2. Posterior wall isolation via a multi-electrode radiofrequency balloon catheter: feasibility, technical considerations, endoscopic findings and comparison with cryoballoon technologies.
- Author
-
Del Monte A, Chierchia GB, Della Rocca DG, Pannone L, Sorgente A, Bala G, Monaco C, Mouram S, Capulzini Cremonini L, Audiat C, Praet J, Ramak R, Overeinder I, Ströker E, Sieira J, La Meir M, Brugada P, Sarkozy A, de Asmundis C, and Almorad A
- Subjects
- Humans, Feasibility Studies, Treatment Outcome, Recurrence, Catheters, Cryosurgery methods, Catheter Ablation methods, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Pulmonary Veins surgery
- Abstract
Background: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA)., Methods: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience., Results: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise., Conclusions: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures., (© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2024
- Full Text
- View/download PDF
3. Impact of anesthetic management on catheter ablation for premature ventricular complexes: insights during the COVID-19 outbreak.
- Author
-
Kazawa S, Sieira J, Bala G, Miraglia V, Al Housari M, Strazdas A, Monaco C, Pannone L, Bisignani A, Overeinder I, Almorad A, Raes M, Weyns M, Ghijselings I, Beckers S, Brugada P, Chierchia GB, de Asmundis C, and Ströker E
- Subjects
- Humans, Anesthesia, Local, Treatment Outcome, COVID-19, Ventricular Premature Complexes surgery, Catheter Ablation methods, Anesthetics
- Abstract
Background: The influence of divergent anesthesia types during ablation of premature ventricular complexes (PVCs) is not known. While previously performed under general anesthesia (GA) at our institution, these procedures were exclusively performed under local anesthesia (LA) ± minimal sedation during the COVID-19 outbreak for logistic reasons., Methods: One hundred and eight consecutive patients (82 GA versus 26 LA) undergoing PVC ablation at our center were evaluated. Intraprocedural PVC burden (over 3 min) pre-ablation was measured twice: (1) at the start (before GA induction) and (2) before catheter insertion (after GA induction). Upon cessation of ablation and after a waiting period of ≥ 15 min, acute ablation success (AAS) was defined as absence of PVCs until the end of the recording period., Results: Intraprocedural PVC burden was not significantly different between LA versus GA group: (1) 17.8 ± 3% vs 12.7 ± 2%, P = 0.17 and (2) 10.0 ± 3% vs 7.4 ± 1%, P = 0.43, respectively. Activation mapping-based ablation was performed significantly more in the LA vs GA group (77% vs 26% of patients, P < 0.001, respectively). AAS was significantly higher in LA vs GA group: 22/26 (85%) vs 41/82 (50%), respectively, P < 0.01. After multivariable analysis, LA was the only independent predictor for AAS (OR 13, 95% CI 1.57-107.4, P = 0.017)., Conclusion: Ablation of PVC under LA presented significantly higher AAS rate compared to GA. The procedure under GA might be complicated by PVC inhibition (after catheter insertion/during mapping) and PVC disinhibition post-extubation., (© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2023
- Full Text
- View/download PDF
4. Pulmonary vein size is associated with reconnection following cryoballoon ablation of atrial fibrillation.
- Author
-
Mugnai G, Cecchini F, Stroker E, Paparella G, Iacopino S, Sieira J, De Greef Y, Tomasi L, Bolzan B, Bala G, Overeinder I, Almorad A, Gauthey A, Sorgente A, Ribichini FL, de Asmundis C, and Chierchia GB
- Subjects
- Humans, Middle Aged, Aged, Pulmonary Veins surgery, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery
- Abstract
Background: The second-generation cryoballoon (CB) has proven to be a highly effective ablative strategy in patients with symptomatic atrial fibrillation (AF). This study sought to investigate the anatomical characteristics of pulmonary veins (PVs) and the relationship between their size, ovality, and late reconnections in a large cohort of patients undergoing repeat ablation for recurrence of atrial arrhythmias., Methods and Results: A total of 152 consecutive patients (98 males, 64.5%; mean age 64.9 ± 9.6 years) underwent a repeat ablation for recurrent atrial tachyarrhythmias after a median time of 6.5 months [IQR 11] from the index CB ablation. All repeat ablations were performed using a 3-dimensional electro-anatomical mapping system. Among all 593 PVs, 134 (22.6%) showed a late PV reconnection in 95 patients (0.88 per patient), at the time of repeat ablation procedure. There was a significant difference in ovality between left- and right-sided PVs (p < 0.001). Greater diameters of left superior PV, left inferior PV, and right inferior PV ostia (both maximum and minimum) and higher index ovality were significantly associated with late PV reconnection., Conclusions: The rate of late PV reconnection after CB ablation was low (0.88 PVs/patient). Left-sided PVs were more oval than septal PVs. Larger PV dimensions and higher ovality index were significantly associated with reconnections in all PVs except for RSPV., (© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
5. Comparison between the novel diamond temp and the classical 8-mm tip ablation catheters in the setting of typical atrial flutter.
