1. Abstract 17230: Transcatheter Leak Occlusion With Endovascular Coils Following Left Atrial Appendage Closure
- Author
-
G. Joseph Gallinghouse, Rodney Horton, Chintan Trivedi, Mohamed Bassiouny, Luigi Di Biase, Nicola Tarantino, Amin Al-Ahmad, Carola Gianni, Andrea Natale, Javier Sanchez, Domenico G. Della Rocca, Jorge Romero, and Sanghamitra Mohanty
- Subjects
Appendage ,medicine.medical_specialty ,Leak ,business.industry ,Closure (topology) ,Atrial fibrillation ,medicine.disease ,Surgery ,Left atrial ,Physiology (medical) ,Occlusion ,medicine ,Cardiology and Cardiovascular Medicine ,business ,Stroke - Abstract
Introduction: The Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures (TREASURE) is a prospective, nonrandomized, single-center study. This study was undertaken to investigate the efficacy of transcatheter leak closure with endovascular coils in patient with incomplete percutaneous/epicardial left atrial appendage (LAA) closure procedures and high thromboembolic (TE)- and bleeding-risk. Hypothesis: We report the efficacy of transcatheter leak closure with endovascular coils in patients with incomplete LAA closure. Methods: Sixty-five consecutive patients with a clinically relevant residual leak (mean age: 72±8 years; 73.8% males; CHA 2 DS 2 -VASc: 4.7±1.1; HAS-BLED: 3.7±0.7) underwent percutaneous closure of the LAA patency via embolization coils. Trans-esophageal echocardiography (TEE) was performed at 60±15 days post-procedure. Results: LAA closure had been previously attempted with a Watchman device in 62 patients, and a LARIAT in 3. Baseline TEE documented a moderate or severe leak in 14 (21.5%) and 51 (78.5%) patients, respectively. Procedure and fluoroscopy times were 69±37min and 22±15min, respectively; the mean volume of iodinated contrast medium used was 82±43mL. Coil deployment was successful in all cases [median n. of coils attempted: 3 (IQR:2-5); median n. of coils deployed: 3 (IQR: 2-4)]. The overall complication rate was 3.1% (1 pericardial tamponade, 1 pericardial effusion). Peri-procedural angiographic and TEE outcomes demonstrated complete obliteration or a negligible residual opacification with a trivial residual jet in 62 cases (95.4%), and a partial occlusion with moderate residual jet in 3 (6.4%). Follow-up TEE after 67±12 days revealed complete LAA sealing or a negligible residual leak in 63 cases (96.9%). Coil deployment led to an average reduction of 90.1% in leak size (p Conclusions: Transcatheter LAA leak occlusion via endovascular coils appears to be a safe, effective, and promising approach in high TE-risk patients with incomplete LAA closure.
- Published
- 2020
- Full Text
- View/download PDF