can be adjusted during the examination. Whether its use can lead to reduced procedure-related pain and sedative use is unknown., Objective: Our purpose was to compare the use of 3 types of colonoscope with different shaft stiffnesses in relation to procedure-related pain and sedative consumption., Design: Prospective randomized trial., Setting: Endoscopy unit of a university-affiliated hospital., Patients: Consecutive patients undergoing ambulatory colonoscopy., Interventions: Random assignment was made of patients into 3 groups to receive colonoscopic examinations by one of the 3 types of colonoscope: conventional standard adult size, 1.3-m; 1.6-m; and the new variable-stiffness adult size, full-length (1.6-m) colonoscope. A mixture of propofol and afentanil, delivered by a patient-controlled syringe pump, was used for sedation in all groups., Main Outcome Measures: Outcome measures included dose of patient-controlled sedation consumed, pain score, cecal intubation rate, cecal intubation time, requirement of abdominal pressure and change of patients' positions during colonoscopy, and endoscopists and patients' satisfaction scores according to a visual analog scale., Results: A total of 335 patients were randomized. Patients in group 3 used significantly less propofol (in milligrams per kilograms, mean [SD]) compared with the other 2 groups (group 1: 1.00 [0.75], group 2: 0.93 [0.62], and group 3: 0.75 [0.65]; P = .02; 1-way analysis of variance). The mean (SD) pain score was also lower in group 3., Limitations: The endoscopists were not blinded., Conclusion: The use of the new variable-stiffness adult-size colonoscope significantly reduced procedure-related pain and doses of sedative medications during colonoscopy.
- Published
- 2007
- Full Text
- View/download PDF