- Author
-
Ramak R, Lipartiti F, Mojica J, Monaco C, Bisignani A, Eltsov I, Sorgente A, Capulzini L, Paparella G, Deruyter B, Iacopino S, Motoc AI, Luchian ML, Osorio TG, Overeinder I, Bala G, Almorad A, Ströker E, Sieira J, Jordaens L, Brugada P, de Asmundis C, and Chierchia GB
- Subjects
- Catheters, Diamond, Humans, Temperature, Treatment Outcome, Tricuspid Valve surgery, Atrial Flutter surgery, Catheter Ablation methods
- Abstract
Purpose: Radiofrequency (RF) catheter ablation is widely accepted as a first-line therapy for cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). The novel DiamondTemp (DT) catheter with temperature feedback during RF ablation has been released recently on the market. The purpose of this study was to evaluate the impact of DiamondTemp (DT) technology on ablation efficiency during AFL., Methods: In this single-center study, 30 consecutive patients with typical AFL indicated to ablation of CTI were included. The first 15 patients underwent CTI ablation using 8-mm tip catheter, and the following 15 patients underwent temperature-controlled RF ablation using DT catheter. The endpoints were number and mean total duration of RF applications, mean temperature reached in the setting of CTI, procedural times, and fluoroscopy times., Results: There were no significant differences between the two groups concerning baseline characteristics. Mean duration of the each application (71.5 s ± 30.6 vs 12.4 s ± 13.2, p value < 0.001), mean total duration of RF applications (517,73 s ± 377,96 vs 112,8 s ± 43,58; p value < 0.001), procedural times (51.6 min ± 24.2 vs 38.6 ± 8.2; p = 0.03), and fluoroscopy times (16.2 min ± 10.2 vs 8 min ± 4.24; p = 0.005) were longer in the 8-mm ablation catheter group. Mean temperature measurements (51.9 °C ± 3.59 vs 56.7 °C ± 3.34, p value < 0.003) were as well lower in the 8-mm ablation catheter group., Conclusions: Catheter ablation of CTI-dependent AFL by means of DT resulted in a significant reduction of total and single application RF delivery time, procedure, and fluoroscopy times., (© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
6. The optimized clinical workflow for pulmonary vein isolation with the radiofrequency balloon.
- Author
-
Almorad A, Chierchia GB, Pannone L, Osorio TG, Sorgente A, Bisignani A, Bala G, Overeinder I, Ströker E, Brugada P, Sieira J, and de Asmundis C
- Subjects
- Humans, Treatment Outcome, Workflow, Atrial Fibrillation etiology, Atrial Fibrillation surgery, Catheter Ablation methods, Pulmonary Veins surgery, Radiofrequency Ablation methods
- Abstract
Purpose: Pulmonary vein isolation (PVI) with radiofrequency (RF) catheter ablation is an effective treatment option for patients with paroxysmal AF. However, traditional point by point RF ablation can be time consuming and technically challenging. To simplify the ablation procedure, without compromising procedure outcome, several "single shot" ablation systems have been developed. The multi-electrode RF Balloon catheter HELIOSTAR is a 28-mm compliant balloon compatible with the CARTO 3D electroanatomical mapping system; an optimized step-by-step workflow to perform PVI is described., Methods: Procedures are performed under general anesthesia with unique transseptal puncture. To evaluate the optimal electrode-tissue contact and best RF Balloon positioning, the following baseline indicators should be fulfilled: inflation index > 0.8, impedance range close to 100 Ohms with a variability of less than 20 Ohms across electrodes, temperature variability on all electrodes < 3 °C with a maximum temperature of 31 °C., Results: RF delivery along the posterior wall is programmed to 20 s or shorter in case of esophageal temperature rise (> 2 °C compared to baseline) and 60 s for all the other segments. Target parameters for PVI are 1) time to isolation less than 12 s; 2) impedance drop > 12 Ohms; 3) temperature rise > 6 °C., Conclusions: Standardized workflow for RF Balloon is mandatory to achieve efficacy and safety with this new promising technology. In the absence of international guidelines, a single high-volume center procedural strategy is described for PVI., (© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
7. Single procedural outcomes in the setting of percutaneous ablation for persistent atrial fibrillation: a propensity-matched score comparison between different strategies.
- Author
-
Bisignani A, Cecchini F, Mugnai G, Overeinder I, Sieira J, Osório TG, Miraglia V, Monaco C, Sofianos D, Boveda S, Bala G, Ströker E, Paparella G, Westra SW, Brouwer MA, Brugada P, de Asmundis C, and Chierchia GB
- Subjects
- Humans, Propensity Score, Recurrence, Tachycardia surgery, Treatment Outcome, Atrial Fibrillation surgery, Catheter Ablation methods, Cryosurgery methods, Pulmonary Veins surgery
- Abstract
Background: Catheter ablation for persistent atrial fibrillation (persAF) is associated with less favorable outcomes than for paroxysmal AF. To improve success rates, left atrial (LA) substrate modification is frequently performed in addition to pulmonary vein isolation (PVI). The purpose of the study was to compare 4 different ablation approaches using radiofrequency catheter ablation (RFCA) or cryoballoon ablation (CB-A) for persAF and to evaluate the respective outcomes on a midterm follow-up of 12 months., Methods: We did a propensity score-matched comparison of 30 patients undergoing PVI + LA posterior wall isolation (LAPWI) with CB-A, 30 patients who underwent PVI + linear ablation (roof and mitral lines) using RFCA, 60 patients with PVI alone using CB-A, and 60 patients who had PVI alone using RFCA. The endpoint was recurrence of documented atrial tachyarrhythmias (ATas) > 30 s at 1-year follow-up., Results: After 12 months, freedom from ATas after a single procedure was 83.3% in the PVI + LAPWI group, 46.7% in the PVI + linear ablation group, 58.3% in the PVI-alone CB-A group, and 61.6% PVI-alone RFCA (p = 0.03). Moreover, freedom from ATas was significantly higher comparing the PVI + LAPWI group with each of the other groups., Conclusions: In this propensity-matched comparison of strategies for persAF, LAPW ablation in addition to PVI with CB-A seems to improve 1-year outcome in comparison to PVI + linear ablation using RFCA and to PVI alone using RFCA or CB-A. Randomized comparisons are eagerly awaited., (© 2021. Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
8. Sinus node sparing novel hybrid approach for treatment of inappropriate sinus tachycardia/postural sinus tachycardia: multicenter experience.
- Author
-
de Asmundis C, Chierchia GB, Lakkireddy D, Romeya A, Okum E, Gandhi G, Sieira J, Vloka M, Jones SD, Shah H, Winner M, Patel D, Whalen SP, Beaty EH, Kincaid EH, Lee A, Brodt C, Taylor BJ, Colombowala I, Romano M, Morady F, Ströker E, Overeinder I, Bala G, Van Meeteren J, Krauthammer Y, Koerber S, Shults C, Thomaides A, Badhwar N, Gopinathannair R, Shah A, Tummala R, Bello D, Hoff S, Almorad A, Frazier K, Brugada P, and La Meir M
- Subjects
- Endocardium surgery, Female, Humans, Sinoatrial Node surgery, Tachycardia, Sinus diagnosis, Catheter Ablation methods, Postural Orthostatic Tachycardia Syndrome diagnosis
- Abstract
Background: The ideal treatment of inappropriate sinus tachycardia (IST) and postural orthostatic tachycardia syndrome (POTS) still needs to be defined. Medical treatments yield suboptimal results. Endocardial catheter ablation of the sinus node (SN) may risk phrenic nerve damage and open-heart surgery may be accompanied by unjustified invasive risks., Methods: We describe our first multicenter experience of 255 consecutive patients (235 females, 25.94 ± 3.84 years) having undergone a novel SN sparing hybrid thoracoscopic ablation for drug-resistant IST (n = 204, 80%) or POTS (n = 51, 20%). As previously described, the SN was identified with 3D mapping. Surgery was performed through three 5-mm ports from the right side. A minimally invasive approach with a bipolar radiofrequency clamp was used to ablate targeted areas while sparing the SN region. The targeted areas included isolation of the superior and the inferior caval veins, and a crista terminalis line was made. All lines were interconnected., Results: Normal sinus rhythm (SR) was restored in all patients at the end of the procedure. All patients discontinued medication during the follow-up. After a blanking period of 6 months, all patients presented stable SR. At a mean of 4.07 ± 1.8 years, normal SN reduction and chronotropic response to exercise were present. In the 51 patients initially diagnosed with POTS, no syncope occurred. During follow-up, pericarditis was the most common complication (121 patients: 47%), with complete resolution in all cases. Pneumothorax was observed in 5 patients (1.9%), only 3 (1.1%) required surgical drainage. Five patients (1.9%) required a dual-chamber pacemaker due to sinus arrest > 5 s., Conclusions: Preliminary results of this multicenter experience with a novel SN sparing hybrid ablation of IST/POTS, using surgical thoracoscopic video-assisted epicardial ablation combined with simultaneous endocardial 3D mapping may prove to be an efficient and safe therapeutic option in patients with symptomatic drug-resistant IST and POTS. Importantly, in our study, all patients had a complete resolution of the symptoms and restored normal SN activity., (© 2021. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
9. Comparison between superior vena cava ablation in addition to pulmonary vein isolation and standard pulmonary vein isolation in patients with paroxysmal atrial fibrillation with the cryoballoon technique.
- Author
-
Overeinder I, Osório TG, Călburean PA, Bisignani A, Bala G, Sieira J, Ströker E, Al Houssari M, Mojica J, Boveda S, Paparella G, Brugada P, de Asmundis C, and Chierchia GB
- Subjects
- Humans, Retrospective Studies, Treatment Outcome, Vena Cava, Superior diagnostic imaging, Vena Cava, Superior surgery, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation, Cryosurgery, Pulmonary Veins diagnostic imaging, Pulmonary Veins surgery
- Abstract
Background: Paroxysmal atrial fibrillation (PAF) can be triggered by non-pulmonary vein foci, like the superior vena cava (SVC). The latter is correlated with improved result in terms of freedom from atrial tachycardias (ATs), when electrical isolation of this vessel utilizing radiofrequency energy (RF) is achieved., Objectives: Evaluate the clinical impact, in patients with PAF, of the SVC isolation (SVCi) in addition to ordinary pulmonary vein isolation (PVI) by means of the second-generation cryoballoon (CB) METHODS: A total of 100 consecutive patients that underwent CB ablation for PAF were retrospectively selected. Fifty consecutive patients received PVI followed by SVCi by CB application, and the following 50 consecutive patients received standard PVI. All patients were followed 12 months., Results: The mean time to SVCi was 36.7 ± 29.0 s and temperature at SVC isolation was - 35 (- 18 to - 40) °C. Real-time recording (RTR) during SVCi was observed in 42 (84.0%) patients. At the end of 12 months of follow-up, freedom from ATs was achieved in 36 (72%) patients in the PVI only group and in 45 (90%) patients of the SVC and PV isolation group (Fisher's exact test p = 0.039, binary logistic regression: p = 0.027, OR = 0.28, 95%CI = 0.09-0.86). In survival analysis, SVC and PV isolation group was also associated with improved freedom from ATs (log-rank test: p = 0.017, Cox regression: p = 0.026, HR = 0.31, 95%CI = 0.11-0.87)., Conclusion: Superior vena cava isolation with the CB in addition to PVI might improve freedom from ATs if compared to PVI alone at 1-year follow-up., (© 2021. The Author(s).)
- Published
- 2021
- Full Text
- View/download PDF
10. Substrate mapping of the left atrium in persistent atrial fibrillation: spatial correlation of localized complex conduction patterns in global charge-density maps to low-voltage areas in 3D contact bipolar voltage maps.
- Author
-
Chierchia GB, Sieira J, Vanderper A, Osorio TG, Bala G, Stroker E, Brugada P, Al Houssari M, Cecchini F, Mojica J, Overeinder I, Bisignani A, Mitraglia V, Boveda S, Paparella G, and de Asmundis C
- Subjects
- Electrophysiologic Techniques, Cardiac, Heart Atria diagnostic imaging, Heart Atria surgery, Heart Rate, Humans, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation
- Abstract
Purpose: This study aimed to investigate the spatial relationship between low-voltage areas (LVAs) in bipolar voltage mapping (BVM) and localized complex conduction (LCC)-cores in a global, non-contact, charge-density-based imaging, and mapping system (AcM)., Methods: Patients with history of index PVI for PsAF and scheduled for a repeat ablation procedure for recurrence of the same arrhythmia were enrolled between August 2018 and February 2020. All patients underwent both substrate mappings of the left atrium (LA) with the CARTO 3D map-ping system and with AcM., Results: Ten patients where included in our analysis. All presented with persistency of PVI in all veins at the moment of repeat procedure. There was no linear relationship in BVM maps between SR and CSd (correlation coefficient 0.31 ± 0.15), SR and CSp (0.36 ± 0.12) and CSd and CSp (0.43 ± 0.10). The % overlap of localized irregular activation (LIA), localized rotational activation (LRA) and Focal (F) regions with LVA was lower at 0.2 mV compared to 0.5 mV (4.97 ± 7.39%, 3.27 ± 5.25%, 1.09 ± 1.92% and 12.59 ± 11.81%, 7.8 ± 9.20%, 4.62 ± 5.27%). Sensitivity and specificity are not significantly different when comparing composite maps with different LVA cut-offs. AURC was 0.46, 0.48, and 0.39 for LIA, LRA, and Focal, respectively., Conclusion: Due to wave front direction dependency, LVAs mapped with BVM in sinus rhythm and during coronary sinus pacing only partially overlap in patients with PsAF. LCC-cores mapped during PsAF partially co-localize with LVAs., (© 2021. The Author(s).)
- Published
- 2021
- Full Text
- View/download PDF
11. Posterior box isolation as an adjunctive ablation strategy with the second-generation cryoballoon for paroxysmal atrial fibrillation: a comparison with standard cryoballoon pulmonary vein isolation.
- Author
-
Bisignani A, Overeinder I, Kazawa S, Iacopino S, Cecchini F, Miraglia V, Osório TG, Boveda S, Bala G, Mugnai G, Monaco C, Ströker E, Brugada P, Sieira J, Galli A, de Asmundis C, and Chierchia GB
- Subjects
- Humans, Recurrence, Treatment Outcome, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation, Cryosurgery, Pulmonary Veins diagnostic imaging, Pulmonary Veins surgery
- Abstract
Purpose: The purpose of the study was to evaluate the impact of left atrial posterior wall isolation (LAPWI) in addition to pulmonary vein isolation (PVI) vs PVI alone, performed using CB-A, in patients with PAF on a midterm follow-up of 12 months., Methods: Eighty consecutive patients indicated to index cryoballoon ablation (CB-A) for the treatment of drug resistant PAF were included. The first 50 (62.5%) underwent PVI only, and the following 30 patients (37.5%) underwent LAPWI + PVI., Results: Acute isolation was achieved in all PVs in both groups. The LAPW was successfully isolated in 29 out of 30 (97%) patients; in the remaining patient, adjunct radiofrequency ablation was required. The total procedure time and the mean fluoroscopy time were significantly shorter in patients who underwent PV isolation only (p < 0.001). The freedom from atrial fibrillation (AF) at 12 months was not significantly different between the 2 groups (LAPW + PVI = 90% vs PVI = 88%) (log-rank p = 0.816)., Conclusion: LAPW ablation in addition to PVI by the means of CB-A does not seem to reduce the risk of AF recurrence if compared with the standard PVI on a midterm follow-up of 12 months., (© 2020. Springer Science+Business Media, LLC, part of Springer Nature.)
- Published
- 2021
- Full Text
- View/download PDF
12. Long-term clinical outcomes after single freeze cryoballoon ablation for paroxysmal atrial fibrillation: a 5-year follow-up.
