1. Diameter Changes in Traumatic Aortic Injury: Implications for Stent-Graft Sizing.
- Author
-
Berger T, Voetsch A, Alaloh D, Kreibich M, Krombholz-Reindl P, Winkler A, Rylski B, Wolfgruber T, Beyersdorf F, Siepe M, Seitelberger R, Czerny M, and Gottardi R
- Subjects
- Aorta surgery, Aorta, Thoracic diagnostic imaging, Aorta, Thoracic injuries, Aorta, Thoracic surgery, Aortography methods, Blood Vessel Prosthesis, Humans, Retrospective Studies, Stents, Treatment Outcome, Blood Vessel Prosthesis Implantation adverse effects, Blood Vessel Prosthesis Implantation methods, Endovascular Procedures adverse effects, Endovascular Procedures methods, Vascular System Injuries diagnostic imaging, Vascular System Injuries etiology, Vascular System Injuries surgery
- Abstract
Objectives: The aim of this study was to compare aortic diameters from admission computed tomography angiography (CTA) scans to postoperative aortic diameters in patients with traumatic aortic injury (TAI) and evaluate the influence of substantial blood loss on aortic diameter., Methods: The aortic databases of two tertiary university centers were retrospectively screened for patients with TAI between February 2002 and February 2019. Concomitant organ injuries, bone fractures, blood loss, and clinical outcomes were evaluated. Aortic diameters were measured in CTA upon admission and were compared with the CTA before discharge at three different aortic levels (mid-ascending, 5 cm distal to the end of the stent graft, and at the celiac trunk level)., Results: We identified 45 patients, aged 43 (first quartile; third quartile [26; 55]) years with a TAI treated by thoracic endovascular aortic repair. The most frequent cause of TAI was a car accident ( n = 24). Concomitant injuries were seen in all but one patient. Bone and pelvic fractures were seen in 40 (89%) and 15 (33%) patients, respectively. Type III aortic injury was present in 25 patients (56%). Increase of aortic diameter after stabilization was +1.7 mm (-0.6 mm; 2.5 mm; p = 0.004) at the mid-ascending aorta, +2.1 mm (0.2 mm; 3.8 mm; p < 0.001) 5 cm distal to the stent graft, and +1.5 mm (0.5 mm; 3.2 mm; p < 0.001) at the celiac trunk level., Conclusion: In patients with TAI, the aortic diameter is significantly reduced as compared with the aortic diameter at discharge. The reduction of aortic diameter might be caused by hemorrhagic shock and should be kept in mind for appropriate stent-graft sizing., Competing Interests: Disclosure The authors report no conflicts of interest in this work., (Thieme. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF