1. P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
- Author
-
A Barout, Yong-Mei Cha, S Asirvatham, A Izath, Medhat Farwati, Paul A. Friedman, Y Assaf, D Padmanabhan, Joel P. Felmlee, Anas Abudan Al-Masry, S Gamero, Danesh Kella, Robert E. Watson, and D Shetty
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Meta-analysis ,medicine ,Magnetic resonance imaging ,In patient ,Radiology ,Electronics ,Cardiology and Cardiovascular Medicine ,business - Abstract
Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None
- Published
- 2019
- Full Text
- View/download PDF