- Author
-
Mugnai G, Paparella G, Overeinder I, Ströker E, Sieira J, Bisignani A, Iacopino S, Boveda S, Beckers S, Umbrain V, Bala G, Brugada P, de Asmundis C, and Chierchia GB
- Subjects
- Follow-Up Studies, Humans, Male, Middle Aged, Recurrence, Retrospective Studies, Treatment Outcome, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation, Cryosurgery, Pulmonary Veins diagnostic imaging, Pulmonary Veins surgery
- Abstract
Background: The second-generation cryoballoon ablation (CB-A) has been proven to be safe and effective for pulmonary vein (PV) isolation. Little is known regarding the long-term outcome following CB-A ablation for paroxysmal atrial fibrillation (AF). The aim of the study was to evaluate the freedom from atrial arrhythmias during a 5-year follow-up period among consecutive patients having undergone PV isolation with the CB-A for paroxysmal AF METHODS AND RESULTS: A total of 208 consecutive patients having undergone index PV isolation using CB-A (138 males, 66%; mean age 59.0 ± 12.6 years) were included in our retrospective analysis. Follow-up was based on outpatient clinic visits including Holter electrocardiograms. Recurrence of atrial tachyarrhythmias was defined as a symptomatic or documented episode of > 30 s. At a median follow-up of 62 months, freedom from atrial arrhythmias after a single procedure was achieved in 57.2% of patients. Multivariate analysis demonstrated that obesity, left atrial diameter, and duration of symptoms before AF ablation were independent predictors of ATas recurrences. Major complications occurred in 2.4% of patients., Conclusions: The present study found a 5-year single-procedure success rate of 57.2% following CB-A ablation procedure. Obesity, higher LA dimensions, and longer duration of symptoms before ablation independently predicted the outcome.
- Published
- 2021
- Full Text
- View/download PDF
13. Correction to: Novel noncontact charge density map in the setting of post-atrial fibrillation atrial tachycardias: first experience with the Acutus SuperMap Algorithm.
- Author
-
Ramak R, Chierchia GB, Paparella G, Monaco C, Miraglia V, Cecchini F, Bisignani A, Mojica J, Al Housari M, Sofianos D, Kazawa S, Overeinder I, Bala G, Ströker E, Sieira J, Osorio TG, Brugada P, and de Asmundis C
- Published
- 2021
- Full Text
- View/download PDF
14. Novel noncontact charge density map in the setting of post-atrial fibrillation atrial tachycardias: first experience with the Acutus SuperMap Algorithm.
- Author
-
Ramak R, Chierchia GB, Paparella G, Monaco C, Miraglia V, Cecchini F, Bisignani A, Mojica J, Al Housari M, Sofianos D, Kazawa S, Overeinder I, Bala G, Ströker E, Sieira J, Osorio TG, Brugada P, and de Asmundis C
- Subjects
- Algorithms, Humans, Tachycardia surgery, Treatment Outcome, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation, Tachycardia, Supraventricular diagnostic imaging, Tachycardia, Supraventricular surgery
- Abstract
Purpose: The purpose of this study was to evaluate the safety and feasibility of the new high-resolution mapping algorithm SuperMap (Acutus Medical, CA, USA) in identifying and guiding ablation in the setting of regular atrial tachycardias following index atrial fibrillation (AF) ablation., Methods: Seven consecutive patients who underwent a radiofrequency catheter ablation guided by the novel noncontact charge density (CD) SuperMap for atrial tachycardia were prospectively enrolled in our study., Results: Arrhythmogenic substrate was identified in all seven patients. Mean number of EGM per map was 5859.7 ± 4348.5 points. Three patients (43%) exhibited focal tachycardia mechanisms in the left atrium, alternating from anteroseptal right superior pulmonary vein (RSPV), posterior in proximity of left inferior pulmonary vein (LIPV), and interarial septum in proximity of fossa ovalis, respectively. Four patients exhibited macroreentrant mechanism. In 3 of these patients, SuperMap detected mitral isthmus-dependent flutters with tachycardia cycle lengths of 240, 270 and 420 ms, respectively. In one patient, the mechanism was a macroreentrant tachycardia with the critical isthmus located between the crista terminalis and atriotomy. The mean ablation time (min) was 18.2 ± 12.5 and the mean procedural duration time was 56.4 ± 12.1 min. No minor or major complications occurred., Conclusion: The novel high-resolution mapping algorithm SuperMap proved to be safe, fast, and feasible in identifying and guiding ablation in the setting of regular atrial tachycardias following index AF ablation.
