1. A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device.
- Author
-
van Riet PA, Larghi A, Attili F, Rindi G, Nguyen NQ, Ruszkiewicz A, Kitano M, Chikugo T, Aslanian H, Farrell J, Robert M, Adeniran A, Van Der Merwe S, Roskams T, Chang K, Lin F, Lee JG, Arcidiacono PG, Petrone M, Doglioni C, Iglesias-Garcia J, Abdulkader I, Giovannini M, Bories E, Poizat F, Santo E, Scapa E, Marmor S, Bucobo JC, Buscaglia JM, Heimann A, Wu M, Baldaque-Silva F, Moro CF, Erler NS, Biermann K, Poley JW, Cahen DL, and Bruno MJ
- Subjects
- Adenocarcinoma diagnosis, Adenocarcinoma pathology, Aged, Carcinoma diagnosis, Carcinoma, Squamous Cell diagnosis, Carcinoma, Squamous Cell pathology, Endosonography, Female, Gastrointestinal Stromal Tumors diagnosis, Humans, Image-Guided Biopsy instrumentation, Intestinal Neoplasms diagnosis, Lymphadenopathy diagnosis, Lymphatic Metastasis, Lymphoma diagnosis, Male, Middle Aged, Multivariate Analysis, Needles, Neuroendocrine Tumors diagnosis, Odds Ratio, Pancreatic Neoplasms diagnosis, Pancreatitis, Chronic diagnosis, Pancreatitis, Chronic pathology, Sensitivity and Specificity, Biopsy, Large-Core Needle instrumentation, Carcinoma pathology, Endoscopic Ultrasound-Guided Fine Needle Aspiration instrumentation, Gastrointestinal Stromal Tumors pathology, Intestinal Neoplasms pathology, Lymphadenopathy pathology, Lymphoma pathology, Neuroendocrine Tumors pathology, Pancreatic Neoplasms pathology
- Abstract
Background and Aims: Several studies have compared EUS-guided FNA with fine-needle biopsy (FNB), but none have proven superiority. We performed a multicenter randomized controlled trial to compare the performance of a commonly used 25-gauge FNA needle with a newly designed 20-gauge FNB needle., Methods: Consecutive patients with a solid lesion were randomized in this international multicenter study between a 25-gauge FNA (EchoTip Ultra) or a 20-gauge FNB needle (ProCore). The primary endpoint was diagnostic accuracy for malignancy and the Bethesda classification (non-diagnostic, benign, atypical, malignant). Technical success, safety, and sample quality were also assessed. Multivariable and supplementary analyses were performed to adjust for confounders., Results: A total of 608 patients were allocated to FNA (n = 306) or FNB (n = 302); 312 pancreatic lesions (51%), 147 lymph nodes (24%), and 149 other lesions (25%). Technical success rate was 100% for the 25-gauge FNA and 99% for the 20-gauge FNB needle (P = .043), with no differences in adverse events. The 20-gauge FNB needle outperformed 25-gauge FNA in terms of histologic yield (77% vs 44%, P < .001), accuracy for malignancy (87% vs 78%, P = .002) and Bethesda classification (82% vs 72%, P = .002). This was robust when corrected for indication, lesion size, number of passes, and presence of an on-site pathologist (odds ratio, 3.53; 95% confidence interval, 1.55-8.56; P = .004), and did not differ among centers (P = .836)., Conclusion: The 20-gauge FNB needle outperformed the 25-gauge FNA needle in terms of histologic yield and diagnostic accuracy. This benefit was irrespective of the indication and was consistent among participating centers, supporting the general applicability of our findings. (Clinical trial registration number: NCT02167074.)., (Copyright © 2019 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF