1. Is citrate theophylline adenosine dipyridamole (CTAD) better than citrate to survey unfractionated heparin treatment? Has delayed centrifugation a real impact on this survey?
- Author
-
Marie Hélène Chrétien, Paul Billoir, Virginie Barbay, Thomas Clavier, Véronique Le Cam Duchez, Arnaud Guilbert, Marielle Fresel, Christophe Girault, and Caroline Abriou
- Subjects
Time Factors ,Phosphodiesterase Inhibitors ,medicine.drug_class ,Centrifugation ,030204 cardiovascular system & hematology ,Pharmacology ,Thrombin time ,03 medical and health sciences ,0302 clinical medicine ,Theophylline ,Humans ,Medicine ,Citrates ,030212 general & internal medicine ,medicine.diagnostic_test ,Heparin ,business.industry ,Anticoagulant ,Anticoagulants ,Dipyridamole ,Hematology ,Adenosine ,Blood Preservation ,Blood Coagulation Tests ,Drug Monitoring ,Cardiology and Cardiovascular Medicine ,business ,Platelet factor 4 ,circulatory and respiratory physiology ,medicine.drug - Abstract
Unfractionated heparin (UFH) is the main anticoagulant used in intensive care unit. The anticoagulant effect is monitored by activated partial thrombin time (aPTT) and anti-Xa activity (anti-Xa) measurement. However, delayed centrifugation induces platelet factor 4 (PF4) release and anti-Xa decrease. Several studies have concluded that aPTT and anti-Xa measurement should be performed within 2 h in citrated anticoagulant but may be delayed longer in Citrate Theophylline Adenosine and Dypiridamol (CTAD) anticoagulant. The objective of this study was to compare the stability of both aPTT and anti-Xa in citrate and CTAD samples, and to determine the effect of delayed centrifugation on both aPTT, anti-Xa results, and PF4 release in citrate samples only. aPTT and anti-Xa were measured in citrate and CTAD anticoagulant samples from 93 patients. Delayed centrifugation was performed in citrate samples from 31 additional patients, with hourly aPTT and anti-Xa measurement from 1 to 6 h. In 14 of these last patients, PF4 release was also evaluated with Human CXCL4/PF4 Quantikine ELISA Kit. We observed a significant correlation between citrate and CTAD anticoagulant for aPTT (r2 = 0.94) and anti-Xa (r2 = 0.95). With Bland–Altman correlation, a minor bias was observed for anti-Xa (− 0.025 ± 0.041). Delayed centrifugation in citrated anticoagulant showed an excellent concordance from 1 to 4 h for aPTT (− 4.0 ± 5.3 s) and anti-Xa (1.10−9 ± 0.058 UI/ml) measurements. Moreover, PF4 release was not different between 1 h (31.5 ± 14.7 ng/ml) and 4 h (33.8 ± 11.8 ng/ml). We have demonstrated that anti-Xa measurement for unfractionated heparin should be done 4 h in citrated plasma and that CTAD was not better than citrate. However, these initial findings require confirmation using other aPTT and calibrated anti-Xa assays.
- Published
- 2019
- Full Text
- View/download PDF