- Published
- 2021
- Full Text
- View/download PDF
15. Safety and feasibility of electrical isolation of the superior vena cava in addition to pulmonary vein ablation for paroxysmal atrial fibrillation using the cryoballoon: lessons from a prospective study.
- Author
-
Iacopino S, Osório TG, Filannino P, Artale P, Sieira J, Ströker E, Bala G, Overeinder I, Hacioglu E, Călburean PA, Paparella G, Brugada P, de Asmundis C, and Chierchia GB
- Subjects
- Feasibility Studies, Humans, Prospective Studies, Treatment Outcome, Vena Cava, Superior diagnostic imaging, Vena Cava, Superior surgery, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Catheter Ablation, Cryosurgery, Pulmonary Veins diagnostic imaging, Pulmonary Veins surgery
- Abstract
Purpose: The purpose of this study was to evaluate the feasibility and safety of superior vena cava (SVC) isolation in addition to standard pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation., Methods: Thirty-seven consecutive patients that underwent CB ablation for paroxysmal atrial fibrillation (PAF) were prospectively enrolled in our study. After PVI the SVC was mapped for potentials. If the SVC exhibited electrical activity, isolation was achieved performing a single 180-s balloon application., Results: Regarding SVC isolation, 180-s freeze in the SVC could be completed in 32 (86.4%) patients, and 5 patients had at least 120 s of freezing application (13.5%). Real-time recording during SVC isolation was observed in 30 (81.0%) patients. The mean time to isolation was 36.9 ± 28.7 s and the temperature at isolation was - 33 (- 15 to - 40) °C. No cases developed persistent phrenic nerve palsy (PNP) or any other complication., Conclusions: Superior vena cava isolation proved to be safe and feasible with the second generation cryoballoon in a prospective series of patients affected by PAF.
- Published
- 2021
- Full Text
- View/download PDF
16. Long-term outcome after second-generation cryoballoon ablation for paroxysmal atrial fibrillation - a 3-years follow-up.
- Author
-
Takarada K, Overeinder I, de Asmundis C, Stroker E, Mugnai G, de Regibus V, Moran D, Coutino-Moreno H, Abugattas JP, Choudhury R, Ruggiero D, Paparella G, Iacopino S, Brugada P, and Chierchia GB
- Subjects
- Aged, Atrial Fibrillation diagnosis, Equipment Design, Equipment Failure Analysis, Female, Humans, Male, Retrospective Studies, Treatment Outcome, Atrial Fibrillation surgery, Catheter Ablation instrumentation, Catheter Ablation methods, Cryosurgery instrumentation, Cryosurgery methods, Heart Conduction System surgery, Pulmonary Veins surgery
- Abstract
Background: The second-generation cryoballoon (cryoballoon Advance; CB-A) offers excellent outcomes on the mid-term follow-up. To the best of our knowledge, little is known regarding the long-term outcome after CB-A ablation for paroxysmal atrial fibrillation (AF)., Objective: The aim of the study was to evaluate the freedom from recurrence of AF during a 3-year follow-up period, among consecutive patients having undergone pulmonary vein isolation (PVI) with the CB-A for paroxysmal AF (PAF)., Methods: Consecutive patients with drug-resistant PAF who underwent PVI using CB-A as an index procedure formed the study group. Patients were evaluated with holter ECG recordings at 1, 3, 6 and 12 months and subsequent follow-up was biannual or based on the clinical status and at the physician discretion., Results: Seventy-six consecutive patients were enrolled. Of these patients, 6 were excluded because of lack of long-term follow-up. A total of 70 patients [44 male (63%); mean age 57.9 ± 14.5 years] with a mean follow-up of 38.0 ± 7.4 months were finally included. In total, 278 PVs were depicted on the pre-procedural CT scan. All PVs (100%) could be isolated with the CB-A only. The freedom from AF without antiarrhythmic drug (AADs) after a single procedure was 71.5% of patients at a mean 38.0 ± 7.4 months follow-up. If including repeat procedures, 80% of the patients were free from AF recurrence after 1.11 ± 0.32 procedures without AADs., Conclusion: The second-generation cryoballoon offers long-term freedom from PAF in 71.5% of treated patients with a single procedure without AADs on a 3-year follow-up period.